Skip to content

Magnetic Unit Converter (Tesla to Gauss)

Convert magnetic units: tesla to gauss, oersted to A/m, weber to maxwell, emu/cm³ to A/m and emu to A·m², with the vacuum B ↔ H equivalent.

Calculator Details

1 T =10,000 GSee results ↓

Flux density B (tesla, gauss), field strength H (A/m, oersted), flux (weber, maxwell), magnetisation M or magnetic moment

The amount to convert, in the From unit

Your Results

1 T = 10,000 G

1 T =

10,000 G

Flux density B (tesla, gauss)

H that gives this B in vacuum

795,774.72 A/m

10,000 Oe (H = B ÷ μ₀)

Tesla and gauss measure flux density B; A/m and oersted measure field strength H. They are only equal (1 G ↔ 1 Oe) in a vacuum, and in air to within 0.00004%. Inside iron or a magnet they differ.

1 T = 10,000 G

Detailed Breakdown

1 T in every unit of flux density b
UnitValue
Tesla (from)1 T
Millitesla1,000 mT
Microtesla1,000,000 µT
Nanotesla1,000,000,000 nT
Gamma1,000,000,000 γ
Kilogauss10 kG
Gauss (your answer)10,000 G
Milligauss10,000,000 mG

How This Calculator Works

How it's calculated

1 G = 10⁻⁴ T · 1 γ = 1 nT · in vacuum H = B ÷ μ₀

value in To = value × (size of From) ÷ (size of To)

Your numbers: 1 T = 1 T, which is 10,000 G. The SI ↔ cgs factors are exact definitions (NIST SP 811), so the only rounding is to 6 significant figures. The vacuum equivalent uses μ₀ = 1.25663706127e-6 N/A² (CODATA 2022), measured rather than exact since the 2019 SI revision.

Frequently Asked Questions

How do I convert tesla to gauss?

Multiply by 10,000: 1 T = 10,000 G, 1 mT = 10 G and 1 µT = 0.01 G (10 mG). To go from gauss to tesla, divide by 10,000. A fridge magnet is about 5 mT (50 G), an MRI scanner 1.5 or 3 T (15,000 or 30,000 G).

How strong is the Earth’s magnetic field?

Roughly 25 to 65 µT (0.25 to 0.65 G) at the surface, weakest near the equator and strongest near the magnetic poles. Across most of Canada it is about 50 to 60 µT. Geophysicists often quote it in nanotesla, also called gamma: 55,000 nT.

How do I convert oersted to A/m?

Multiply by 1000/(4π), about 79.5775: 1 Oe = 79.58 A/m and 1 kOe = 79.58 kA/m. The 4π appears because the cgs system and the SI define the field strength H with different factors (the SI is "rationalised").

Is a gauss the same as an oersted?

They have the same size in a vacuum (and almost exactly in air), which is why the units are often mixed up, but they measure different quantities: the gauss measures flux density B, the oersted field strength H. In SI the two are linked by the magnetic constant, B = μ₀H, with μ₀ = 1.25663706127e-6 N/A². Inside a magnetic material B and H differ by its permeability.

What is the difference between weber and tesla?

The weber measures total magnetic flux through a surface; the tesla measures flux per square metre (1 T = 1 Wb/m²). Likewise in cgs, the maxwell is total flux and the gauss is maxwells per square centimetre. 1 Wb = 100,000,000 Mx.

How do I convert emu/cm³ to A/m?

Multiply by 1,000: 1 emu/cm³ = 1,000 A/m = 1 kA/m of magnetisation. Many datasheets give 4πM in gauss instead; multiply that by 1000/(4π) to get A/m. A neodymium magnet with a remanence of about 1.3 T has a magnetisation of about 1,000 kA/m.

Why does μ₀ have a measured value now?

Before 2019, μ₀ was defined as exactly 4π × 10⁻⁷ N/A². The 2019 SI revision fixed the elementary charge instead, so μ₀ became a measured constant. CODATA’s value differs from 4π × 10⁻⁷ by about one part in ten billion, far too small to matter for unit conversions.

Included: exact SI ↔ Gaussian-cgs (emu) conversions within flux density (T, G, γ), field strength (A/m, Oe), flux (Wb, Mx), magnetisation (A/m, emu/cm³, 4πM) and magnetic moment (A·m², emu), from NIST SP 811 Appendix B and IEEE/ASTM SI 10, and the vacuum B ↔ H equivalent with μ₀ from CODATA 2022. Left out: B ↔ H inside a material (it needs the material's permeability or B–H curve), mass and molar susceptibility, energy product (MGOe ↔ kJ/m³), the older electrostatic (esu) units, and field calculations from currents or coils (see the magnetic field calculator). Results are rounded to 6 significant figures.

Magnetic Unit Converter: Tesla to Gauss, Oersted to A/m and More

By FindMySum · Last reviewed

A magnetic unit converter moves a measurement between the SI units (tesla, ampere per metre, weber) and the older Gaussian-cgs units (gauss, oersted, maxwell, emu) that still fill physics papers, magnet datasheets and EMF meter displays. Magnetism has several distinct quantities, and confusing them is the usual source of wrong answers, so this page asks for the quantity first and converts within it.

The five quantities

QuantitySymbolSI unitcgs unitExact relation
Flux densityBtesla (T)gauss (G)1 G = 10⁻⁴ T
Field strengthHampere per metre (A/m)oersted (Oe)1 Oe = 1000/(4π) A/m ≈ 79.5775 A/m
Magnetic fluxΦweber (Wb)maxwell (Mx)1 Mx = 10⁻⁸ Wb
MagnetisationMampere per metre (A/m)emu/cm³1 emu/cm³ = 1000 A/m
Magnetic momentmampere square metre (A·m²)emu1 emu = 10⁻³ A·m²

All of these factors are exact, as listed in NIST Special Publication 811 and the IEEE/ASTM SI 10 metric practice standard. The tesla is one weber per square metre; the gauss is one maxwell per square centimetre. A nanotesla is also called a gamma (γ) in geophysics.

Where the 4π comes from

The SI is a "rationalised" system: its equations for magnetism put the factor of 4π in the formulas for spheres and points, so it disappears from the formulas for straight wires and flat sheets. The Gaussian system does the opposite. The result is that converting field strength or magnetisation between the two systems brings in a 4π:

  • 1 Oe = 1000/(4π) A/m = 79.5775 A/m
  • 1 A/m = 4π/1000 Oe = 0.0125664 Oe

Flux density and flux convert by powers of ten only, because the tesla and the gauss are both defined from the same physical force, just measured in different base units.

B is not H

Flux density B and field strength H are related by the material they are in. In SI:

B = μ₀ (H + M)

where μ₀ is the magnetic constant. In a vacuum M is zero, so B = μ₀H. In cgs the same relation is B = H + 4πM, and in a vacuum B = H, which is why 1 G and 1 Oe are numerically the same in empty space. In air they agree to better than one part in a million. Inside iron, steel or a permanent magnet, B and H can differ by a factor of thousands, and converting one to the other needs the material's permeability or its B–H curve. This page gives the vacuum equivalent and labels it as such.

Since the 2019 revision of the SI, μ₀ is a measured value rather than exactly 4π × 10⁻⁷ N/A². The CODATA 2022 value is 1.25663706127 × 10⁻⁶ N/A², which differs from the old exact value by about one part in ten billion. It changes nothing in practical conversions, but the page uses the current value.

Worked example: the default

The page opens on 1 tesla to gauss.

  1. 1 G = 10⁻⁴ T, so 1 T = 1 ÷ 10⁻⁴ = 10,000 G.
  2. The same flux density is 1,000 mT, 10 kG or 1,000,000,000 γ.
  3. In a vacuum, the field strength that produces it is H = B ÷ μ₀ = 1 ÷ 1.25663706127 × 10⁻⁶ = 795,775 A/m, which is 10,000 Oe.

Worked example: a magnet datasheet

A sintered neodymium magnet is listed with a coercivity of 12 kOe. In SI:

  1. 12 kOe = 12,000 Oe.
  2. 12,000 × 79.5775 = 954,930 A/m, or about 955 kA/m.

Datasheets from different regions mix the two systems freely, so converting everything to one system before comparing grades avoids mistakes.

Typical values

SourceFlux density
Earth's field in southern Canadaabout 50–55 µT (0.50–0.55 G)
Field near household wiringabout 0.1–1 µT (1–10 mG)
Fridge magnet surfaceabout 5–10 mT (50–100 G)
Neodymium magnet faceabout 0.2–0.5 T
MRI scanner1.5 T or 3 T

These are typical orders of magnitude for context, not measurements.

What this converter does not do

It does not convert between quantities (gauss to amperes, tesla to webers without an area, B to H inside a material), mass or molar susceptibility, or the energy product of magnets (MGOe to kJ/m³). It does not calculate the field from a current, a coil or a magnet's shape; for that, use the magnetic field calculator. For volts, ohms, farads and henries, use the electrical unit converter, and to move any value between SI prefixes, the metric prefix converter.

Precision

The SI ↔ cgs factors are exact, π is carried to 20 significant digits and the arithmetic is decimal, so the only rounding is to 6 significant figures in the displayed result. Negative values are allowed, because a field component along an axis can point either way.

More questions

How many gauss is a strong magnet?

A typical fridge magnet produces about 50 to 100 G (5 to 10 mT) at its surface. A small neodymium magnet reaches 2,000 to 5,000 G (0.2 to 0.5 T) at its face, and the material inside has a remanence around 12,000 to 14,000 G (1.2 to 1.4 T). Hospital MRI scanners run at 15,000 or 30,000 G (1.5 or 3 T).

What unit do compasses and magnetometers use?

Phone magnetometers and most geophysical instruments report microtesla or nanotesla. Older survey work and some EMF meters use milligauss; 1 mG = 0.1 µT = 100 nT. Aeromagnetic surveys often use the gamma, which is exactly one nanotesla.

What is the cgs system?

The centimetre-gram-second system, used in physics before the SI took over and still common in magnetism research. Its electromagnetic version, Gaussian or emu units, gives the gauss, oersted, maxwell and emu. The SI equivalents are the tesla, ampere per metre, weber and ampere square metre.

Can I convert gauss to amperes?

Not directly: a gauss is a flux density and an ampere is a current. Working out the field a current produces needs the geometry (a straight wire, a loop, a coil), which is what the magnetic field calculator does. This page converts units of the same quantity only.

Why do magnet datasheets give 4πM?

In cgs units B = H + 4πM, so 4πM in gauss adds directly to the field and the flux density. Quoting magnetisation that way lets designers compare it with B and H in the same unit. Multiply 4πM in gauss by 1000/(4π) to get magnetisation in A/m.

Sources

This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.

Spotted a wrong result or a bug? Report a problem

May we count your visits with Invoker Analytics? It keeps a random visitor number in your browser. Your calculator inputs are never sent. Privacy policy