Skip to content

Radiation Converter

Convert radiation units: sieverts and rem, grays and rad, becquerels and curies, roentgens and C/kg, with dose rates and Canadian background and dose-limit context.

Calculator Details

1 rem =10 mSvSee results ↓

Equivalent/effective dose (Sv, rem), absorbed dose (Gy, rad), activity (Bq, Ci) or exposure (C/kg, R)

The amount to convert, in the From unit

Choose “per hour”, “per day” or “per year” for a dose rate (e.g. µSv/h from a meter)

Your Results

1 rem = 10 mSv

1 rem =

10 mSv

Equivalent / effective dose (Sv, rem)

Compared with background

5.55556 × a year

About 2,029.17 days of Canada’s average natural background

1 rem = 10 mSv

Detailed Breakdown

1 rem in every unit
UnitValue
Sievert (Sv)0.01 Sv
Millisievert (mSv) (your answer)10 mSv
Microsievert (µSv)10,000 µSv
Nanosievert (nSv)10,000,000 nSv
Rem (from)1 rem
Millirem (mrem)1,000 mrem
Microrem (µrem)1,000,000 µrem
Your dose in context (Canada)
ReferencemSvYour dose ÷ reference
Limit: Member of the public (not a nuclear energy worker), one calendar year110
Canadian average natural background (a year)1.85.55556
World average natural background (a year)2.44.16667
Limit: Pregnant nuclear energy worker (after informing the licensee), balance of the pregnancy42.5
Your dose (you)10
Limit: Nuclear energy worker, one-year dosimetry period500.2
Limit: Nuclear energy worker, five-year dosimetry period1000.1

Limits: Radiation Protection Regulations SOR/2000-203 ss. 13–14, for doses from licensed activities (not natural background or medical exposure). Background: CNSC. Context only, not a health risk estimate.

How This Calculator Works

How it's calculated

1 rem = 0.01 Sv · 1 rad = 0.01 Gy · 1 Ci = 3.7 × 10¹⁰ Bq · 1 R = 2.58 × 10⁻⁴ C/kg

value in To = value × (size of From) ÷ (size of To)

Your numbers: 1 rem = 0.01 Sv, which is 10 mSv. All factors are exact definitions (BIPM SI Brochure; NIST SP 811), so the only rounding is to 6 significant figures at the end.

Frequently Asked Questions

How do I convert rem to sieverts?

Divide by 100: 1 rem = 0.01 Sv = 10 mSv, and 1 mrem = 0.01 mSv = 10 µSv. Going the other way, 1 Sv = 100 rem and 1 mSv = 100 mrem. Rem is the older US unit; Canada and most of the world use sieverts.

What is the difference between a gray and a sievert?

Both are joules per kilogram, but they measure different things. The gray (Gy) is absorbed dose, the energy deposited in matter. The sievert (Sv) is equivalent or effective dose: the absorbed dose weighted for the type of radiation (alpha particles do about 20 times more harm per gray than X-rays) and, for effective dose, for the sensitivity of each organ. For X-rays and gamma rays 1 Gy gives 1 Sv, but not for alpha or neutrons.

How do I convert curies to becquerels?

Multiply by 3.7 × 10¹⁰: 1 Ci = 37 billion Bq = 37 GBq, 1 mCi = 37 MBq and 1 µCi = 37 kBq. One becquerel is one radioactive decay per second, and the curie was originally the activity of one gram of radium-226.

How much natural background radiation does a Canadian get?

About 1.8 mSv a year on average, according to the CNSC, compared with a world average of about 2.4 mSv. Most of it comes from radon in indoor air; the rest from cosmic rays, the ground and building materials, and naturally radioactive elements in food and in the body. It varies a lot by location and home.

What are the dose limits in Canada?

Under the Radiation Protection Regulations, a member of the public may receive at most 1 mSv a year from licensed nuclear activities. A nuclear energy worker’s limit is 50 mSv in a one-year period and 100 mSv over five years. These limits exclude natural background and medical exposure, which are managed separately.

How do I turn a dose rate in µSv/h into a yearly dose?

Multiply by the hours of exposure. Continuous exposure for a year is 8,766 hours (365.25 days), so 0.1 µSv/h all year is about 877 µSv, or 0.88 mSv. Choose “Per hour” and the calculator gives the per-day and per-year values; for part-time exposure, multiply the hourly rate by the hours actually spent there.

What is a roentgen?

An old unit of exposure: the amount of X-ray or gamma radiation that produces 2.58 × 10⁻⁴ coulombs of charge per kilogram of air. It is defined only for air and photons. As a rule of thumb, 1 R of gamma rays deposits about 8.77 mGy in air and roughly 9.5 mGy in soft tissue, but that is an approximation, not a unit conversion.

Can I convert becquerels to sieverts?

Not with a unit factor. Activity (Bq) counts decays; dose (Sv) depends on the radionuclide, its energy, how far away you are, how long you are exposed, and whether it is inhaled or swallowed. Converting needs nuclide-specific dose coefficients from the ICRP, which this converter does not include.

Included: exact unit conversions within equivalent/effective dose (Sv, rem), absorbed dose (Gy, rad), activity (Bq, Ci, dpm) and exposure (C/kg, R), from the BIPM SI Brochure and NIST SP 811; dose rates per hour, day and year; and, for sieverts, a comparison with Canada’s average natural background (CNSC) and the dose limits in the Radiation Protection Regulations (SOR/2000-203). This is a unit converter, not a dosimetry, shielding or health-risk tool: it does not convert grays or roentgens to sieverts (that needs radiation and tissue weighting factors), activity to dose, or account for decay. For a real exposure, contact your radiation safety officer, Health Canada or the CNSC.

Radiation Converter: Sieverts, Rem, Grays, Becquerels and Curies

By FindMySum · Last reviewed

A radiation converter changes a radiation measurement from one unit to another: rem to sieverts, rad to grays, curies to becquerels, roentgens to coulombs per kilogram. The units fall into four families that measure different things, so the first step is to choose the quantity. This page converts within each quantity using the exact definitions in the SI Brochure, handles dose rates per hour, day or year, and, for sieverts, puts your number next to Canada's average natural background and the legal dose limits, as context.

The four quantities

QuantityWhat it measuresSI unitOlder unitExact relation
Activityradioactive decays per secondbecquerel (Bq)curie (Ci)1 Ci = 3.7 × 10¹⁰ Bq
Exposureionisation of air by X- and gamma rayscoulomb per kilogram (C/kg)roentgen (R)1 R = 2.58 × 10⁻⁴ C/kg
Absorbed doseenergy deposited per kilogramgray (Gy) = 1 J/kgrad1 rad = 0.01 Gy
Equivalent / effective dosebiological effect of the dosesievert (Sv) = 1 J/kgrem1 rem = 0.01 Sv

The gray and the sievert are both joules per kilogram, but they are not interchangeable. A sievert weights the absorbed dose by the type of radiation (a radiation weighting factor of 1 for X-rays, gamma rays and electrons, 20 for alpha particles) and, for effective dose, by the sensitivity of each tissue. So this converter never turns grays into sieverts.

Worked example: the default

1 rem to millisieverts:

1 rem = 0.01 Sv = 0.01 × 1,000 mSv = 10 mSv.

That is about 5.6 times Canada's average yearly natural background of 1.8 mSv, and ten times the annual public dose limit for licensed activities. In the other direction, 1 mSv = 100 mrem, and the familiar "100 mrem a year" public limit in US documents is the same 1 mSv.

Activity: becquerels and curies

One becquerel is one decay per second, a tiny amount: a person's body contains several thousand becquerels of natural potassium-40 and carbon-14. The curie, based on one gram of radium, is enormous by comparison:

  • 1 Ci = 37 GBq
  • 1 mCi = 37 MBq (a typical medical imaging dose is a few hundred MBq, around 10 to 25 mCi)
  • 1 µCi = 37 kBq
  • 1 pCi = 0.037 Bq (US radon levels are quoted in pCi/L; 4 pCi/L is about 150 Bq/m³)

Disintegrations per minute (dpm) are also activity: 60 dpm = 1 Bq.

Dose rates

Meters show dose rates, usually µSv/h. Choose "per hour" (or per day, per year) to see the same rate in all three. A year of continuous exposure is 8,766 hours. For example, 0.5 µSv/h all year adds up to 4,383 µSv, about 4.4 mSv, or 2.4 times the Canadian average background. Most real exposures are not continuous, so multiply by the hours you actually spend there.

Canadian context

The Radiation Protection Regulations under the Nuclear Safety and Control Act set these effective dose limits for doses from licensed activities:

PersonPeriodLimit
Member of the publicone calendar year1 mSv
Nuclear energy workerone-year dosimetry period50 mSv
Nuclear energy workerfive-year dosimetry period100 mSv
Pregnant nuclear energy workerbalance of the pregnancy4 mSv

There are also equivalent dose limits for the lens of the eye, the skin and the hands and feet. Natural background and medical procedures are not counted against these limits. The CNSC puts the Canadian average natural background at about 1.8 mSv a year, much of it from radon at home.

These figures are context, not a risk estimate. Health effects depend on how the dose was received, and below about 100 mSv any increased cancer risk is too small to measure directly.

What this converter does not do

  • It does not convert activity (Bq) to dose (Sv): that depends on the radionuclide, distance, time and route of intake, and needs ICRP dose coefficients.
  • It does not convert roentgens or grays to sieverts.
  • It does not model shielding, decay over time or contamination.

For a real exposure or a reading that concerns you, contact your radiation safety officer, Health Canada or the CNSC.

More questions

Why are there so many radiation units?

Because there are four different quantities, and each had an older unit before the SI ones were adopted in 1975 and 1979. Activity (how many decays per second) moved from curies to becquerels; exposure (ionisation of air) from roentgens to coulombs per kilogram; absorbed dose from rad to gray; and equivalent dose from rem to sievert. The United States still uses the older units widely, Canada uses SI.

Is a millisievert a lot?

It is about what an average Canadian receives in seven months from natural background radiation (about 1.8 mSv a year), and it is the annual public dose limit for licensed nuclear activities. A chest X-ray is roughly 0.1 mSv and a CT scan of the abdomen around 10 mSv, though medical doses vary widely by machine and procedure.

Why do Geiger counters show µSv/h?

Most survey meters are calibrated to estimate the ambient dose equivalent rate from gamma rays, so they display microsieverts per hour. Typical outdoor readings in Canada are around 0.05 to 0.2 µSv/h. A reading in counts per minute (CPM) depends on the tube and can't be converted to µSv/h without the meter's calibration factor.

What is effective dose?

The sum over organs of the equivalent dose in each organ times a tissue weighting factor that reflects its sensitivity to cancer and hereditary effects. It turns an uneven exposure into a single whole-body number in sieverts, which is the quantity regulatory dose limits use.

Does this converter work for radiation from phones or Wi-Fi?

No. Phones, Wi-Fi and power lines emit non-ionising radiation, measured as power density (W/m²) or specific absorption rate (W/kg), under Health Canada's Safety Code 6. Sieverts, grays and becquerels describe ionising radiation from radioactive material and X-rays.

Sources

This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.

Spotted a wrong result or a bug? Report a problem

May we count your visits with Invoker Analytics? It keeps a random visitor number in your browser. Your calculator inputs are never sent. Privacy policy