A radiation converter changes a radiation measurement from one unit to another: rem to sieverts, rad to grays, curies to becquerels, roentgens to coulombs per kilogram. The units fall into four families that measure different things, so the first step is to choose the quantity. This page converts within each quantity using the exact definitions in the SI Brochure, handles dose rates per hour, day or year, and, for sieverts, puts your number next to Canada's average natural background and the legal dose limits, as context.
The four quantities
| Quantity | What it measures | SI unit | Older unit | Exact relation |
|---|---|---|---|---|
| Activity | radioactive decays per second | becquerel (Bq) | curie (Ci) | 1 Ci = 3.7 × 10¹⁰ Bq |
| Exposure | ionisation of air by X- and gamma rays | coulomb per kilogram (C/kg) | roentgen (R) | 1 R = 2.58 × 10⁻⁴ C/kg |
| Absorbed dose | energy deposited per kilogram | gray (Gy) = 1 J/kg | rad | 1 rad = 0.01 Gy |
| Equivalent / effective dose | biological effect of the dose | sievert (Sv) = 1 J/kg | rem | 1 rem = 0.01 Sv |
The gray and the sievert are both joules per kilogram, but they are not interchangeable. A sievert weights the absorbed dose by the type of radiation (a radiation weighting factor of 1 for X-rays, gamma rays and electrons, 20 for alpha particles) and, for effective dose, by the sensitivity of each tissue. So this converter never turns grays into sieverts.
Worked example: the default
1 rem to millisieverts:
1 rem = 0.01 Sv = 0.01 × 1,000 mSv = 10 mSv.
That is about 5.6 times Canada's average yearly natural background of 1.8 mSv, and ten times the annual public dose limit for licensed activities. In the other direction, 1 mSv = 100 mrem, and the familiar "100 mrem a year" public limit in US documents is the same 1 mSv.
Activity: becquerels and curies
One becquerel is one decay per second, a tiny amount: a person's body contains several thousand becquerels of natural potassium-40 and carbon-14. The curie, based on one gram of radium, is enormous by comparison:
- 1 Ci = 37 GBq
- 1 mCi = 37 MBq (a typical medical imaging dose is a few hundred MBq, around 10 to 25 mCi)
- 1 µCi = 37 kBq
- 1 pCi = 0.037 Bq (US radon levels are quoted in pCi/L; 4 pCi/L is about 150 Bq/m³)
Disintegrations per minute (dpm) are also activity: 60 dpm = 1 Bq.
Dose rates
Meters show dose rates, usually µSv/h. Choose "per hour" (or per day, per year) to see the same rate in all three. A year of continuous exposure is 8,766 hours. For example, 0.5 µSv/h all year adds up to 4,383 µSv, about 4.4 mSv, or 2.4 times the Canadian average background. Most real exposures are not continuous, so multiply by the hours you actually spend there.
Canadian context
The Radiation Protection Regulations under the Nuclear Safety and Control Act set these effective dose limits for doses from licensed activities:
| Person | Period | Limit |
|---|---|---|
| Member of the public | one calendar year | 1 mSv |
| Nuclear energy worker | one-year dosimetry period | 50 mSv |
| Nuclear energy worker | five-year dosimetry period | 100 mSv |
| Pregnant nuclear energy worker | balance of the pregnancy | 4 mSv |
There are also equivalent dose limits for the lens of the eye, the skin and the hands and feet. Natural background and medical procedures are not counted against these limits. The CNSC puts the Canadian average natural background at about 1.8 mSv a year, much of it from radon at home.
These figures are context, not a risk estimate. Health effects depend on how the dose was received, and below about 100 mSv any increased cancer risk is too small to measure directly.
What this converter does not do
- It does not convert activity (Bq) to dose (Sv): that depends on the radionuclide, distance, time and route of intake, and needs ICRP dose coefficients.
- It does not convert roentgens or grays to sieverts.
- It does not model shielding, decay over time or contamination.
For a real exposure or a reading that concerns you, contact your radiation safety officer, Health Canada or the CNSC.
More questions
Why are there so many radiation units?
Because there are four different quantities, and each had an older unit before the SI ones were adopted in 1975 and 1979. Activity (how many decays per second) moved from curies to becquerels; exposure (ionisation of air) from roentgens to coulombs per kilogram; absorbed dose from rad to gray; and equivalent dose from rem to sievert. The United States still uses the older units widely, Canada uses SI.
Is a millisievert a lot?
It is about what an average Canadian receives in seven months from natural background radiation (about 1.8 mSv a year), and it is the annual public dose limit for licensed nuclear activities. A chest X-ray is roughly 0.1 mSv and a CT scan of the abdomen around 10 mSv, though medical doses vary widely by machine and procedure.
Why do Geiger counters show µSv/h?
Most survey meters are calibrated to estimate the ambient dose equivalent rate from gamma rays, so they display microsieverts per hour. Typical outdoor readings in Canada are around 0.05 to 0.2 µSv/h. A reading in counts per minute (CPM) depends on the tube and can't be converted to µSv/h without the meter's calibration factor.
What is effective dose?
The sum over organs of the equivalent dose in each organ times a tissue weighting factor that reflects its sensitivity to cancer and hereditary effects. It turns an uneven exposure into a single whole-body number in sieverts, which is the quantity regulatory dose limits use.
Does this converter work for radiation from phones or Wi-Fi?
No. Phones, Wi-Fi and power lines emit non-ionising radiation, measured as power density (W/m²) or specific absorption rate (W/kg), under Health Canada's Safety Code 6. Sieverts, grays and becquerels describe ionising radiation from radioactive material and X-rays.
Sources
- BIPM, The International System of Units (SI Brochure), 9th edition (2019)
- NIST Special Publication 811: Guide for the Use of the International System of Units, Appendix B
- Radiation Protection Regulations (SOR/2000-203), sections 13 and 14
- Canadian Nuclear Safety Commission: Natural background radiation