Skip to content

Reverberation Time Calculator

Estimate a room’s RT60 reverberation time with the Sabine and Eyring formulas from its size and surface materials, by octave band, with the classroom limit.

Calculator Details

Reverberation time at 500 Hz (Sabine):0.67 sSee results ↓

Metres or feet for the room

Inside dimension of the room

Inside dimension of the room

Inside dimension of the room

Floor finish

Ceiling finish

Main wall finish

Glass in the walls (replaces that much wall)

Curtains, seating or panels in addition to the room surfaces

Octave band for the headline; 500 Hz is the usual single-number check

Your Results

Reverberation time at 500 Hz (Sabine): 0.67 s

Reverberation time at 500 Hz (Sabine)

0.67 s

Eyring RT60

0.59 s

Better for rooms with a lot of absorption

Room volume

189 m³

222 m² of surface

Total absorption

45.69 m² sabins

Average absorption coefficient 0.21

Classroom limit (ANSI S12.60)

0.6 s

Sabine result is above it at this band

At 500 Hz this 189 m³ room has a reverberation time of about 0.67 s (Sabine) or 0.59 s (Eyring).

Compare scenarios

Save these inputs as a scenario, change them, and compare the results side by side.

Loading, available in a moment

RT60 by octave band

RT60 by octave band

Detailed Breakdown

Reverberation time by octave band
BandAbsorption (m²)Sabine (s)Eyring (s)
125 Hz61.560.490.42
250 Hz56.390.540.47
500 Hz (shown)45.690.670.59
1,000 Hz50.310.60.53
2,000 Hz52.710.580.51
4,000 Hz41.880.730.66
Where the absorption comes from at 500 Hz
SurfaceMaterialArea (m²)αAbsorption (m²)
FloorVinyl tile on concrete630.031.89
CeilingAcoustic ceiling tile, suspended630.637.8
WallsGypsum board (drywall), 1/2 in on studs880.054.4
WindowsOrdinary window glass80.21.6

Coefficients are textbook values (Hall, Musical Acoustics, Table 15.1); real products vary, so use the manufacturer’s tested values for design.

How This Calculator Works

How It’s Calculated

Sabine: RT60 = 0.161 × V ÷ A, A = Σ (area × α)
Eyring: RT60 = 0.161 × V ÷ (−S × ln(1 − ᾱ)) · (V in m³, areas in m²; 0.049 with feet)

Your calculation: the room’s volume is 189 m³ and its surfaces absorb 45.69 m² sabins at 500 Hz (average α = 0.21), so Sabine gives 0.67 s and Eyring 0.59 s. Eyring treats each reflection as removing a fraction of the energy that is left, which matters when absorption is high, so it always gives the shorter time.

Frequently Asked Questions

What is RT60?

The reverberation time: how long it takes for sound in a room to fall by 60 decibels (to a millionth of its energy) after the source stops. Measurements usually extrapolate from a 20 or 30 dB decay (T20, T30), following ISO 3382.

How is reverberation time calculated?

With Sabine’s formula, RT60 = 0.161 × V ÷ A, where V is the room volume in m³ and A the total absorption: each surface’s area times its absorption coefficient, added up. The default 9 × 7 × 3 m room with a suspended acoustic ceiling has an RT60 of about 0.67 s at 500 Hz.

What is a good reverberation time for a classroom?

The American standard ANSI/ASA S12.60 sets a maximum of 0.6 s for unoccupied, furnished classrooms up to 283 m³ (10,000 ft³) and 0.7 s up to 566 m³ (20,000 ft³). Short reverberation keeps speech clear, which matters most for young children and students with hearing loss.

Sabine or Eyring: which should I use?

Sabine’s formula is the standard and works well for rooms with little absorption (average α below about 0.2). Eyring’s formula is more accurate for heavily treated rooms, where Sabine overestimates the time. With every surface fully absorbing, Eyring correctly gives zero while Sabine does not.

How much does carpet help?

It depends on the frequency. Carpet on felt underlay absorbs much more mid and high frequencies than vinyl. Swapping the default room’s vinyl floor for it cuts the 500 Hz RT60 from 0.67 to 0.44 s. Carpet does little at 125 Hz, where bass builds up; thin panels and membranes absorb low frequencies better.

Why is my empty room so echoey?

Hard surfaces reflect almost all sound. A 10 × 8 × 3 m room with bare concrete everywhere has an RT60 of about 7.2 s at 500 Hz, more than ten times a classroom’s. Furniture, people, curtains and ceiling tiles all add absorption.

Are the absorption coefficients accurate?

They are typical textbook values to one or two digits, from Hall’s Musical Acoustics. Real products vary with thickness, mounting and air gap, so for design use the manufacturer’s values measured to ASTM C423 or ISO 354, and confirm the result by measurement.

A diffuse-field estimate for a rectangular room using the Sabine and Eyring formulas (0.161 s/m), with octave-band absorption coefficients from Hall's Musical Acoustics (Table 15.1, as reproduced by HyperPhysics) and the ANSI/ASA S12.60 classroom limits as summarised by ASHA; both are pending review against the original documents. It leaves out air absorption (noticeable above 2 kHz in large rooms), people and furniture other than what you add, uneven absorption (flutter echoes), coupled spaces and non-rectangular shapes. For design or compliance, use tested product data and measure the room (ISO 3382-2).

Reverberation Time Calculator: RT60 by Sabine and Eyring

By FindMySum · Last reviewed

Clap in an empty gym and the sound hangs in the air; clap in a furnished living room and it stops almost at once. The difference is reverberation time, the most widely used single number in room acoustics. This calculator estimates it from the room's dimensions and surface materials using the formulas of Sabine and Eyring, across the six octave bands from 125 Hz to 4 kHz.

What RT60 measures

RT60 is the time it takes for sound energy in a room to fall by 60 decibels after the source stops, a millionth of its starting energy. Rooms for speech, such as classrooms and meeting rooms, need short times, under about a second. Rooms for music can be longer. Large hard rooms such as gyms, churches and stairwells often exceed several seconds.

Sabine's formula

Wallace Sabine found, in the 1890s, that reverberation time is proportional to a room's volume and inversely proportional to the absorption in it:

RT60 = 0.161 × V ÷ A

with V the volume in cubic metres and A the total absorption in square metres. Each surface contributes its area times its absorption coefficient α, which runs from 0 (perfect reflector) to 1 (perfect absorber, like an open window). In feet, the constant is 0.049.

Worked example: the default

The calculator opens with a 9 × 7 × 3 m classroom: vinyl floor, suspended acoustic ceiling, drywall walls and 8 m² of windows. At 500 Hz:

SurfaceAreaαAbsorption
Floor (vinyl)63 m²0.031.89
Ceiling (acoustic tile)63 m²0.637.8
Walls (drywall)88 m²0.054.4
Windows (glass)8 m²0.21.6
Total45.69 m²

RT60 = 0.161 × 189 ÷ 45.69 = 0.67 s. Almost all the absorption comes from the ceiling, which is why acoustic ceilings are standard in schools and offices.

Eyring's formula

Sabine's formula assumes absorption is small. In heavily treated rooms it overestimates the time; it even predicts some reverberation in a room with every surface perfectly absorbing. Eyring's refinement treats each reflection as removing a fraction of the energy left:

RT60 = 0.161 × V ÷ (−S × ln(1 − ᾱ))

where S is the total surface area and ᾱ = A ÷ S the average absorption coefficient. For the default room, ᾱ = 0.21 and Eyring gives 0.59 s. The two agree closely in live rooms and diverge as absorption rises. Both are shown so you can see the range.

Octave bands

Absorption depends on frequency, so reverberation does too. The chart and table show RT60 at 125, 250, 500, 1,000, 2,000 and 4,000 Hz. In the default room, the drywall and windows absorb bass well, so the 125 Hz time is shorter than at 500 Hz. Carpet does the opposite: it is almost useless at 125 Hz but absorbs strongly above 1 kHz.

Classrooms

The American National Standard for classroom acoustics, ANSI/ASA S12.60 Part 1, sets a maximum reverberation time of 0.6 s for unoccupied, furnished core learning spaces up to 283 m³ (10,000 ft³), and 0.7 s from 283 to 566 m³. The default room, at 0.67 s by Sabine at 500 Hz, would need a little more absorption, for example carpet or wall panels, to meet the limit.

Limits of the estimate

Both formulas assume a diffuse sound field: sound spread evenly in all directions with absorption well distributed. They are less reliable when:

  • absorption is concentrated on one surface (an absorbent ceiling over a hard floor can cause flutter echoes between the walls);
  • the room is very long, low or irregular;
  • air absorption matters, in large rooms at high frequencies.

The absorption coefficients are typical textbook values. Products differ, sometimes a lot, depending on thickness and mounting, so use manufacturers' tested values for real design, and measure the finished room.

For the floor area of an irregular room, the square footage calculator adds up shapes; the wavelength calculator converts frequency to wavelength, useful for sizing bass treatment.

More questions

Is reverberation the same as an echo?

No. An echo is a distinct repeat of a sound, heard when a reflection arrives more than about 50 milliseconds after the direct sound. Reverberation is the dense wash of many overlapping reflections that blend into a smooth decay. Large halls can have both.

Do concert halls want a long or short reverberation time?

Longer than speech rooms. Music, especially orchestral and choral music, benefits from a reverberation of roughly 1.5 to 2.5 seconds, which blends notes and adds warmth. Speech needs short reverberation so syllables don't smear into each other.

Why does reverberation change with frequency?

Materials absorb different frequencies differently. Porous materials such as carpet, curtains and ceiling tiles soak up mid and high frequencies but let bass through; thin panels and windows vibrate and absorb bass. Most rooms ring longer in the low octaves unless they are treated for it.

Do people in a room change the reverberation time?

Yes, noticeably. Clothed bodies are good absorbers, which is why a hall sounds livelier at rehearsal than at a full concert. The calculator includes occupied and unoccupied upholstered seating as added absorbers to show the difference.

What is a sabin?

The unit of sound absorption, named after Wallace Clement Sabine: one square foot (or one square metre, a metric sabin) of a perfectly absorbing surface, such as an open window. A surface's absorption in sabins is its area times its absorption coefficient.

Sources

This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.

Spotted a wrong result or a bug? Report a problem

May we count your visits with Invoker Analytics? It keeps a random visitor number in your browser. Your calculator inputs are never sent. Privacy policy