Skip to content

Thermal Expansion Calculator

How much a pipe, rail, deck board or tank grows and shrinks between Canadian winter and summer: linear, area and volume expansion for metals, PVC, PEX and liquids.

Calculator Details

Total movement, coldest to hottest:40.5 mm (1.59 in)See results ↓

Length of a pipe, rail or board; area of a sheet; or volume of a solid or liquid

Liquids only work with volume

Length when installed

Celsius or Fahrenheit for every temperature

Temperature when it is cut, fitted or filled

Much of Canada reaches −40 °C (−40 °F) in winter

Summer air in most of Canada tops out around 35 °C; dark surfaces in sun run hotter

Your Results

Total movement, coldest to hottest: 40.5 mm (1.59 in)

Total movement, coldest to hottest

40.5 mm (1.59 in)

Growth on the hottest day

0.0081 m

Size 10.0081 m at 35 °C

Shrinkage on the coldest day

0.0324 m

Size 9.9676 m at -40 °C

Linear coefficient α

54 ×10⁻⁶ per °C

Over a 75 °C swing

10 m of pvc pipe installed at 20 °C gains 0.0081 m of length on a 35 °C day and loses 0.0324 m at -40 °C: 0.0405 m of movement in all.

Compare scenarios

Save these inputs as a scenario, change them, and compare the results side by side.

Loading, available in a moment

Total movement by material

Total movement by material

Detailed Breakdown

Same size and temperatures, other materials
MaterialCoefficient (×10⁻⁶/°C)Growth (m)Shrinkage (m)Total (m)
Iron or steel120.00180.00720.009
Aluminium250.003750.0150.01875
Copper170.002550.01020.01275
Brass190.002850.01140.01425
Concrete or brick120.00180.00720.009
Glass (ordinary)90.001350.00540.00675
Glass (Pyrex)30.000450.00180.00225
Lead290.004350.01740.02175
Silver180.00270.01080.0135
Gold140.00210.00840.0105
Invar (nickel–iron)0.90.0001350.000540.000675
Marble2.50.0003750.00150.001875
PVC pipe (you)540.00810.03240.0405
PEX-a tubing1650.024750.0990.1238

Textbook averages near room temperature (OpenStax Table 1.2; Uni-Bell for PVC; Uponor for PEX). Products differ; follow the manufacturer’s gap and expansion-loop instructions.

How This Calculator Works

How It’s Calculated

ΔL = α × L₀ × ΔT · growth uses (hottest − installed), shrinkage (installed − coldest)

Your calculation: the coefficient is 54 × 10⁻⁶ per °C. Applied to 10 m, it grows by 0.0081 m from 20 °C to 35 °C and shrinks by 0.0324 m down to -40 °C. A joint, slip coupling or gap has to take up the total of 0.0405 m.

Frequently Asked Questions

What is the formula for thermal expansion?

Linear expansion is ΔL = α × L₀ × ΔT: the change in length equals the coefficient of expansion times the original length times the temperature change. Steel’s α is about 12 × 10⁻⁶ per °C, so a 1 m steel bar grows 0.012 mm for every 1 °C.

How much does PVC pipe expand in a Canadian year?

A lot more than metal. A 10 m PVC run installed at 20 °C grows 8.1 mm on a 35 °C day and shrinks 32.4 mm at −40 °C, 40.5 mm of movement in all, against 9 mm for steel over the same swing.

How much does PEX expand?

Uponor gives about 1.1 inches per 100 feet for every 10 °F, which this calculator reproduces (1.1 in). That is roughly 9.7 times copper, so long PEX runs need slack, loops or supports that let the tube move.

Why do railways and bridges have expansion gaps?

A 25 m steel rail laid at 20 °C moves about 22.5 mm between −40 °C and +35 °C. Blocked movement turns into large stresses, so bridges use expansion joints and older rail used gaps; modern continuous welded rail is laid stretched at a set temperature so it stays in tension most of the year.

How do liquids expand?

By volume, and usually much more than solids. Water’s volume coefficient is about 210 × 10⁻⁶ per °C near 20 °C, so 60 L warming from 15 °C to 35 °C gains about 0.252 L; gasoline expands over four times as much. That is why hot-water systems need expansion tanks.

What is the difference between α and β?

α is the linear coefficient (change in length per unit length per degree); β is the volume coefficient. For a solid that expands the same way in all directions, β ≈ 3α, and area expands at about 2α. Liquids have no fixed length, so only β applies.

Does it matter what temperature I install at?

Yes. Growth depends on how much hotter it gets than the install temperature, and shrinkage on how much colder. Vinyl and PVC fitted on a cold day need less room to shrink and more room to grow, which is why siding and deck manufacturers give gap tables by installation temperature.

Uses the first-order formulas ΔL = αL₀ΔT, ΔA = 2αA₀ΔT and ΔV = βV₀ΔT with average coefficients near room temperature (OpenStax University Physics Table 1.2, Uni-Bell for PVC pipe and Uponor for PEX-a). It assumes the part is free to move and the whole piece reaches the temperature you enter: surfaces in direct sun can run 20 °C or more above the air, and buried or insulated runs see much smaller swings. It leaves out thermal stress when movement is blocked, moisture swelling in wood, and the creep of plastics. Follow the manufacturer’s gap, fastener and expansion-loop rules and your building code.

Thermal Expansion Calculator: How Much Things Grow and Shrink

By FindMySum · Last reviewed

Almost everything gets bigger when it warms and smaller when it cools. Over a Canadian year that swing can be 75 °C or more, from −40 °C in January to +35 °C in July, enough to buckle siding, pull plumbing joints apart and crack slabs if nothing allows for it. This thermal expansion calculator shows how much a length, area or volume of a material moves between the coldest and hottest days, starting from the temperature it was installed at.

The formulas

For a length:

ΔL = α × L₀ × ΔT

where α is the material's linear coefficient of thermal expansion (per °C), L₀ the original length and ΔT the temperature change. For an area, ΔA = 2α × A₀ × ΔT, and for a volume, ΔV = β × V₀ × ΔT. For solids the volume coefficient β is about three times α; liquids have only a volume coefficient. These are the standard first-order forms, and the error from leaving out higher-order terms is far below a millionth of the size for weather swings.

Coefficients for common materials

Materialα (×10⁻⁶ per °C)
Invar0.9
Glass (ordinary)9
Steel, iron12
Concrete, brick12
Copper17
Brass19
Aluminium25
PVC pipe54
PEX-a tubing165

The metals and concrete come from the OpenStax University Physics table. PVC is the Uni-Bell figure of 0.00003 in/in/°F, and PEX is Uponor's 1.1 inches per 100 feet per 10 °F, both converted to °C. Plastics move four to fourteen times as much as steel.

Growth, shrinkage and total movement

A part only expands relative to the temperature it was fitted at. That is why the calculator asks for three temperatures:

  • Growth = α × L₀ × (hottest − installed)
  • Shrinkage = α × L₀ × (installed − coldest)
  • Total movement = growth + shrinkage = α × L₀ × (hottest − coldest)

A slip joint, expansion loop or gap has to absorb the total; the split between growth and shrinkage tells you which way it has to move from where you set it.

Worked example: the default PVC run

A 10 m run of PVC pipe installed at 20 °C, in a space that can reach −40 °C and +35 °C:

  • Growth to 35 °C: 0.000054 × 10,000 mm × 15 = 8.1 mm
  • Shrinkage to −40 °C: 0.000054 × 10,000 mm × 60 = 32.4 mm
  • Total: 40.5 mm, about 1.6 inches

The same run in steel would move only 9 mm. Fitted on a warm day, most of the PVC's movement is shrinkage, so couplings must not pull apart in winter.

Worked example: a bridge

OpenStax's classic example is the Golden Gate Bridge, whose steel main span is 1,275 m. Between −15 °C and 40 °C it changes length by 12 × 10⁻⁶ × 1,275 × 55 ≈ 0.84 m, which is why big bridges have toothed expansion joints you can feel as you drive over them.

Worked example: liquids

A 60 L fuel tank filled with gasoline at 15 °C and parked in the sun until it reaches 35 °C: the gasoline expands by 950 × 10⁻⁶ × 60 × 20 = 1.14 L. The steel tank grows too, but only by about 0.04 L, so about 1.1 L would spill, which is why you shouldn't fill a tank to the brim on a hot day.

Canadian practice

  • Plumbing: PEX and PVC runs need slack, offsets or expansion loops on long straight lengths, especially hot-water lines and anything in an unheated space.
  • Siding and trim: vinyl and aluminium siding are hung loosely on slotted holes so panels can slide. Installers leave larger gaps when it's cold during installation.
  • Decks and railings: aluminium railings, composite decking and long fascia boards all need end gaps. Real deck surfaces in full sun can run 20 °C or more above the air temperature, so use the surface temperature for the hottest value.
  • Concrete: driveways and sidewalks use control joints every few metres and expansion joints against foundations.

Manufacturers publish gap and loop tables for their own products, and those take priority over a general estimate.

Limits

The coefficients are averages near room temperature; they change slightly over a wide swing, and real products vary with formulation. The calculation assumes the material can move freely and reaches the temperatures you enter all the way through. When movement is blocked, expansion becomes stress instead, which this calculator does not compute. Wood also swells and shrinks with moisture, usually much more than with temperature.

For the weight of a metal bar or plate, try the metal weight calculator; for deck finishing, the deck stain calculator; and for fence materials, the fence calculator.

More questions

Why does a jar lid loosen under hot water?

The metal lid has a larger expansion coefficient than the glass jar, about 12 to 25 millionths per degree against 9 for ordinary glass, so hot water makes the lid grow slightly more than the rim it grips. A tiny change in diameter is enough to break the seal's friction.

Does water always expand when it warms?

No. Between 0 °C and about 4 °C water contracts as it warms, which is why the densest water, at 4 °C, sinks to the bottom of lakes in winter. Above 4 °C it expands normally, and when it freezes it expands by about 9%, which is what bursts pipes.

What is Invar used for?

Invar is a nickel–iron alloy with an expansion coefficient around 1 millionth per degree, over ten times smaller than ordinary steel. It is used in precision clocks, measuring tapes for surveying, and instrument parts that must keep their dimensions as the temperature changes.

Why does concrete need control joints?

Concrete shrinks as it cures and then expands and contracts with temperature at roughly the same rate as steel. A long slab can't move freely, so it cracks. Control joints are planned weak lines that make the cracks happen in straight, tidy places, and expansion joints let slabs move against walls and other slabs.

Why don't the steel bars inside reinforced concrete crack it as it heats up?

Because steel and concrete expand at almost the same rate, about 12 millionths per degree. That lucky match is a big reason reinforced concrete works: the two materials move together instead of pulling apart as temperatures swing.

Sources

This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.

Spotted a wrong result or a bug? Report a problem

May we count your visits with Invoker Analytics? It keeps a random visitor number in your browser. Your calculator inputs are never sent. Privacy policy