Wheatstone Bridge Calculator

Find the unknown resistor of a balanced Wheatstone bridge, the output voltage of an unbalanced one, and quarter, half and full strain-gauge bridge output in mV/V.

Calculator Details

Unknown resistance (Rx):600 ΩSee results ↓

The unknown resistor of a balanced bridge, the output of an unbalanced bridge, or a strain-gauge bridge

All four arms use this unit

Ratio arm

Ratio arm

Variable or known arm; in balance mode the value that zeroes the meter

Voltage across the bridge

Your Results

Unknown resistance (Rx): 600 Ω

Unknown resistance (Rx)

600 Ω

The bridge reads zero at balance

Midpoint voltages

6.6667 V · 6.6667 V

Left (R1/R2) · right (R3/Rx)

Output resistance

266.67 Ω

Seen by the meter (Thevenin)

The bridge balances when Rx = 600, giving zero output.

Compare scenarios

Save these inputs as a scenario, change them, and compare the results side by side.

Loading, available in a moment

Detailed Breakdown

V+ supply− supplyR1 100 ΩR2 200 ΩR3 300 ΩRx 600 Ω
Meter between the midpoints reads 0 mV
The four arms
ArmResistanceRole
R1100 Ωratio arm
R2200 Ωratio arm
R3300 Ωknown arm
Rx600 Ωunknown

How This Calculator Works

How It’s Calculated

V_out = V × (Rx ÷ (R3 + Rx) − R2 ÷ (R1 + R2)) · balance: Rx = R2 × R3 ÷ R1
Strain gauge: R = R_g × (1 ± GF × ε); quarter bridge ≈ V × GF × ε ÷ 4

Your calculation: Rx = 200 × 300 ÷ 100 = 600 Ω.

Frequently Asked Questions

What is a Wheatstone bridge?

Four resistors in a diamond: two voltage dividers side by side across the same supply, with a meter between their midpoints. When the two dividers have the same ratio the meter reads zero, the bridge is balanced, and an unknown resistor can be found from the other three without trusting the meter’s accuracy.

How do I find the unknown resistor?

At balance R1/R2 = R3/Rx, so Rx = R2 × R3 ÷ R1. With R1 = 100 Ω, R2 = 200 Ω and R3 = 300 Ω, Rx = 600 Ω. In a lab bridge R3 is a precision variable resistor turned until the galvanometer reads zero.

What is the output of an unbalanced bridge?

The difference between the two midpoint voltages: V_out = V × (Rx ÷ (R3 + Rx) − R2 ÷ (R1 + R2)). With 10 V across three 1 kΩ arms and Rx = 1.1 kΩ, the output is 238.1 mV. The output is not quite proportional to the change in Rx, which matters for large changes.

What output does a strain gauge bridge give?

A metal-foil gauge with a gauge factor of 2 at 1000 µε (0.1% stretch) changes resistance by 0.2%. A quarter bridge then gives about 0.4995 mV per volt of excitation, a half bridge in bending 1 mV/V and a full bridge in bending 2 mV/V. Those are tiny signals, which is why strain amplifiers have high gain.

Why use a half or full bridge instead of a quarter bridge?

More active gauges give more output and cancel unwanted effects. Gauges in adjacent arms cancel temperature changes that affect them equally, and opposite bending gauges double the signal. A full bending bridge is perfectly linear and four times as sensitive as a quarter bridge.

What is the gauge factor?

The ratio of the fractional change in resistance to the strain: GF = (ΔR/R) ÷ ε. Metal-foil gauges are about 2; semiconductor gauges can exceed 100 but are more nonlinear and temperature sensitive. The exact value is printed on the gauge packet.

Why is a quarter bridge slightly nonlinear?

Because the gauge also changes the total resistance of its arm, which changes the current through it. At 1000 µε the error is about 0.1%, negligible for most work; at large strains (above about 10,000 µε) it grows and should be corrected.

Treats the bridge as two ideal voltage dividers measured by a meter that draws no current (OpenStax College Physics 2e §21.5). Strain-gauge outputs are computed exactly from the four arm resistances, with the linear estimates from National Instruments’ strain-gauge guide for comparison. It leaves out lead-wire resistance and its compensation, meter loading, temperature effects on the gauges, shunt calibration, transverse sensitivity and amplifier gain and offset, and it does not convert strain to stress.

Wheatstone Bridge Calculator: Balance, Output and Strain Gauges

By FindMySum · Last reviewed

The Wheatstone bridge is one of the oldest and most useful circuits in measurement: four resistors arranged as two voltage dividers, with a meter between their midpoints. When the dividers have the same ratio, the meter reads exactly zero. This Wheatstone bridge calculator finds the unknown resistor of a balanced bridge, the output voltage of an unbalanced one, and the output of strain-gauge bridges in the quarter, half and full configurations.

The circuit

The calculator uses this layout:

  • the left arm: R1 on top, R2 below,
  • the right arm: R3 on top, Rx below,
  • a supply voltage V across the top and bottom, and a meter between the two midpoints.

Each arm is a voltage divider. The left midpoint sits at V × R2 ÷ (R1 + R2) and the right at V × Rx ÷ (R3 + Rx). The meter reads the difference:

V_out = V × (Rx ÷ (R3 + Rx) − R2 ÷ (R1 + R2))

Balance and the unknown resistor

The output is zero when both dividers have the same ratio, R1/R2 = R3/Rx, so:

Rx = R2 × R3 ÷ R1

Worked example (the default): with R1 = 100 Ω, R2 = 200 Ω and R3 = 300 Ω, the bridge balances at Rx = 200 × 300 ÷ 100 = 600 Ω. In a laboratory bridge, R3 is a precision decade resistor adjusted until a sensitive galvanometer reads zero. At that point the result depends only on the three known resistors; the meter only has to detect zero, which is why bridges are so accurate.

The unbalanced bridge

In sensor circuits, the bridge starts balanced and one or more arms change with the quantity being measured. The output then measures the imbalance. With 10 V across arms of 1 kΩ and Rx raised to 1.1 kΩ:

  • left midpoint: 10 × 1000 ÷ 2000 = 5.000 V
  • right midpoint: 10 × 1100 ÷ 2100 = 5.238 V
  • output: 0.238 V, or 23.8 mV per volt of excitation

The calculator also gives the output resistance the meter sees, R1‖R2 + R3‖Rx, which tells you how much a meter or amplifier with finite input resistance will load the bridge.

Strain-gauge bridges

A strain gauge is a thin metal foil grid whose resistance rises when stretched: ΔR/R = GF × ε, where ε is the strain and GF the gauge factor, about 2 for metal foil. At 1000 microstrain (a 0.1% stretch), a 350 Ω gauge changes by only 0.7 Ω, far too little to read directly, but easy to see in a bridge.

ConfigurationActive gaugesOutput at 1000 µε, GF 2
Quarter bridge10.4995 mV/V (≈ GF·ε/4)
Half bridge, bending2 (+ε, −ε)1.000 mV/V (GF·ε/2)
Half bridge, axial with Poisson gauge2 (+ε, −νε)0.650 mV/V (≈ GF·ε(1 + ν)/4)
Full bridge, bending42.000 mV/V (GF·ε)
Full bridge, axial with Poisson gauges41.299 mV/V (≈ GF·ε(1 + ν)/2)

The calculator works the output out exactly from the four arm resistances and also shows the usual linear estimate, so you can see the nonlinearity: about −0.1% for a quarter bridge at 1000 µε, and zero for the bending bridges, whose changes balance exactly. Multiply mV/V by the excitation voltage for the actual signal: at 10 V, a quarter bridge at 1000 µε gives about 5 mV.

Choosing a configuration

More active gauges give more signal and better rejection of temperature changes, because gauges in adjacent arms that warm up equally cancel out. A quarter bridge is the simplest and needs only one gauge, but it is the least sensitive and the most affected by temperature and lead wires. Load cells and transducers almost always use full bridges.

Limits

The calculation assumes an ideal meter that draws no current and ignores the resistance of the lead wires to the gauges. Real installations also need temperature compensation, shunt calibration and amplifier gain and offset. Strain is reported as measured; converting it to stress needs the material's modulus.

More questions

Who invented the Wheatstone bridge?

Samuel Hunter Christie described the circuit in 1833, and Charles Wheatstone popularised it in 1843 as a way to measure resistance precisely, so it carries his name. Before digital meters, bridges were the standard laboratory method for accurate resistance measurement, because a null reading depends only on the known resistors, not on the meter's calibration.

Where are Wheatstone bridges used today?

Inside load cells in bathroom and truck scales, pressure transducers, torque sensors and accelerometers, all of which use strain gauges in a bridge. Resistive temperature sensors (RTDs and thermistors), gas sensors and hot-wire anemometers also sit in bridges, because the circuit turns a small resistance change into a voltage near zero that is easy to amplify.

What is a load cell?

A precisely machined metal element with strain gauges bonded to it, usually wired as a full bridge. Weight bends or compresses the element, the gauges change resistance, and the bridge output in mV/V is proportional to the load. Load cells are rated by their full-scale output, typically 1 to 3 mV/V.

Why does lead-wire resistance matter in a quarter bridge?

The wires from the bridge to a remote gauge add resistance to the gauge's arm, which shifts the zero and reduces sensitivity, and their resistance changes with temperature. A three-wire connection puts one lead in each of two adjacent arms so the effects cancel; a full bridge with remote sensing removes the problem almost completely.

How do I convert strain to stress?

For a simple uniaxial stress in an elastic material, stress = Young's modulus × strain. Steel has E of about 200 GPa, so 1000 µε corresponds to about 200 MPa. For combined loading you need strain in more than one direction, measured with a rosette of gauges, and the material's Poisson's ratio.

Sources

This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.

Spotted a wrong result or a bug? Report a problem