Skip to content

BTU & Air Conditioner Size Calculator

Find the air conditioner size your room needs in BTU per hour, tons and watts, using the ENERGY STAR sizing chart with sun, occupancy and kitchen adjustments.

Calculator Details

Air conditioner size:9,000 BTU/hSee results ↓

Floor area of the space to cool (length × width)

Square feet or square metres

Heavily shaded rooms need about 10% less; very sunny rooms about 10% more

Adds 600 BTU/h for each person beyond 2

Cooking heat adds 4,000 BTU/h

Your Results

Air conditioner size: 9,000 BTU/h

Air conditioner size

9,000 BTU/h

0.75 tons · 2,638 W of cooling

How the size adds up

Chart size

9,000 BTU/h

350–400 sq ft band

Sun exposure

+0 BTU/h

Normal

Extra people

+0 BTU/h

0 beyond 2

Kitchen

+0 BTU/h

Total

9,000 BTU/h

A 400 sq ft (37.2 m²) room needs an air conditioner of about 9,000 BTU/h (0.75 tons, 2,638 W of cooling).

Compare scenarios

Save these inputs as a scenario, change them, and compare the results side by side.

Loading, available in a moment

Detailed Breakdown

ENERGY STAR room air conditioner sizing chart
Area (sq ft)Capacity (BTU/h)Your room
100–1505,000
150–2506,000
250–3007,000
300–3508,000
350–4009,000(you) 400 sq ft
400–45010,000
450–55012,000
550–70014,000
700–1,00018,000
1,000–1,20021,000
1,200–1,40023,000
1,400–1,50024,000
1,500–2,00030,000
2,000–2,50034,000

Before the sun, people and kitchen adjustments.

How This Calculator Works

How the Size Is Calculated

BTU/h = chart size × (1 ± 10% for sun or shade) + 600 × people beyond 2 + 4,000 for a kitchen
Tons = BTU/h ÷ 12,000 · Watts = BTU/h × 0.29307

Your calculation: 400 sq ft (37.2 m²) falls in the 350–400 sq ft band: 9,000 BTU/h. +0 for sun, +0 for people, +0 for a kitchen = 9,000 BTU/h, or 0.75 tons.

Frequently Asked Questions

How many BTU do I need per square foot?

The ENERGY STAR chart works out to roughly 20–35 BTU/h per square foot, more per square foot for small rooms than large ones. A 400 sq ft room needs about 9,000 BTU/h; a 1,000 sq ft space about 18,000. The chart assumes an 8-foot ceiling.

Which size do I get if my room is exactly on a boundary in the chart?

Neighbouring rows of the ENERGY STAR chart share their end values (100–150 sq ft, then 150–250), so the calculator reads each row as “up to and including” its upper figure. A room of exactly 150 sq ft therefore gets the 5,000 BTU/h row, and anything larger, even 150.5 sq ft, moves up to 6,000 BTU/h. If your room is right at a boundary and also sunny or busy, the adjustments will usually decide which unit to buy.

What does BTU mean on an air conditioner?

It is the cooling capacity: how much heat the unit can remove from the room per hour, in British thermal units. One BTU is about 1,055 joules, so 1 BTU/h is about 0.293 W, and a 10,000 BTU/h unit removes about 2.9 kW of heat. It is not the electricity the unit uses, which is several times less.

What is a ton of air conditioning?

A ton is 12,000 BTU/h, the cooling from melting a ton of ice in a day. Central systems are sold in tons (1.5, 2, 3 tons…); room units are sold in BTU/h.

Is a bigger air conditioner better?

No. An oversized unit cools the room quickly and shuts off before it has removed much moisture, leaving the room cold and clammy, and its frequent on–off cycling wastes energy and wears it out. An undersized one runs constantly on hot days. Pick the size closest to the result.

How do sun, people and kitchens change the size?

ENERGY STAR suggests reducing capacity by 10% for a heavily shaded room, increasing it by 10% for a very sunny one, adding 600 BTU/h for each regular occupant beyond 2, and adding 4,000 BTU/h if the unit cools a kitchen.

What about high ceilings?

The chart assumes 8-foot ceilings. Rooms with higher ceilings have more air and wall area to cool, so many people size up one step; ENERGY STAR doesn’t give a figure, and the calculator doesn’t adjust for it.

Can I use this for central air or a heat pump?

Only as a rough first guide. Whole-house systems should be sized with a heat-loss and heat-gain calculation (ACCA Manual J in the US, CSA F280 in Canada) that accounts for insulation, windows, air leakage and climate. Contractors and many rebate programs require one.

A rule of thumb for sizing a room air conditioner, not a heat-gain calculation (ACCA Manual J, CSA F280). Not included: ceiling height above 8 ft, insulation, window area and orientation, climate, and heating. ENERGY STAR doesn’t say in what order to apply its adjustments; the percentage is applied to the chart size before the fixed additions.

Source: ENERGY STAR, Room Air Conditioners: sizing chart (area to be cooled → capacity needed, BTU per hour, assuming an 8-foot ceiling) and 'Adjust as necessary': heavily shaded room −10%, very sunny room +10%, +600 BTU/h for each person beyond two regular occupants, +4,000 BTU/h if the unit is used in a kitchen. Retrieved 2026-11-08.

BTU Calculator: What Size Air Conditioner Does Your Room Need?

By FindMySum · Last reviewed

A BTU calculator tells you how much cooling capacity a room air conditioner needs, measured in British thermal units per hour. Getting the size right matters more than most buyers expect: too small and the unit runs flat out without keeping up on hot afternoons, too big and it cools the air so quickly that it never runs long enough to remove humidity. This article explains the ENERGY STAR sizing chart the calculator uses, the adjustments for sun, people and kitchens, how BTU relate to tons and watts, and a worked example with the calculator's defaults.

What a BTU is

A British thermal unit is the heat needed to raise one pound of water by one degree Fahrenheit, about 1,055 joules. Air conditioners are rated by how many BTU of heat they can remove from a room each hour, written BTU/h or often just "BTU". Because one watt is one joule per second, 1 BTU/h equals about 0.293 W, so a 10,000 BTU/h unit removes about 2,930 W of heat.

That figure is cooling output, not electricity input. An air conditioner moves heat rather than creating cold, so it removes several times more heat than the electricity it uses. Its efficiency ratio tells you how many: a unit with an energy efficiency ratio of 10 removes 10 BTU/h for every watt it draws.

Larger systems are rated in tons: one ton is 12,000 BTU/h, the rate of cooling from melting a short ton of ice over a day. A "2-ton" central air system delivers 24,000 BTU/h.

The ENERGY STAR sizing chart

ENERGY STAR publishes a simple chart that matches floor area to room air conditioner capacity, assuming an 8-foot ceiling:

Area to cool (sq ft)Capacity (BTU/h)
100 to 1505,000
150 to 2506,000
250 to 3007,000
300 to 3508,000
350 to 4009,000
400 to 45010,000
450 to 55012,000
550 to 70014,000
700 to 1,00018,000
1,000 to 1,20021,000
1,200 to 1,40023,000
1,400 to 1,50024,000
1,500 to 2,00030,000
2,000 to 2,50034,000

Neighbouring rows share their boundary values, so the calculator reads each row as "up to and including" its upper figure and puts a room that is exactly on a boundary in the lower row: 150 sq ft gets 5,000 BTU/h, while anything over 150 sq ft gets 6,000. Areas entered in square metres are converted at 0.09290304 m² per square foot.

The adjustments

ENERGY STAR then suggests adjusting the chart figure:

  • Heavily shaded room: reduce capacity by 10%.
  • Very sunny room: increase capacity by 10%.
  • More than two people regularly in the room: add 600 BTU/h for each extra person.
  • Kitchen: add 4,000 BTU/h for the heat from cooking.

The guidance doesn't say in what order to apply these. The calculator applies the sun or shade percentage to the chart figure first and then adds the fixed amounts for people and the kitchen, so the percentage doesn't inflate the fixed additions.

Worked example: the calculator's defaults

The calculator opens with a 400 sq ft room with normal sun, used by two people, and not a kitchen.

  1. 400 sq ft falls in the 350 to 400 sq ft row: 9,000 BTU/h.
  2. No sun or shade adjustment, no extra people, no kitchen.
  3. In tons: 9,000 ÷ 12,000 = 0.75 ton.
  4. In watts of cooling: 9,000 × 0.29307 ≈ 2,638 W.

Make the same room very sunny and add two more regular occupants: 9,000 + 900 (10%) + 1,200 (two extra people) = 11,100 BTU/h, so you would look at a 12,000 BTU/h unit, the next common size up. Room units come in steps such as 5,000, 6,000, 8,000, 10,000, 12,000 and 14,000 BTU/h; choose the size nearest the result rather than jumping well above it.

Why oversizing backfires

An air conditioner dehumidifies as a side effect of cooling: moisture condenses on the cold coil while the compressor runs. An oversized unit reaches the thermostat setting within minutes and switches off, so little moisture is removed and the room feels cold but damp. The frequent starts also waste energy and shorten the compressor's life. A correctly sized unit runs longer, steadier cycles, which is better for comfort and efficiency.

Where a chart isn't enough

The chart is meant for single rooms with ordinary construction and 8-foot ceilings. It doesn't know about insulation levels, window size and direction, air leakage, ceiling height or your climate. For central air conditioning or a heat pump serving a whole house, contractors use a room-by-room heat-gain calculation, ACCA Manual J in the United States or CSA F280 in Canada, and many rebate programs require one. If your space is larger than the chart's 2,500 sq ft, open to other floors, or under a hot roof, treat this calculator's figure as a starting point for that conversation rather than an answer.

More questions

Should I choose a window, portable or ductless mini-split unit?

Window units are usually the most efficient and cheapest per BTU of the three plug-in options. Portable units are easier to install but less efficient, especially single-hose models that pull warm outside air into the room. Ductless mini-splits cost more to install but are quieter, far more efficient and can also heat as a heat pump, which suits rooms used year-round.

How do I compare the efficiency of two air conditioners of the same size?

Look at the combined energy efficiency ratio (CEER) for room units, or SEER2 for central and mini-split systems. A higher number means more cooling per unit of electricity. ENERGY STAR certified room air conditioners must beat the federal minimum efficiency standard, and the label shows estimated yearly energy cost.

Can one air conditioner cool several rooms?

Only if the air can move freely between them. A room unit cools the space it blows into; closed doors and long hallways leave other rooms warm. Size for the combined area of rooms that are open to each other, and use fans to move air, or consider a multi-zone mini-split for separate rooms.

How much electricity does a 10,000 BTU air conditioner use?

Divide the BTU rating by the efficiency ratio to get watts: a 10,000 BTU/h unit with a CEER of 10 draws about 1,000 W while the compressor runs. Running 8 hours a day for 90 days, that is about 720 kWh a season. Use the FindMySum electricity cost calculator with your local rate to turn that into dollars.

Does insulation change the size I need?

Yes. The ENERGY STAR chart assumes typical construction. A well-insulated, airtight room with good windows needs less cooling than the chart suggests, and an attic room under a hot roof or a room with large west-facing windows needs more. That is why whole-house systems should be sized with a proper heat-gain calculation rather than a chart.

Sources

This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.

Spotted a wrong result or a bug? Report a problem