A tank volume calculator does two jobs. It tells you how much a tank holds when full, and, from the depth of liquid inside, how much it holds right now. The second is the one people need most, for heating oil, diesel, rainwater, septic and process tanks, and it is where intuition fails: in a tank lying on its side, half the height is half the volume, but a quarter of the height is well under a quarter. This article explains the geometry for each shape, why horizontal tanks behave the way they do, and how to read the dip chart.
Full capacity
For tanks with straight vertical sides, capacity is the floor area times the height.
- Rectangular: length × width × height.
- Vertical cylinder: π × radius² × height.
- Cone bottom: a cylinder standing on a cone; the cone holds a third of a cylinder of the same height, π × r² × cone height ÷ 3.
Tanks lying on their side use the area of the end instead: a horizontal cylinder holds π × r² × length, a horizontal oval (an elliptical end, W wide and H tall) holds π × (W ÷ 2) × (H ÷ 2) × length, and a capsule adds a hemisphere at each end, together a sphere of 4/3 × π × r³. A vertical capsule has the same parts stood on end.
Volumes come out in cubic metres or cubic inches depending on your unit. One cubic metre is 1,000 litres; one US gallon is exactly 231 cubic inches or 3.785411784 litres; and one imperial gallon is 4.54609 litres.
Partly filled tanks
In a vertical tank with straight sides, the liquid volume is proportional to the depth. In a horizontal round tank it isn't, because the width of the liquid surface changes with the depth. The liquid's end area is a circular segment:
segment = r² × arccos((r − h) ÷ r) − (r − h) × √(2rh − h²),
where r is the radius and h the liquid height. Multiply by the length for a horizontal cylinder. The capsule's ends add a spherical cap, π × h² × (3r − h) ÷ 3, and an oval tank uses the circular formula stretched by the ratio of its width to its height. In a cone-bottom tank, the cone fills slowly at first because its radius grows with the depth.
The dip chart
The calculator builds a dip chart for your tank: the volume at every tenth of its height. Print it and keep it by the tank, and a dipstick reading becomes litres or gallons at a glance. Heating oil suppliers and tank makers publish charts like this for their own tanks, and those are the right reference for the flat-sided obround tanks common in basements, whose shape is not one of the standard solids here.
Worked example: the calculator's defaults
The calculator opens with a vertical cylinder 100 cm across and 150 cm tall, with 100 cm of liquid.
- Capacity: π × 0.5² × 1.5 = 1.1781 m³ = 1,178.1 litres (311.2 US gallons, 259.1 imperial gallons).
- Liquid: π × 0.5² × 1.0 = 0.7854 m³ = 785.4 litres.
- Percent full: 785.4 ÷ 1,178.1 = 66.7%, the same as the height fraction, because the sides are vertical.
Switch the shape to a horizontal cylinder 1 m across and 2 m long with 25 cm of liquid, and the tank holds 307.1 of its 1,570.8 litres: 19.6%, although the liquid reaches a quarter of the height.
Getting good measurements
Measure inside dimensions where you can, and for horizontal tanks measure the liquid height at the middle of the tank, since a slight tilt shifts the level at the ends. A flat dipstick read at eye level is more reliable than a round one. When the stakes are high, such as a fuel order or a chemical dose, compare the calculation with the maker's chart or a metered fill.
More questions
Should I measure the inside or the outside of the tank?
The inside. Steel tank walls are only a few millimetres thick, so outside measurements are close for large steel tanks, but plastic and concrete tanks have thick walls that can take several percent off the capacity. If you can only measure the outside, subtract twice the wall thickness from each dimension.
How do I find the liquid height in a tank I can't see into?
Use a dipstick through the fill opening, a sight gauge if the tank has one, or a float gauge. For water tanks, tapping down the side can find the level by sound. Ultrasonic level sensors give a continuous reading and are common on rainwater and fuel tanks.
What size heating oil tank do I need?
It depends on how much oil the house burns and how often you want deliveries. A typical older home in Canada might use 2,000 to 4,000 litres a year, so a tank of about 900 to 1,100 litres needs filling several times a winter. Your supplier's delivery records are the best guide.
How do I calculate a rainwater tank's capacity in a storm?
Each millimetre of rain on one square metre of roof is one litre. Multiply the roof area in square metres by the rainfall in millimetres, then allow for losses of 10 to 20% to first-flush diverters, gutters and evaporation, and compare the result with the tank capacity here.
Does temperature change how much a tank holds?
The tank's capacity barely changes, but the liquid does: heating oil and gasoline expand about 1% for every 10 to 12 °C of warming. That is why fuel suppliers leave room at the top and why fuel is sometimes sold at a volume corrected to 15 °C.