Activation Energy Calculator: Arrhenius Equation, Plot and Q10
By FindMySum · Last reviewed
Reactions speed up when it gets warmer, often dramatically: milk sours in hours on a counter and keeps for days in a fridge. The Arrhenius equation explains how, through a single number, the activation energy. This activation energy calculator finds Ea from rate constants measured at two temperatures or from a fitted Arrhenius plot, predicts the rate constant at a new temperature, and converts to and from the Q₁₀ coefficient that biologists use.
The Arrhenius equation
k = A × e^(−Ea / RT)
k is the rate constant, A the pre-exponential (frequency) factor, Ea the activation energy, R = 8.314 462 618 J/(mol·K) the gas constant and T the absolute temperature. The exponential term is the fraction of collisions energetic enough to react.
Writing it for two temperatures and dividing eliminates A:
ln(k₂/k₁) = −(Ea/R) × (1/T₂ − 1/T₁)
so Ea = R × ln(k₂/k₁) ÷ (1/T₁ − 1/T₂). Temperatures must be in kelvin; the calculator converts °C and °F.
Worked example: N₂O₅ decomposition
The calculator opens with OpenStax's exercise on the decomposition of dinitrogen pentoxide: k = 1.66 L/(mol·s) at 650 K and 7.39 L/(mol·s) at 700 K.
- ln(7.39 ÷ 1.66) = 1.493
- 1/650 − 1/700 = 1.099 × 10⁻⁴ K⁻¹
- Ea = 8.314 × 1.493 ÷ 1.099 × 10⁻⁴ = 113,000 J/mol = 113 kJ/mol
OpenStax rounds the answer to 1.1 × 10⁵ J/mol. The calculator also returns the pre-exponential factor, A ≈ 2.0 × 10⁹ L/(mol·s), and the Q₁₀ over the 50 K interval, 1.35.
The Arrhenius plot
With several measurements, a graph of ln k against 1/T is a straight line with slope −Ea/R and intercept ln A. Choose "several measurements" and enter one temperature and rate constant per line. The calculator fits the line by least squares, which uses every point rather than just two.
For OpenStax's data on 2HI → H₂ + I₂ (five points from 555 to 781 K), the fitted slope is −22,290 K, giving Ea = 185 kJ/mol with R² = 0.9996. OpenStax's estimate from the first and last points is about 180 kJ/mol. A low R² warns that a measurement is off or that the mechanism changes across the temperature range.
Predicting the rate at another temperature
If you know Ea and one rate constant, the same equation predicts k at any other temperature:
k₂ = k₁ × e^(−(Ea/R)(1/T₂ − 1/T₁))
With Ea = 50 kJ/mol, warming from 25 °C to 35 °C multiplies the rate by 1.92, almost exactly the familiar "doubles every 10 °C". Cooling from 20 °C to a fridge's 4 °C cuts it to 31%, which is why refrigeration roughly triples the life of perishable food.
Q₁₀, the biologist's version
Q₁₀ is the factor by which a rate increases for a 10 °C rise:
Q₁₀ = (k₂/k₁)^(10 / (T₂ − T₁))
Physiology and ecology often quote Q₁₀ values of 2 to 3 for metabolism and enzyme activity. Choose "Rate change from a Q₁₀" to apply one: with Q₁₀ = 2, going from 20 °C to body temperature, 37 °C, multiplies the rate by 2^1.7 = 3.25. The calculator also shows the activation energy that corresponds to that change, 52 kJ/mol here. For a fixed Ea, Q₁₀ is not quite constant: it falls slowly as the temperature rises.
Limits
The Arrhenius equation treats Ea and A as constant over the temperature range, which holds well for most simple reactions over modest ranges. It fails when the mechanism changes, when enzymes denature at high temperature, or for reactions that tunnel at very low temperatures. For precise work, more measurements over a wider range give a more reliable Ea.
More questions
Who was Arrhenius?
Svante Arrhenius, a Swedish chemist, proposed the equation in 1889 to explain why reaction rates rise so steeply with temperature. He also developed the theory of ions in solution, for which he won the 1903 Nobel Prize in Chemistry, and was among the first to estimate how much carbon dioxide warms the Earth.
Why do reaction rates rise so quickly with temperature?
Molecular energies follow a distribution, and only the high-energy tail clears the activation barrier. Warming shifts the whole distribution, and the tail grows much faster than the average: a 10 °C rise near room temperature raises the average kinetic energy by about 3%, but can double the number of molecules above a 50 kJ/mol barrier.
What units should the rate constant have?
Any, as long as all the rate constants use the same ones. The units depend on the reaction order: s⁻¹ for first order, L/(mol·s) for second order. Only ratios of k enter the activation energy, so the units cancel; the pre-exponential factor A comes out in the same units as k.
How is activation energy used in shelf-life testing?
Accelerated ageing stores products at raised temperatures, measures how fast they degrade, and uses the Arrhenius equation to predict the shelf life at storage temperature. Drug stability guidelines and food scientists use this approach, often with a Q₁₀ of 2 to 3, but it only works if the same degradation reaction dominates at both temperatures.
What is a typical activation energy?
Most chemical reactions that run at a useful rate near room temperature have activation energies of roughly 40 to 120 kJ/mol. Diffusion-limited reactions can be below 20 kJ/mol, while reactions that need heating, such as many thermal decompositions, run from 150 to over 250 kJ/mol.
Sources
This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.