Skip to content

PPM Calculator

Convert ppm, ppb and % to mg/L, µg/L and mg/m³ for water and air, turn EC readings into ppm, and compare with Canadian drinking-water and CO₂ guidelines.

Calculator Details

Parts per million (by mass):30 ppmSee results ↓

A solution in water (by mass), a gas in air (by volume), or a conductivity meter reading

The value from your test or lab report

Health Canada drinking-water limits, or the indoor CO₂ guideline

For molar mass, mol/L and gas mg/m³; leave blank to use the guideline substance

Your Results

Parts per million (by mass): 30 ppm

Parts per million (by mass)

30 ppm

mg/L

30

30,000 µg/L

ppb

30,000

Percent by mass

0.003%

Molarity

0.00048384 mol/L

NO3: 62.004 g/mol

Below the guideline

66.67% of the limit

Nitrate (as nitrate, NO₃⁻): 45 mg/L (MAC)

30 mg/L is 30 ppm by mass (30,000 ppb). That is 66.667% of the MAC for nitrate (as nitrate, no₃⁻) (45 mg/L), so it is below the guideline.

Compare scenarios

Save these inputs as a scenario, change them, and compare the results side by side.

Loading, available in a moment

Your sample against the MAC

Your sample against the MAC

Detailed Breakdown

Your concentration in every unit
UnitValue
mg/L30
µg/L30,000
ppm (mg/kg)30
ppb (µg/kg)30,000
ppt (ng/kg)30,000,000
%0.003
Guidelines for Canadian Drinking Water Quality (Health Canada)
SubstanceLimit (mg/L)Type
Fluoride1.5Health (MAC)
Nitrate (as nitrate, NO₃⁻) (you)45Health (MAC)
Nitrate (as nitrate-nitrogen)10Health (MAC)
Nitrite (as nitrite, NO₂⁻)3Health (MAC)
Lead0.005Health (MAC)
Arsenic0.010Health (MAC)
Uranium0.02Health (MAC)
Manganese0.12Health (MAC)
Copper2Health (MAC)
Mercury0.001Health (MAC)
Total dissolved solids500Aesthetic (AO)
Chloride250Aesthetic (AO)
Sodium200Aesthetic (AO)
Iron0.1Aesthetic (AO)

MAC: maximum acceptable concentration, set for health. AO: aesthetic objective, for taste, colour or staining.

How This Calculator Works

How It’s Calculated

ppm = mg of solute per kg of solution · mg/L = ppm × density (kg/L)

Your calculation: 30 mg/L at a density of 1 kg/L is 30 mg/L = 30 ppm by mass.

Frequently Asked Questions

What does ppm mean?

Parts per million: one part of a substance in a million parts of the whole. In water it is usually by mass (1 mg of solute per kg of water); in air it is by volume, or equivalently by molecules (1 molecule of the gas per million molecules of air). 1 ppm = 0.0001% = 1000 ppb.

Is 1 ppm the same as 1 mg/L?

For dilute solutions in fresh water, yes, because a litre of water weighs about a kilogram. It stops being true for dense or concentrated solutions: seawater at 35,000 ppm salt is 35,875 mg/L because a litre weighs 1.025 kg. Set the density under Advanced for those. It is never true for gases.

How do I convert ppm to mg/m³ for a gas?

mg/m³ = ppm × molar mass ÷ molar volume. At 25 °C and 1 atm the molar volume is about 24.45 L/mol, so 1000 ppm of CO₂ (44.01 g/mol) is 1,799 mg/m³. At other temperatures and pressures the molar volume changes, which the calculator accounts for.

What are the Canadian drinking water limits?

Health Canada's maximum acceptable concentrations include fluoride 1.5 mg/L, nitrate 45 mg/L as nitrate (10 mg/L as nitrogen), arsenic 0.010 mg/L and lead 0.005 mg/L. Total dissolved solids have an aesthetic objective of 500 mg/L. Provinces adopt these, sometimes with their own additions.

What CO₂ level is acceptable indoors?

Health Canada's residential guideline sets a long-term exposure limit of 1000 ppm as a 24-hour average. Outdoor air is around 420 ppm. Readings well above 1000 ppm are a sign the room needs more ventilation; they are not acutely dangerous at the levels found in homes.

How do I convert EC to ppm for hydroponics?

Multiply the conductivity in mS/cm by your meter's factor. Meters differ: on the 500 scale, 2.0 mS/cm reads 1,000 ppm; on the 700 scale it reads 1,400 ppm. Always quote nutrient strength in EC, or say which scale you used, because the same solution gives different "ppm".

Why is nitrate given "as N" or "as NO₃"?

Labs report nitrate either as the mass of the whole nitrate ion or as the mass of its nitrogen only. One nitrate ion weighs about 4.43 times its nitrogen, so 10 mg/L as nitrogen equals about 44 to 45 mg/L as nitrate; Health Canada sets the limit as 45 and 10 respectively. Check which your report uses before comparing.

What is the difference between ppm, ppb and ppt?

Each is a thousand times smaller than the last: 1 ppm = 1000 ppb (parts per billion) = 1,000,000 ppt (parts per trillion). Trace contaminants such as lead and arsenic are often reported in µg/L, which is ppb in water. Note that "ppt" sometimes means parts per thousand in oceanography.

Water results are parts per million by mass, using the density you enter (1 kg/L by default); gas results are by volume for an ideal gas at the temperature and pressure entered (NIST SP 811 §7.10.3; US EPA conversion). Guidelines are from Health Canada’s Guidelines for Canadian Drinking Water Quality Summary Table (December 2025) and the residential CO₂ guideline (2021); provinces may set their own rules. EC-to-ppm factors are meter conventions, not a standard. It leaves out non-ideal gases, temperature correction of EC readings, hardness and other ion-specific conversions, and it is not a substitute for an accredited lab test or advice from your local health unit.

PPM Calculator: ppm, ppb, mg/L and mg/m³ for Water and Air

By FindMySum · Last reviewed

Water test reports, air quality monitors and hydroponic nutrient meters all speak in parts per million, but they don't always mean the same thing. This ppm calculator converts a concentration between ppm, ppb, ppt, percent, mg/L, µg/L and mg/m³, turns a conductivity reading into ppm, and compares the result with Health Canada's drinking water and indoor CO₂ guidelines.

What ppm means in water and in air

In water, ppm is by mass: 1 ppm is 1 mg of the substance in 1 kg of water. Because a litre of fresh water weighs very nearly a kilogram, 1 ppm ≈ 1 mg/L, which is why water reports switch freely between the two. The exact link is the density of the solution:

mg/L = ppm × density (kg/L)

In air, ppm is by volume: 1 ppm of CO₂ is 1 litre of CO₂ in a million litres of air, which for an ideal gas is the same as one molecule in a million. Converting to a mass per volume needs the gas's molar mass M and its molar volume Vm:

mg/m³ = ppm × M ÷ Vm, with Vm = RT ÷ P

At 25 °C and 1 atm, Vm = 24.47 L/mol (the US EPA rounds it to 24.45).

Worked example: nitrate in well water

The calculator opens with a well water result of 30 mg/L nitrate (as NO₃⁻), common in farm country where fertiliser and manure reach groundwater.

  • At density 1 kg/L: 30 mg/L = 30 ppm = 30,000 ppb = 0.003%
  • Molar mass of NO₃: 14.007 + 3 × 15.999 = 62.004 g/mol, so the molarity is 0.030 ÷ 62.004 = 4.84 × 10⁻⁴ mol/L
  • Health Canada's maximum acceptable concentration for nitrate is 45 mg/L as nitrate, so the sample is at 67% of the limit: below it, but worth retesting, especially if an infant drinks the water.

Canadian drinking water guidelines

The presets come from Health Canada's Guidelines for Canadian Drinking Water Quality Summary Table (December 2025). Maximum acceptable concentrations (health based) include:

SubstanceMAC (mg/L)
Fluoride1.5
Nitrate (as NO₃⁻)45
Nitrate (as N)10
Nitrite (as NO₂⁻)3
Arsenic0.010
Lead0.005
Uranium0.02
Manganese0.12

Aesthetic objectives, for taste and staining, include total dissolved solids 500 mg/L, chloride 250 mg/L, sodium 200 mg/L and iron 0.1 mg/L. For trace metals, labs often report µg/L: 5 µg/L of lead is exactly the 0.005 mg/L limit. Choose the unit on your report and the calculator converts it before comparing.

Indoor CO₂

Choose "A gas in air" for a CO₂ monitor reading. Health Canada's 2021 residential guideline sets a long-term exposure limit of 1000 ppm (1800 mg/m³) averaged over 24 hours, as a marker of adequate ventilation. At 25 °C and 1 atm, 1000 ppm of CO₂ (44.009 g/mol) is 1,799 mg/m³. Change the temperature and pressure for conditions far from room temperature or at altitude.

EC to ppm for hydroponics and aquariums

Conductivity meters measure how well water conducts electricity, which rises with dissolved salts, and many convert it to a "ppm" figure with a fixed factor. Different manufacturers use different factors: 0.5 (the "500" or NaCl scale), 0.64, or 0.7 (the "700" or 442 scale). An EC of 2.0 mS/cm is 1,000 ppm on the 500 scale but 1,400 ppm on the 700 scale. Growers often share nutrient strengths in EC to avoid the confusion.

Molar mass and molarity

Enter a formula (or leave it blank to use the guideline substance) to get the molar mass from standard atomic weights and the molarity in mol/L. For gases, the molar mass is what turns ppm into mg/m³. Charged formulas such as NO3- are accepted.

Limits

Gas conversions assume ideal gas behaviour, which is excellent for air pollutants at everyday conditions. Conductivity depends on temperature and on which salts are dissolved, so EC-to-ppm is an estimate. And a calculation is no substitute for an accredited lab: if a result is near or above a guideline, retest and talk to your local health unit.

More questions

How do I get my well water tested in Canada?

Most provinces and many local public health units offer free or low-cost bacteriological testing of private wells, and accredited private labs test for chemicals such as nitrate, arsenic, uranium and lead. Health Canada suggests testing a private well for bacteria two or three times a year and for chemicals periodically. Your local health unit can tell you which tests matter in your area.

What is the difference between a MAC and an aesthetic objective?

A maximum acceptable concentration (MAC) is set to protect health over a lifetime of drinking the water. An aesthetic objective (AO) is about taste, smell, colour or staining, such as iron leaving orange marks or sodium making water taste salty. Exceeding an AO is a nuisance; exceeding a MAC is a reason to treat the water or use another source.

Does boiling water remove nitrate or lead?

No. Boiling kills bacteria but does not remove dissolved chemicals; it concentrates them slightly as water evaporates. Nitrate, arsenic and lead need treatment such as reverse osmosis, ion exchange or distillation certified for that contaminant, or a different water source. Lead in older homes often comes from plumbing, so flushing the tap and replacing lead service lines helps.

Why do CO₂ monitors read in ppm?

Indoor CO₂ comes mainly from people breathing, so its concentration tracks how well a room is ventilated. Low-cost non-dispersive infrared (NDIR) sensors measure it directly as a volume fraction, which ppm expresses conveniently: outdoor air is around 420 ppm, and a crowded, poorly ventilated room can climb past 2,000 ppm.

What is a mass fraction?

The mass of one component divided by the total mass of the mixture: 0.001 is 0.1% or 1,000 ppm. It is the quantity ppm in water describes. Mass concentration, in mg/L, divides by volume instead; the two are linked by the density of the solution, which is why 1 mg/L equals 1 ppm only when a litre weighs a kilogram.

Sources

This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.

Spotted a wrong result or a bug? Report a problem

May we count your visits with Invoker Analytics? It keeps a random visitor number in your browser. Your calculator inputs are never sent. Privacy policy