Titration Calculator: Unknown Concentration, Equivalence Point and pH Curve
By FindMySum · Last reviewed
A titration measures how much of a solution of known concentration, the titrant, it takes to react completely with a sample, the analyte. From that volume you can work out how concentrated the sample was. In an acid–base titration the pH changes along the way, slowly at first and then very steeply around the equivalence point, which is what an indicator or a pH meter detects. This titration calculator does both halves of the job: it finds an unknown concentration from the endpoint volume, and it draws the full pH curve for four kinds of titration, strong acid with strong base, strong base with strong acid, weak acid with strong base and weak base with strong acid.
Finding an unknown concentration
At the equivalence point the titrant and analyte have reacted in exactly the ratio of the balanced equation. For a·Analyte + t·Titrant:
C_analyte = C_titrant × V_endpoint × (a ÷ t) ÷ V_analyte
Choose "the endpoint volume" in the calculator, enter the burette reading at the colour change, and set the two coefficients. For hydrochloric acid with sodium hydroxide both are 1. For sulfuric acid, H₂SO₄ + 2NaOH → Na₂SO₄ + 2H₂O, the acid's coefficient is 1 and the base's is 2. If 25.00 mL of sulfuric acid needs 30.00 mL of 0.100 M NaOH, the base delivered 3.000 mmol, the acid contained 1.500 mmol, and its concentration is 1.500 ÷ 25.00 = 0.0600 mol/L.
Worked example: vinegar with sodium hydroxide
The calculator opens with 25.00 mL of 0.100 M acetic acid titrated with 0.100 M NaOH, the same titration as the table in OpenStax Chemistry §14.7:
- The flask holds 0.100 × 25.00 = 2.500 mmol of acetic acid, so the equivalence point comes at 25.00 mL of base
- Before any base is added, only the weak acid is present and the pH is 2.88
- At 12.50 mL, half the acid has been converted to acetate, so [HA] = [A⁻] and pH = pKa = 4.75
- At 25.00 mL, the flask holds 0.0500 M sodium acetate, whose hydrolysis gives pH 8.72
- At 37.50 mL, the excess hydroxide sets the pH at 12.30
Phenolphthalein, which turns pink between pH 8 and 10, changes colour right at that steep rise. Methyl red, which changes near pH 5, would turn far too early.
How the pH is worked out
Textbooks usually split a titration curve into four regions and use a different shortcut in each: the weak-acid approximation at the start, Henderson–Hasselbalch in the buffer region, conjugate-base hydrolysis at equivalence and the excess of strong base afterwards. The shortcuts break down near the edges of each region, for very dilute solutions and for fairly strong "weak" acids.
The calculator instead solves the full charge balance at every point. For a weak acid with sodium hydroxide, the positive and negative charges in solution must be equal:
[H⁺] + [Na⁺] = [OH⁻] + [A⁻], with [A⁻] = C·Ka ÷ (Ka + [H⁺]) and [OH⁻] = Kw ÷ [H⁺]
Here C is the total acid concentration and [Na⁺] the base added, both diluted by the total volume. The equation has one physical root, which the calculator finds numerically, so the same calculation is correct at the start, in the buffer region, at equivalence and beyond. The other titrations swap in the matching terms. The results agree with the OpenStax table to the two decimal places it shows.
Strong versus weak
A strong acid titrated with a strong base starts at a lower pH, has no buffer region and passes through pH 7.00 at equivalence, because the salt left behind (sodium chloride) does not react with water. Its jump is steep: for 0.100 M HCl the pH rises from about 3.7 at 24.9 mL to about 10.3 at 25.1 mL. A weak acid starts higher, flattens out in the buffer region around its pKa and has an equivalence point above 7. A weak base titrated with a strong acid mirrors this, with an equivalence point below 7: 0.100 M ammonia reaches pH 5.28. The weaker the acid or base, or the more dilute the solutions, the smaller the jump.
Choosing an indicator
An acid–base indicator is itself a weak acid whose two forms have different colours. It changes colour over roughly its pKa ± 1. The calculator suggests the indicator whose interval contains the equivalence-point pH and whose midpoint is closest to it, from a short list taken from OpenStax: bromophenol blue, bromocresol green, methyl red, bromothymol blue, phenol red, phenolphthalein, thymolphthalein and alizarin yellow R.
Reading the chart and table
The chart plots pH against the titrant volume from zero to twice the equivalence volume, with the equivalence point and your chosen volume marked. The table lists the pH at the start, a quarter, half and three quarters of the way, close to equivalence and past it, with the region of the curve each point belongs to.
Limits
The calculator assumes 25 °C and uses concentrations rather than activities, which is a good approximation below about 0.1 mol/L. The pH curve treats the analyte as monoprotic: a strong diprotic acid such as sulfuric acid counts as two equivalents of H⁺, but polyprotic weak acids such as phosphoric or carbonic acid, which have several equivalence points, are not modelled. Back-titrations, redox and complexometric titrations are out of scope. Ka and Kb values are from the OpenStax appendices, which compile the CRC Handbook.
More questions
What is a primary standard?
A pure, stable substance that can be weighed accurately and used to fix the concentration of a titrant. Potassium hydrogen phthalate (KHP) is the usual primary standard for sodium hydroxide, because NaOH absorbs water and carbon dioxide from the air and can't be weighed out to a known concentration.
Why do I need to rinse the burette with titrant first?
Water left in the burette dilutes the first portion of titrant and lowers its concentration, so you need more of it and the calculated analyte concentration comes out too high. Rinsing with a few millilitres of titrant leaves only titrant on the walls.
How many trials should I do?
Usually a rough trial to find the endpoint, then at least two or three careful trials that agree within about 0.1 mL. Average the concordant results and discard any obvious outlier, such as an overshot endpoint.
Can I titrate without an indicator?
Yes. A pH meter records the whole curve and the equivalence point is the steepest point, where the first derivative peaks. Conductometric titrations follow the change in conductivity instead, which works for coloured or very dilute solutions where an indicator is hard to see.
What is a back-titration?
A known excess of reagent reacts with the analyte, and the unreacted excess is then titrated. It is used when the analyte reacts slowly or is insoluble, such as the carbonate in an antacid tablet. This calculator handles direct titrations only; for a back-titration, subtract the excess you titrate from the amount you added.
Does temperature change a titration?
The stoichiometry doesn't change, but Kw and the acid's Ka do. At 37 °C, Kw is about 2.4 × 10⁻¹⁴, so neutral water has a pH of about 6.8, and the equivalence-point pH of every titration shifts slightly. This calculator uses the values at 25 °C.
Sources
This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.