Wet Bulb Calculator

Find the wet-bulb temperature from air temperature and humidity with the psychrometric equation and Stull’s formula, plus dew point, humidex and heat-stress limits.

Calculator Details

Wet-bulb temperature:23.9 °CSee results ↓

Dry-bulb temperature in the shade

From a weather report or hygrometer

Your Results

Wet-bulb temperature: 23.9 °C

Wet-bulb temperature

23.9 °C

Heat-stress band

Below the measured limits

Below the critical limits measured for young, healthy adults at rest. Heat illness is still possible, especially with exertion, sun, age or illness.

Stull formula

24 °C

Quick fit; typically within −1 to +0.65 °C

Dew point

21.4 °C

Wet-bulb depression 6.13 °C

Humidex

39

Some discomfort.

At 30 °C and 60% humidity the wet-bulb temperature is 23.9 °C (dew point 21.4 °C, humidex 39): below the measured limits.

Compare scenarios

Save these inputs as a scenario, change them, and compare the results side by side.

Loading, available in a moment

Wet-bulb temperature by humidity at 30 °C

Wet-bulb temperature by humidity at 30 °C

Detailed Breakdown

Wet bulb at 30 °C for each humidity
Relative humidityPsychrometric (°C)Stull (°C)
10%13.3812.74
20%15.8315.9
30%18.0718.37
40%20.1520.45
50%22.0822.3
60% (near yours)23.8724
70%25.5425.6
80%27.1227.13
90%28.628.62
100%30—
Wet-bulb heat-stress reference points
Wet bulb fromBandWhat it means
—Below the measured limits (you)Below the critical limits measured for young, healthy adults at rest. Heat illness is still possible, especially with exertion, sun, age or illness.
31 °CAbove the measured critical limitAbove the roughly 31 °C critical wet-bulb measured in warm, humid lab tests on young, healthy adults (Vecellio et al., 2022): body temperature keeps rising even at rest.
35 °CBeyond the survivability limitAt or above 35 °C the body can’t shed heat by sweating at all; Sherwood and Huber (2010) put this as the theoretical limit of survival for more than a few hours.

Informational, not a safety standard or medical advice. Limits are for young, healthy people at rest in shade; older adults, children, people with health conditions and anyone working hard are at risk at much lower wet-bulb temperatures. Follow local heat warnings and talk to your doctor about your own risk.

How This Calculator Works

How It’s Calculated

e = RH × f(p) × e_w(T) · f(p) × e_w(T_w) − 6.53×10⁻⁴ × (1 + 0.000944 T_w) × p × (T − T_w) = e · e_w(t) = 6.112 exp(17.62t ÷ (243.12 + t))

Your calculation: at 30 °C and 60% humidity the air holds 25.52 hPa of water vapour. Solving the psychrometer equation at 101.325 kPa gives a wet bulb of 23.87 °C, 6.13 degrees below the air. Stull’s one-line fit gives 24 °C.

Frequently Asked Questions

What is wet-bulb temperature?

The lowest temperature air can cool a wet surface to by evaporation. It is what a thermometer wrapped in a wet cloth reads in moving air. It is always between the dew point and the air temperature, and equals both when the air is saturated.

How do you calculate wet-bulb temperature?

Precisely, by solving the psychrometer equation, which balances the heat taken by evaporation against the heat supplied by the air; this calculator does that at your pressure. Stull’s 2011 one-line formula is a quick fit: at 20 °C and 50% it gives 13.7 °C against 13.83 °C from the full equation.

Why does wet-bulb temperature matter for health?

People cool down by sweating, and sweat only evaporates if the air can take the moisture. The wet bulb measures how well that works. A wet bulb of 35 °C is the theoretical limit of survival for more than a few hours (Sherwood and Huber, 2010), and lab tests on young, healthy adults found body temperature rising above about 31 °C. Heat illness happens at much lower values, especially with exertion or age.

Is 35 °C wet bulb the same as 35 °C on the thermometer?

No, it is far worse. A 35 °C wet bulb needs air that is both very hot and very humid, such as 40 °C at about 75% humidity. Dry heat feels hot but has a much lower wet bulb: 40 °C at 20% humidity is only about 22.2 °C.

What is the difference between wet-bulb temperature and humidex?

Humidex, used by Environment and Climate Change Canada, is a “feels like” number built from the temperature and dew point. The wet bulb is a physical temperature. The default 30 °C and 60% has a humidex of 39 and a wet bulb of 23.9 °C; 35 °C and 75% has a humidex of 53 and a wet bulb of 31 °C.

What is WBGT?

Wet-bulb globe temperature, used in many workplace and sports heat guidelines, combines the natural wet bulb, a black-globe temperature (for sun) and the air temperature. It needs a globe thermometer or detailed sun and wind data, so it isn’t computed here.

Does altitude change the wet bulb?

Slightly. At lower pressure water evaporates more readily, so the wet bulb is a little lower for the same temperature and humidity. Open the advanced options and enter your station pressure; Stull’s formula assumes sea level.

The main result solves the WMO psychrometer equation (WMO No. 8, Annex 4.B, ventilated Assmann psychrometer) at the pressure you enter; Stull’s 2011 formula is a sea-level fit shown as a check. It is the thermodynamic wet bulb of shaded, ventilated air, not the natural wet bulb or the WBGT used in workplace heat rules, which need sun, wind and a globe thermometer. The heat-stress bands are informational, not medical advice: limits from the research literature apply to young, healthy people at rest, and many people are at risk far below them. Follow Environment and Climate Change Canada heat warnings and talk to your doctor about your own risk.

Wet Bulb Calculator: Wet-Bulb Temperature from Temperature and Humidity

By FindMySum · Last reviewed

The wet bulb is the temperature that evaporation can bring a wet surface down to, and it is the best single number for how well sweating can cool a body. This wet bulb calculator finds it from the air temperature and relative humidity, solving the psychrometric equation used by weather services, and shows Stull's quick formula alongside, with the dew point, the Canadian humidex and the heat-stress limits from recent research.

What the wet bulb measures

Wrap a thermometer bulb in a wet cloth and move air past it. Water evaporates, taking heat with it, and the thermometer falls until the heat drawn from the air balances the heat used by evaporation. That reading is the wet-bulb temperature. In dry air a lot of water can evaporate, so the wet bulb falls far below the air temperature; in saturated air nothing evaporates and the two are equal. The difference is called the wet-bulb depression.

The psychrometric equation

The World Meteorological Organization's guide gives the equation for a ventilated (Assmann) psychrometer:

e = f(p) × e_w(T_w) − 6.53 × 10⁻⁴ × (1 + 0.000944 T_w) × p × (T − T_w)

  • e is the actual vapour pressure of the air (from the relative humidity).
  • e_w(T_w) is the saturation vapour pressure at the wet-bulb temperature, 6.112 × exp(17.62 t ÷ (243.12 + t)) hPa.
  • f(p) is a small correction for moist air at pressure p (hPa).
  • T is the air temperature in °C.

The wet bulb appears on both sides, so the calculator solves it numerically. Because pressure is in the equation, the result is slightly lower at altitude; set the station pressure in the advanced options.

Stull's formula

In 2011 Roland Stull published a single formula fitted to psychrometric results at sea-level pressure:

T_w = T·atan(0.151977·√(RH + 8.313659)) + atan(T + RH) − atan(RH − 1.676331) + 0.00391838·RH^1.5·atan(0.023101·RH) − 4.686035

with T in °C and RH in per cent. It is valid from 5% to 99% humidity and −20 °C to 50 °C, with errors from about −1 °C to +0.65 °C. Stull's own check case is 20 °C at 50% humidity, which gives 13.7 °C; the full equation gives 13.8 °C.

Worked example: the default

At 30 °C and 60% relative humidity at sea level:

  • The air holds about 25.5 hPa of water vapour, so the dew point is 21.4 °C.
  • Solving the psychrometric equation gives a wet bulb of 23.9 °C, 6.1 degrees below the air.
  • Stull's formula gives 24.0 °C.
  • Environment Canada's humidex is 39: some discomfort.

Heat stress and the 35 °C limit

Humans shed heat mainly by sweating, and sweat only cools if it evaporates. When the wet bulb approaches skin temperature, about 35 °C, evaporation stops working. Sherwood and Huber (2010) proposed a wet bulb of 35 °C as the theoretical upper limit for survival over several hours, even for a healthy person resting in the shade with unlimited water.

Laboratory tests at Penn State (Vecellio and colleagues, 2022) found that young, healthy adults doing light activity could not keep their core temperature steady above wet-bulb temperatures of roughly 30–31 °C in warm, humid conditions, well below 35 °C. In hot, dry conditions the limits were lower still. Older adults, children, people with heart or lung conditions, and anyone working or exercising are at risk at far lower values.

The bands on this page mark those two research limits. They are not a safety standard: most heat illness and heat deaths happen at wet-bulb temperatures well below them. Use local heat warnings, and the WBGT index where workplaces or sports bodies require it.

Wet bulb, dew point and humidex

These numbers describe the same air in different ways:

MeasureWhat it is
Dew pointTemperature at which the air becomes saturated if cooled without adding water
Wet bulbTemperature reached by evaporative cooling; between the dew point and the air temperature
HumidexEnvironment Canada's "feels like" index, from temperature and dew point

The table on the page shows the wet bulb at every 10% of humidity for your air temperature, from both methods, so you can see how quickly it climbs in muggy weather.

Limits

This is the thermodynamic wet bulb of shaded, ventilated air. A thermometer in still air or in sunshine reads differently, and workplace heat-stress rules use WBGT, which needs a black-globe thermometer. The WMO formulas cover −45 °C to 60 °C.

For the dew point alone, use the dew point calculator; for the NWS heat index and Canadian humidex, the heat index calculator.

More questions

How do evaporative coolers use the wet bulb?

A swamp cooler blows air through wet pads, and the air leaving can get close to the wet-bulb temperature. In dry climates, where the wet bulb is far below the air temperature, that is a big drop; in humid weather the wet bulb is close to the air temperature and the cooler barely helps.

Why do cooling towers and snowmakers watch the wet bulb?

Both rely on evaporation. A cooling tower can only cool water to a few degrees above the wet bulb, and snow guns need a wet bulb below about −2 °C to make good snow, which is why ski hills can make snow at a slightly positive air temperature when the air is dry.

How was wet-bulb temperature measured before electronics?

With a sling psychrometer: two thermometers mounted side by side, one with a wet cotton sock on its bulb, whirled through the air. The difference between the readings, looked up in psychrometric tables, gave the humidity. Weather stations used ventilated Assmann psychrometers, the instrument the WMO equation here describes.

Where in Canada does the wet bulb get high?

Southern Ontario, southern Quebec and the Prairies on humid summer days can see wet-bulb temperatures in the mid-20s °C, with humidex values around 40. That is well below the survivability limit, but it is enough to cause heat illness, especially for older people, people working outdoors and anyone without air conditioning.

Can the wet bulb be higher than the air temperature?

No. Evaporation can only cool, so the wet bulb is at most equal to the air temperature, when the air is saturated (100% humidity) and nothing can evaporate. It is never lower than the dew point.