Wet Bulb Calculator: Wet-Bulb Temperature from Temperature and Humidity
By FindMySum · Last reviewed
The wet bulb is the temperature that evaporation can bring a wet surface down to, and it is the best single number for how well sweating can cool a body. This wet bulb calculator finds it from the air temperature and relative humidity, solving the psychrometric equation used by weather services, and shows Stull's quick formula alongside, with the dew point, the Canadian humidex and the heat-stress limits from recent research.
What the wet bulb measures
Wrap a thermometer bulb in a wet cloth and move air past it. Water evaporates, taking heat with it, and the thermometer falls until the heat drawn from the air balances the heat used by evaporation. That reading is the wet-bulb temperature. In dry air a lot of water can evaporate, so the wet bulb falls far below the air temperature; in saturated air nothing evaporates and the two are equal. The difference is called the wet-bulb depression.
The psychrometric equation
The World Meteorological Organization's guide gives the equation for a ventilated (Assmann) psychrometer:
e = f(p) × e_w(T_w) − 6.53 × 10⁻⁴ × (1 + 0.000944 T_w) × p × (T − T_w)
- e is the actual vapour pressure of the air (from the relative humidity).
- e_w(T_w) is the saturation vapour pressure at the wet-bulb temperature, 6.112 × exp(17.62 t ÷ (243.12 + t)) hPa.
- f(p) is a small correction for moist air at pressure p (hPa).
- T is the air temperature in °C.
The wet bulb appears on both sides, so the calculator solves it numerically. Because pressure is in the equation, the result is slightly lower at altitude; set the station pressure in the advanced options.
Stull's formula
In 2011 Roland Stull published a single formula fitted to psychrometric results at sea-level pressure:
T_w = T·atan(0.151977·√(RH + 8.313659)) + atan(T + RH) − atan(RH − 1.676331) + 0.00391838·RH^1.5·atan(0.023101·RH) − 4.686035
with T in °C and RH in per cent. It is valid from 5% to 99% humidity and −20 °C to 50 °C, with errors from about −1 °C to +0.65 °C. Stull's own check case is 20 °C at 50% humidity, which gives 13.7 °C; the full equation gives 13.8 °C.
Worked example: the default
At 30 °C and 60% relative humidity at sea level:
- The air holds about 25.5 hPa of water vapour, so the dew point is 21.4 °C.
- Solving the psychrometric equation gives a wet bulb of 23.9 °C, 6.1 degrees below the air.
- Stull's formula gives 24.0 °C.
- Environment Canada's humidex is 39: some discomfort.
Heat stress and the 35 °C limit
Humans shed heat mainly by sweating, and sweat only cools if it evaporates. When the wet bulb approaches skin temperature, about 35 °C, evaporation stops working. Sherwood and Huber (2010) proposed a wet bulb of 35 °C as the theoretical upper limit for survival over several hours, even for a healthy person resting in the shade with unlimited water.
Laboratory tests at Penn State (Vecellio and colleagues, 2022) found that young, healthy adults doing light activity could not keep their core temperature steady above wet-bulb temperatures of roughly 30–31 °C in warm, humid conditions, well below 35 °C. In hot, dry conditions the limits were lower still. Older adults, children, people with heart or lung conditions, and anyone working or exercising are at risk at far lower values.
The bands on this page mark those two research limits. They are not a safety standard: most heat illness and heat deaths happen at wet-bulb temperatures well below them. Use local heat warnings, and the WBGT index where workplaces or sports bodies require it.
Wet bulb, dew point and humidex
These numbers describe the same air in different ways:
| Measure | What it is |
|---|---|
| Dew point | Temperature at which the air becomes saturated if cooled without adding water |
| Wet bulb | Temperature reached by evaporative cooling; between the dew point and the air temperature |
| Humidex | Environment Canada's "feels like" index, from temperature and dew point |
The table on the page shows the wet bulb at every 10% of humidity for your air temperature, from both methods, so you can see how quickly it climbs in muggy weather.
Limits
This is the thermodynamic wet bulb of shaded, ventilated air. A thermometer in still air or in sunshine reads differently, and workplace heat-stress rules use WBGT, which needs a black-globe thermometer. The WMO formulas cover −45 °C to 60 °C.
For the dew point alone, use the dew point calculator; for the NWS heat index and Canadian humidex, the heat index calculator.
More questions
How do evaporative coolers use the wet bulb?
A swamp cooler blows air through wet pads, and the air leaving can get close to the wet-bulb temperature. In dry climates, where the wet bulb is far below the air temperature, that is a big drop; in humid weather the wet bulb is close to the air temperature and the cooler barely helps.
Why do cooling towers and snowmakers watch the wet bulb?
Both rely on evaporation. A cooling tower can only cool water to a few degrees above the wet bulb, and snow guns need a wet bulb below about −2 °C to make good snow, which is why ski hills can make snow at a slightly positive air temperature when the air is dry.
How was wet-bulb temperature measured before electronics?
With a sling psychrometer: two thermometers mounted side by side, one with a wet cotton sock on its bulb, whirled through the air. The difference between the readings, looked up in psychrometric tables, gave the humidity. Weather stations used ventilated Assmann psychrometers, the instrument the WMO equation here describes.
Where in Canada does the wet bulb get high?
Southern Ontario, southern Quebec and the Prairies on humid summer days can see wet-bulb temperatures in the mid-20s °C, with humidex values around 40. That is well below the survivability limit, but it is enough to cause heat illness, especially for older people, people working outdoors and anyone without air conditioning.
Can the wet bulb be higher than the air temperature?
No. Evaporation can only cool, so the wet bulb is at most equal to the air temperature, when the air is saturated (100% humidity) and nothing can evaporate. It is never lower than the dew point.
Sources
- WMO Guide to Instruments and Methods of Observation (WMO-No. 8), Volume I, Chapter 4: Measurement of humidity (Annex 4.B)
- Stull, R. (2011), Wet-Bulb Temperature from Relative Humidity and Air Temperature, J. Appl. Meteor. Climatol. 50, 2267–2269
- Sherwood, S.C. and Huber, M. (2010), An adaptability limit to climate change due to heat stress, PNAS 107(21)
- Vecellio et al. (2022), Evaluating the 35 °C wet-bulb temperature adaptability threshold for young, healthy subjects, J. Appl. Physiol.
This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.