Skip to content

Battery Life Calculator

How long a battery will last on a load, or what capacity you need, with depth of discharge, Peukert’s law and cold-weather derating, plus power bank phone charges.

Calculator Details

Runtime:4.73 hSee results ↓

How long a battery lasts, the battery size you need, or phone charges from a power bank

Fills in typical values you can change

Sets the usable depth of discharge and Peukert exponent

Rated amp-hours (mAh ÷ 1,000)

12 V for most RV, cabin and sump-pump batteries; 3.7 V for a lithium cell

Watts, amps, or an electronics duty cycle (active and sleep current)

Power of everything running

Directly (12 V DC) or through an inverter (120 V AC)

Cold batteries deliver less: lead-acid about 80% at 0 °C

Your Results

Runtime: 4.73 h

Runtime

4.73 h

100 Ah AGM lead-acid at 20 °C

Load current

9.259 A

100 W through a 90% inverter

Usable energy

576 Wh

50% depth of discharge, 96% capacity at 20 °C

A 100 Ah, 12 V agm lead-acid battery runs 100 W through a 90% inverter (9.259 A) for about 4.73 hours at 20 °C, using 50% of its capacity.

Compare scenarios

Save these inputs as a scenario, change them, and compare the results side by side.

Loading, available in a moment

Runtime at lighter and heavier loads

Runtime at lighter and heavier loads

Detailed Breakdown

Runtime by load (Peukert)
LoadCurrent (A)Runtime
25% of your load2.31523.28 h
50% of your load4.6310.49 h
Your load9.2594.73 h
150% of your load13.8892.96 h
200% of your load18.5192.13 h

Peukert exponent 1.15: heavier loads drain agm lead-acid disproportionately faster.

How This Calculator Works

How battery life is calculated

Current I = watts ÷ (volts × inverter efficiency)

Time to empty t = H × (C ÷ (I × H))^k (Peukert); runtime = t × depth of discharge × cold factor

Your numbers: I = 9.259 A; t = 20 × (100 ÷ (9.259 × 20))^1.15; × 50% × 0.96 = 4.73 h.

Frequently Asked Questions

How long will a 100 Ah battery last?

It depends on the load and the battery type. A 12 V, 100 Ah AGM battery holds 1,200 Wh, but only about half should be used for a long life. Running 100 W through an inverter draws about 9.3 A and lasts roughly 4.7 hours at room temperature; a 20 W load lasts more than a day.

How do I convert amp-hours to watt-hours?

Multiply by the voltage: a 100 Ah battery at 12 V stores 1,200 Wh, and a 5,000 mAh (5 Ah) power bank at 3.7 V stores 18.5 Wh. Watt-hours let you compare batteries of different voltages.

How deep can I discharge a battery?

For a long life, flooded and AGM lead-acid batteries should be discharged to about 50% and recharged promptly; going deeper shortens their life sharply. Lithium iron phosphate batteries can routinely use 90% or more, which is why a smaller lithium battery can replace a larger lead-acid one.

What is Peukert’s law?

Lead-acid batteries deliver less of their rated capacity when discharged quickly. Peukert’s law, t = H × (C ÷ (I × H))^k, captures this with an exponent k: about 1.25 for flooded lead-acid and 1.15 for AGM, but only about 1.05 for lithium. Capacity is usually rated over 20 hours (C20).

How does cold weather affect batteries?

Cold slows the chemistry. A lead-acid battery delivers roughly 80% of its rated capacity at 0 °C and about 60% at −20 °C, and lithium batteries lose less. A discharged lead-acid battery can also freeze. Keep batteries in an insulated box or a heated space in a Canadian winter, and never charge lithium iron phosphate below 0 °C without a heater.

How long will a sump pump backup battery last?

A pump that draws 8 to 10 A while running only runs part of the time. Multiply its running current by the share of time it runs to get the average current; at an average of 8 A, a 100 Ah AGM battery gives about 5 to 6 hours. During heavy rain the pump may run continuously, so larger or multiple batteries are common.

How many times can a power bank charge my phone?

Power banks are rated in mAh at their 3.7 V cell voltage, and about 85% of that energy reaches the phone after voltage conversion. A 10,000 mAh bank (37 Wh) charges a 4,500 mAh phone battery (about 17 Wh) roughly 1.8 times.

Peukert's law as in Linden's Handbook of Batteries; depths of discharge, Peukert exponents, cold-temperature factors and power bank efficiency are typical values from maker guides (still being checked), so use your battery's data sheet when you have it. It assumes a steady (or averaged) load, a fully charged healthy battery and a linear cold derating, and leaves out battery ageing, self-discharge, voltage sag and low-voltage cut-offs, inverter idle draw, motor start-up surges, charge sources such as solar or an alternator, and battery management system limits.

Battery Life Calculator: Runtime, Capacity and Power Bank Charges

By FindMySum · Last reviewed

Whether it's a cabin lighting system, an RV, a sump-pump backup or a small sensor, the question is the same: how long will this battery last on this load? The quick answer, capacity divided by current, is usually too optimistic. This calculator adds the three things that matter most: how much of the battery you can actually use, how heavier loads drain it faster, and how cold reduces capacity.

Step 1: the load current

Batteries are rated in amp-hours, so start with the current the load draws:

current (A) = load (W) ÷ (battery voltage × inverter efficiency)

If you run a 120 V appliance through an inverter, the inverter wastes some energy, typically 10%. A 100 W load on a 12 V battery through a 90% inverter draws 100 ÷ (12 × 0.9) = 9.26 A. For electronics that sleep most of the time, use the average current: active current × share of time active + sleep current × the rest.

Step 2: usable capacity

Using a battery's full rated capacity shortens its life. Lead-acid batteries, flooded or AGM, are usually discharged to about 50%; lithium iron phosphate (LiFePO4) to about 90%; lithium-ion cells in tools and electronics to about 80%.

Cold reduces the capacity a battery can deliver. Lead-acid batteries give roughly 80% at 0 °C and 60% at −20 °C; lithium batteries hold up better. In a Canadian winter, a battery in an unheated shed or cabin may deliver much less than its label says.

Step 3: Peukert's law

Lead-acid batteries deliver less total energy when discharged quickly. Battery capacity is rated at a set discharge time, usually 20 hours (C20), and Peukert's law adjusts for other rates:

time to empty t = H × (C ÷ (I × H))^k

where C is the rated capacity, H the rating period and k the Peukert exponent: about 1.25 for flooded lead-acid, 1.15 for AGM and close to 1.05 for lithium. Then:

runtime = t × depth of discharge × cold factor

Worked example (the default). A 100 Ah, 12 V AGM battery running 100 W through an inverter: 9.26 A. t = 20 × (100 ÷ 185.2)^1.15 = 9.85 hours to empty. Using 50% at 20 °C (a cold factor of 0.96): about 4.7 hours. Simple division would have said 100 ÷ 9.26 × 0.5 = 5.4 hours.

Sizing a battery

Turn the formula around to find the capacity you need for a runtime. To run a 5 A load for 24 hours on AGM at 20 °C, the battery must last 24 ÷ (0.5 × 0.96) = 50 hours to empty, which takes about 222 Ah: in practice, two 12 V 100 Ah or 120 Ah batteries in parallel, or a single lithium battery of about 130 Ah, because you can use more of it.

Power banks

Power banks are rated in mAh at their internal cell voltage of 3.6–3.7 V, while phones charge at about 3.85 V, and voltage conversion loses roughly 15%. A 10,000 mAh bank stores 37 Wh and delivers about 31 Wh; a 4,500 mAh phone battery holds about 17 Wh, so you get roughly 1.8 full charges.

Safety

Charge batteries with a charger made for their chemistry, ventilate flooded lead-acid batteries (they release hydrogen when charging), and never charge LiFePO4 below 0 °C unless it has a heater. Use fuses rated for the wiring, and replace swollen or damaged lithium batteries.

What the calculator leaves out

Battery ageing, self-discharge, voltage cut-offs, motor start-up surges, inverter standby draw, and recharging from solar panels or an alternator. The solar panel calculator sizes the panels to recharge a system.

More questions

Is a bigger battery always better?

For runtime, yes, but weight, space and cost grow with it, and lead-acid batteries that sit partly charged for long periods sulphate and lose capacity. Size the battery for the runtime you need with some margin, and make sure you can recharge it fully: a battery that never gets a full charge wears out early.

Can I connect batteries together?

In parallel (positive to positive), capacity adds at the same voltage: two 12 V 100 Ah batteries make 12 V 200 Ah. In series (positive to negative), voltage adds: two 12 V batteries make 24 V at 100 Ah. Use identical batteries of the same age and charge, and fuse the connections.

Why does my battery run out sooner than calculated?

Common reasons are an older battery that has lost capacity, a load that draws more than its label says (especially motors and compressors when they start), inverter standby draw, cold, and a battery that wasn't fully charged. Measure the real current with a clamp meter or battery monitor and update the calculation.

What does mAh mean on a battery?

Milliamp-hours: a 3,000 mAh battery can in principle supply 3,000 mA for one hour, or 300 mA for ten hours. Because the voltage matters too, compare batteries in watt-hours (mAh × volts ÷ 1,000).

How long do deep-cycle batteries last?

Lead-acid deep-cycle batteries typically last a few hundred cycles at 50% depth of discharge, more when discharged less deeply; lithium iron phosphate batteries are usually rated for 2,000 to 6,000 cycles. Heat, deep discharges and leaving batteries discharged shorten life. Check the cycle rating on the data sheet.

Sources

This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.

Spotted a wrong result or a bug? Report a problem

May we count your visits with Invoker Analytics? It keeps a random visitor number in your browser. Your calculator inputs are never sent. Privacy policy