Exposure Calculator: EV, Equivalent Exposures, ND Filters and Sunny 16
By FindMySum · Last reviewed
An exposure calculator works out camera settings that give the right amount of light. This one gives the exposure value (EV) of an aperture and shutter speed, finds the equivalent exposure when you change the aperture, ISO or add a neutral density (ND) filter, gives sunny 16 starting points when you have no meter, and corrects long film exposures for reciprocity failure.
Stops and exposure value
Photographic exposure is counted in stops: each stop doubles or halves the light. Three settings control it:
- Aperture (f-number N): the light through the lens falls with the square of the f-number, so f/8 to f/11 (a factor of √2) is one stop less light.
- Shutter speed (t): twice as long is one stop more light.
- ISO: twice the ISO needs one stop less light for the same picture brightness.
Exposure value combines the first two into one number: EV = log₂(N²/t). It is the APEX system used in the ISO standard for exposure meters. f/16 at 1/125 s is EV 14.97; f/8 at 1/500 s is the same EV, the same amount of light. At a fixed ISO of 100, the EV needed for a correct exposure also measures the scene's brightness, which is why light meters quote their range as "EV −2 to 20 at ISO 100". At another ISO, subtract log₂(ISO/100) to get the scene's EV at ISO 100.
Equivalent exposures
To change one setting and keep the same brightness, change another by the same number of stops the opposite way. The calculator does this with one formula:
t′ = t × (N′/N)² × (ISO/ISO′) × filter factor
Opening from f/16 to f/8 is (8/16)² = 1/4 of the time, two stops: 1/125 s becomes 1/500 s. Raising ISO from 400 to 1600 is two stops, so 1/60 s becomes 1/240 s, shown as 1/250, the nearest speed most cameras offer. The table under the result gives the shutter speed for every full-stop aperture from f/1.4 to f/22.
Long exposures with ND filters
Neutral density filters darken the whole picture evenly so you can use a slow shutter in daylight to blur water or clouds. They are labelled three ways:
- Optical density: ND 0.3, 0.6, 0.9, 3.0. The filter passes 10^(−density) of the light.
- Filter factor: ND2, ND4, ND8, ND1000, the number to multiply the time by.
- Stops: 1, 2, 3, 10. Density ÷ 0.301 gives the stops.
The density and factor labels agree exactly (10³ = 1,000), but the stop label is rounded: ND 3.0 is 9.97 stops, not 10, so a strict 10-stop calculation (×1,024) gives times about 2% longer. That's within the tolerance of most filters. The calculator uses the density.
Worked example: you meter f/8 at 1/125 s at ISO 100 and fit an ND 3.0 filter. The new time is 1/125 × 1,000 = 8 seconds.
The sunny 16 rule
Without a meter, start from the light. Kodak's film data sheets give a daylight table for average front-lit subjects from two hours after sunrise to two hours before sunset; at ISO 100 and 1/125 s it reads:
- bright sun on sand or snow: f/22
- bright or hazy sun with distinct shadows: f/16
- weak, hazy sun with soft shadows: f/11
- cloudy bright, no shadows: f/8
- heavy overcast or open shade: f/5.6
The rule generalises to any ISO by setting the shutter to 1 over the ISO. At ISO 400 in heavy overcast, that is f/5.6 at 1/400 s, which you can then convert to any equivalent exposure. Kodak calls the table a guide: backlit subjects and dark or very light subjects need adjustment.
Reciprocity failure on film
The reciprocity law says that halving the light and doubling the time gives the same exposure. Film obeys it for ordinary times but not for long exposures: the emulsion becomes less efficient, so a metered 10-second exposure comes out too dark. ILFORD publishes a simple correction for its black-and-white films:
corrected time = metered time^P
with P = 1.31 for HP5 PLUS, 1.26 for FP4 PLUS and DELTA 100, and 1.33 for PAN F PLUS, for metered times over one second. A metered 10 seconds on HP5 PLUS becomes 10^1.31 ≈ 20 seconds. Digital sensors don't show reciprocity failure.
Putting it together
A typical long-exposure workflow is: meter the scene without the filter (or use sunny 16), choose the aperture you want for depth of field, enter the filter, and read off the new time. On film, apply the reciprocity correction to times over a second. Bracket a stop either way when the light is changing or the subject is unusual.
More questions
What EV is a typical scene?
At ISO 100, full sun is around EV 15, an overcast day about EV 12 to 13, a bright office around EV 8, a home interior at night EV 5 to 7, and a city street at night EV 3 to 5. A full moon landscape is near EV −2. Light meters and camera specifications often quote their working range in EV.
Why does my camera say 1/250 when the calculator says 1/240?
Cameras offer speeds in thirds of a stop (1/200, 1/250, 1/320), so the calculator also shows the nearest standard speed. The difference between 1/240 and 1/250 is about a twentieth of a stop, far below what you can see in a picture.
Should I meter with the ND filter on?
With light ND filters many cameras meter through the filter correctly. With very dark filters (6 stops and more) the meter and autofocus struggle, so meter and focus without the filter, switch to manual, then fit the filter and calculate the new time, as this calculator does.
Do lenses with the same f-number give the same exposure?
Nearly. The f-number sets how much light reaches the sensor per unit area, so f/4 on a phone, a full-frame camera or a medium-format camera gives the same exposure. Lenses lose a little light inside the glass; cine lenses are marked in T-stops, which include that loss.
What is the difference between EV and exposure compensation?
EV describes a combination of settings or a scene's brightness. Exposure compensation, such as +1 EV, tells the camera to make the picture one stop brighter than its meter suggests, for example on a snowy scene the meter would make grey.
Sources
This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.