Stair Calculator (IRC 2021, Inches)

Enter the total rise from floor to floor and the run per step in inches to get the number of risers and treads, the riser height, the stringer length and the angle, checked against the International Residential Code.

Calculator Details

Steps:14 risers of 7.5 inSee results ↓

The code and stair type to check against

Millimetres or inches for every measurement below

Vertical height from finished floor to finished floor

Horizontal distance from one riser to the next (nosing to nosing)

Clear height above the stair, measured vertically from the line of the nosings

Clear width between walls or handrails

Your Results

Steps: 14 risers of 7.5 in

Steps

14 risers of 7.5 in

13 treads · Meets IRC 2021: one- and two-family dwellings (US)

Passes the checks belowRiser, run, headroom and width are within IRC 2021: one- and two-family dwellings (US).

Layout

Riser height

7.5 in

Run per step

10.5 in

Total run

136.5 in

Stringer length

172.213 in

along the slope, before cuts

Angle

35.5°

Side view to scale: 14 risers, 13 treads; the dashed line is the slope of the stringer.

A 105 in rise needs 14 risers of 7.5 in and 13 treads, a total run of 136.5 in at 35.5°. It meets the IRC 2021: one- and two-family dwellings (US) limits checked here.

Compare scenarios

Save these inputs as a scenario, change them, and compare the results side by side.

Loading, available in a moment

Detailed Breakdown

Code checks for IRC 2021: one- and two-family dwellings (US)
CheckYoursLimitResult
Riser height (maximum)7.5 in7.75 in✓ Pass
Run (minimum)10.5 in10 in✓ Pass
Headroom (minimum)80 in80 in✓ Pass
Width (minimum)36 in36 in✓ Pass

How This Calculator Works

How the Stair Is Laid Out

Risers = ⌈total rise ÷ maximum riser⌉
Riser height = total rise ÷ risers · Treads = risers − 1
Total run = treads × run · Stringer = √(rise² + run²)

Your calculation: 105 ÷ 7.75 in maximum, rounded up = 14 risers of 7.5 in. 13 treads × 10.5 = 136.5 in. Stringer: √(105² + 136.5²) = 172.213 in.

Frequently Asked Questions

How many steps do I need for a 105 inch rise?

14 risers of 7½ inches. The IRC caps a riser at 7¾ inches, and 105 ÷ 7.75 = 13.5, so you round up to 14 risers, which makes each one exactly 7.5 inches. A stair has one tread fewer than risers, so 13 treads.

How long is the stringer for 14 steps?

With 13 treads of 10½ inches the total run is 136½ inches, and the stringer runs along the hypotenuse: √(105² + 136.5²) ≈ 172.2 inches, a little over 14 ft 4 in. Buy 16 ft boards to leave room for the cuts at the top and bottom.

What is the 7-11 rule for stairs?

A rule of thumb for comfortable stairs: a riser of about 7 inches and a tread of about 11 inches. It sits inside the IRC limits and is close to the public-stair limits in the International Building Code (7 in maximum rise, 11 in minimum tread). Another check is that two risers plus one tread should come to about 24 to 25 inches.

Does OSHA set stair rules for homes?

No. OSHA's stair rules (29 CFR 1910.25 for workplaces and 1926.1052 for construction) cover employers, including temporary stairs on a job site. A house is governed by the residential code your state or city has adopted, usually a version of the IRC with local amendments.

Your local code and building official decide. Provinces, states and cities adopt these model codes with amendments. This checks straight flights with rectangular treads only: rise, run, headroom and width. Not checked: winders and curved stairs, landings, nosings and tread depth, handrails, guards, openings between balusters, riser uniformity, lighting and fire separations.

NBC 2020 (same in NBC 2025): stairs within a dwelling unit (private): National Building Code of Canada 2020, Division B, Part 9: Table 9.8.4.1 (rise 125–200 mm, run 255–355 mm for stairs within dwelling units), Sentence 9.8.2.2.(1) (headroom 1 950 mm for stairs within dwelling units), Sentence 9.8.2.1.(2) (width 860 mm). The NBC 2020 raised the minimum run for dwelling-unit stairs to 255 mm.

NBC 2020 (same in NBC 2025): public stairs (Part 9 buildings): National Building Code of Canada 2020, Division B, Part 9: Table 9.8.4.1 (public stairs: rise 125–180 mm, run 280 mm minimum, no maximum), Sentence 9.8.2.2.(1) (headroom 2 050 mm). Required width depends on the occupant load (Subsection 9.8.2), so it is not checked.

IRC 2021: one- and two-family dwellings (US): International Residential Code 2021, Section R311.7: R311.7.5.1 (riser height 7¾ in maximum), R311.7.5.2 (tread depth 10 in minimum, nosing to nosing), R311.7.2 (headroom 6 ft 8 in), R311.7.1 (width 36 in minimum above the handrail height).

Stair Calculator: Risers, Treads and Stringers to IRC 2021 (US)

By FindMySum · Last reviewed

This stair calculator lays out a straight run of stairs in inches and checks it against the International Residential Code 2021, the model code most US states and cities adopt for one- and two-family houses. From the total rise, floor to finished floor, it finds the fewest risers that keep each one at or under the code maximum, divides the rise evenly between them, multiplies the treads by your run to get the total run, and works out the stringer length and the angle.

Worked example: a basement stair with a 105 inch rise

The US page starts with a total rise of 105 inches, a run of 10½ inches per step, 80 inches of headroom and a width of 36 inches, checked against IRC 2021 R311.7.

  1. Risers: 105 ÷ 7.75 = 13.5, so 14 risers of 105 ÷ 14 = 7.5 inches.
  2. Treads: 14 − 1 = 13, at 10.5 inches each, for a total run of 136.5 inches.
  3. Stringer: √(105² + 136.5²) = about 172.2 inches.
  4. Angle: about 35.5 degrees.

Every check passes: the riser is under 7¾ inches, the tread is over 10 inches, the headroom is the 6 ft 8 in minimum and the width is the 36 inch minimum.

What the IRC asks for, beyond the numbers here

R311.7 also limits the variation between the tallest and shortest riser, and between the deepest and shallowest tread, to ⅜ inch in a flight, which is why an even layout matters. Treads with solid risers need a nosing of ¾ to 1¼ inches when the tread is under 11 inches. A flight with four or more risers needs a handrail on at least one side, 34 to 38 inches above the nosings, and open sides more than 30 inches above the floor need a guard. Some states and cities amend these numbers, and many local inspectors check the first and last riser carefully, because a floor finish added later changes them.

Measuring the total rise

Measure from the finished floor at the bottom to the finished floor at the top, not from the subfloor or the concrete. If a basement slab will get tile or the upper floor hardwood, add the finish thickness now. A level and a straight board across the opening give a better number than a tape against a wall that may not be plumb.

For millimetres and the National Building Code of Canada limits, use the stair calculator.

Sources

This article explains how the calculator works and is general information, not financial, tax or legal advice. Rules change; check the sources above or a qualified professional before you act.

Spotted a wrong result or a bug? Report a problem

May we count your visits with Invoker Analytics? It keeps a random visitor number in your browser. Your calculator inputs are never sent. Privacy policy