Skip to content

Viscosity Converter

Convert between cP, cSt, Pa·s, mPa·s, m²/s, poise, stokes and Saybolt seconds, with density for dynamic ↔ kinematic

Calculator Details

100 cP =114.943 cStSee results ↓

The viscosity to convert, in the From unit. Decimals are allowed.

Needed only between dynamic (cP, Pa·s) and kinematic (cSt, m²/s) viscosity, at the same temperature as the viscosity. 870 kg/m³ is a typical mineral oil; water is about 998 kg/m³ at 20 °C.

Your Results

100 cP = 114.943 cSt

100 cP =

114.943 cSt

Dynamic to kinematic viscosity at a density of 870 kg/m³

  • Kinematic viscosity

    114.9425287 cSt (mm²/s)

  • Dynamic viscosity

    100 cP (mPa·s)

100 cP = 114.943 cSt at a density of 870 kg/m³

Detailed Breakdown

100 cP in every viscosity unitDynamic and kinematic values are linked by the density (870 kg/m³); SUS is at 100 °F.
UnitTypeValue
Pascal second (Pa·s)Dynamic0.1 Pa·s
Millipascal second (mPa·s)Dynamic100 mPa·s
Centipoise (cP) (from)Dynamic100 cP
Poise (P)Dynamic1 P
Pound per foot second (lb/(ft·s))Dynamic0.0671969 lb/(ft·s)
Pound-force second per sq ft (lbf·s/ft²)Dynamic0.00208854 lbf·s/ft²
Square metre per second (m²/s)Kinematic0.000114943 m²/s
Square millimetre per second (mm²/s)Kinematic114.943 mm²/s
Centistokes (cSt) (your answer)Kinematic114.943 cSt
Stokes (St)Kinematic1.14943 St
Square foot per second (ft²/s)Kinematic0.00123723 ft²/s
Saybolt Universal seconds (SUS, SSU)Saybolt (empirical)532.626 SUS

1 cP = 1 mPa·s and 1 cSt = 1 mm²/s exactly. Rounded to 6 significant figures.

Water at atmospheric pressure (examples)Viscosity falls fast as water warms. Use a row to load its dynamic viscosity and density into the converter.
Temperature, densityDynamicKinematicLoad
0.01 °C999.84 kg/m³1.7911 cP1.79139 cSt
10 °C999.7 kg/m³1.3059 cP1.30629 cSt
20 °C998.21 kg/m³1.0016 cP1.0034 cSt
25 °C997.05 kg/m³0.89002 cP0.892653 cSt
40 °C992.22 kg/m³0.65273 cP0.657848 cSt
60 °C983.2 kg/m³0.46604 cP0.474003 cSt
80 °C971.79 kg/m³0.35405 cP0.364328 cSt
99.974 °C958.37 kg/m³0.28166 cP0.293895 cSt

NIST Chemistry WebBook (IAPWS-95 density, IAPWS 2008 viscosity) at 0.101325 MPa; 0.01 °C is the triple point and 99.974 °C the boiling point.

Engine oil grades: kinematic viscosity at 100 °C (SAE J300_202104)Each grade’s range at 100 °C (the upper limit is “less than”); the second number of a multigrade (the 30 in 5W-30) uses the same range. Use loads the middle of the range in cSt; the density is not set.
GradecSt at 100 °CLoad
SAE 84 to < 6.1
SAE 125 to < 7.1
SAE 166.1 to < 8.2
SAE 206.9 to < 9.3
SAE 309.3 to < 12.5
SAE 4012.5 to < 16.3
SAE 5016.3 to < 21.9
SAE 6021.9 to < 26.1

SAE J300 also sets low-temperature (W grade) and high-temperature high-shear limits, not shown. A grade is a range: check the oil’s data sheet for its measured viscosity.

How This Calculator Works

How It’s Calculated

kinematic viscosity ν = dynamic viscosity μ ÷ density ρ
ν (cSt) = μ (cP) ÷ ρ (g/cm³)
SUS at 100 °F = 4.6324ν + (1 + 0.03264ν) ÷ [(3930.2 + 262.7ν + 23.97ν² + 1.646ν³) × 10⁻⁵]
SUS at t °F = SUS at 100 °F × [1 + 0.000061 × (t − 100)]

Your numbers: 100 cP is 100 mPa·s of dynamic viscosity and 114.9425287 mm²/s of kinematic viscosity (100 ÷ 0.87 g/cm³ = 114.9425287 cSt), so the answer is 114.943 cSt.

Unit factors are exact (NIST SP 811, 2008, Appendix B.8): 1 P = 0.1 Pa·s, 1 cP = 1 mPa·s, 1 St = 10⁻⁴ m²/s, 1 cSt = 1 mm²/s, 1 ft²/s = 0.09290304 m²/s, 1 lb/(ft·s) = 1.48816 Pa·s, 1 lbf·s/ft² = 47.8803 Pa·s. The Saybolt conversion is the empirical equation of ASTM D2161-20 (reapproved 2025), valid from 1.82 cSt (about 32 SUS) and from 0 to 350 °F. Results are rounded to 6 significant figures.

Frequently Asked Questions

How do I convert cP to cSt?

Divide the dynamic viscosity in centipoise by the density in g/cm³: cSt = cP ÷ ρ. An oil of 100 cP with a density of 0.87 g/cm³ is 100 ÷ 0.87 = 114.9 cSt. Going the other way, multiply: cP = cSt × ρ. Use the density at the same temperature as the viscosity.

What is the difference between dynamic and kinematic viscosity?

Dynamic (absolute) viscosity, in Pa·s or centipoise, is a fluid’s resistance to shearing: how much force it takes to slide one layer over another. Kinematic viscosity, in m²/s or centistokes, is dynamic viscosity divided by density, and describes how fast a fluid flows under its own weight. Rotational viscometers measure dynamic viscosity; glass capillary viscometers (ASTM D445), used for oils, measure kinematic viscosity.

Is a centipoise the same as a mPa·s?

Yes, exactly. One poise is 0.1 Pa·s, so one centipoise is 0.001 Pa·s, one millipascal second. Likewise one centistokes is exactly one mm²/s. Water at 20 °C is about 1.0 cP and 1.0 cSt, which is why the old CGS units are still popular.

How do I convert SUS to cSt?

With the ASTM D2161 equation, which this converter solves for you. There is no single factor because the Saybolt scale is not linear at low viscosities: 32 SUS is 1.82 cSt, 100 SUS is about 20.5 cSt and 700 SUS about 151.1 cSt (at 100 °F). Above about 75 cSt the standard allows the shortcut SUS = 4.632 × cSt at 100 °F.

Why do I need a density to convert viscosity?

Only when you cross between dynamic units (cP, Pa·s, poise) and kinematic units (cSt, m²/s, stokes, SUS), because kinematic viscosity is dynamic viscosity divided by density. Conversions within one group, such as cP to Pa·s or cSt to stokes, are fixed factors and ignore the density.

What temperature should the Saybolt reading be at?

The same temperature as the kinematic viscosity: a Saybolt time and a cSt value describe the oil at one temperature, traditionally 100 °F (37.8 °C) or 210 °F (98.9 °C). ASTM D2161 corrects for other temperatures between 0 and 350 °F with the factor 1 + 0.000061 × (t − 100). Change the temperature under Advanced options.

What viscosity is SAE 30 or 5W-30 motor oil?

The SAE J300 grade number sets the kinematic viscosity at 100 °C. An SAE 30 oil (and the “30” in 5W-30) is 9.3 to under 12.5 cSt at 100 °C; SAE 40 is 12.5 to under 16.3 cSt. The “W” number is a separate cold-cranking and pumping limit. The table on this page lists each grade’s range from SAE J300_202104.

Does this converter account for temperature changing the viscosity?

No. Viscosity depends strongly on temperature (water’s halves between 20 °C and about 55 °C), and this page converts a viscosity at one temperature into other units at the same temperature. The water table shows how much it changes; for an oil at another temperature you need its viscosity–temperature data (ASTM D341).

Converts a viscosity at one temperature into other units at the same temperature. Saybolt Universal seconds use the empirical ASTM D2161 equation (or its labelled linear form) from 32 SUS up, at 0–350 °F; Saybolt Furol seconds, Engler degrees, Redwood seconds and flow-cup times are not included. Viscosity does not change with temperature here, and non-Newtonian fluids (paint, ketchup, polymer melts) have no single viscosity. Water values are NIST/IAPWS data; oil grades are SAE J300 ranges, not a particular oil.

Viscosity Converter: cP to cSt, Pa·s, Stokes and Saybolt Seconds

By FindMySum · Last reviewed

A viscosity converter changes a viscosity from one unit to another. That sounds simple, but viscosity comes in two different kinds, dynamic and kinematic, and an old empirical scale, Saybolt seconds, that is not a unit at all. This converter handles all three: dynamic viscosity in Pa·s, mPa·s, centipoise, poise and two US customary units; kinematic viscosity in m²/s, mm²/s, centistokes, stokes and ft²/s; and Saybolt Universal seconds (SUS) by the ASTM D2161 equation. A density input links the dynamic and kinematic groups.

Dynamic and kinematic viscosity

Dynamic viscosity, also called absolute viscosity and written μ (mu), is the resistance of a fluid to shearing. Picture two plates with a fluid between them: dynamic viscosity is the shear stress needed to slide one plate over the other, divided by the rate of shear. Its SI unit is the pascal second (Pa·s). The older CGS unit is the poise (P), 0.1 Pa·s, and the centipoise (cP) is a hundredth of that, exactly one millipascal second.

Kinematic viscosity, written ν (nu), is dynamic viscosity divided by density:

ν = μ ÷ ρ

It tells you how quickly a fluid flows under its own weight, which is what a glass capillary viscometer measures, so it is the usual way to report oil viscosity (ASTM D445). The SI unit is m²/s; the CGS unit is the stokes (St), 10⁻⁴ m²/s, and the centistokes (cSt) is exactly one mm²/s.

The convenient result of the CGS units is the rule most people actually use:

cSt = cP ÷ density in g/cm³, and cP = cSt × density in g/cm³.

Within one group the conversions are fixed factors and need no density: 1 Pa·s = 1,000 cP = 10 P, and 1 m²/s = 1,000,000 cSt = 10,000 St. All of these are exact, as are the US customary units: one pound per foot second is 0.45359237 ÷ 0.3048 = 1.48816 Pa·s, and one pound-force second per square foot is 47.8803 Pa·s.

Worked example with the defaults

The converter opens at 100 cP to centistokes, with a density of 870 kg/m³ (0.87 g/cm³, a typical mineral oil):

  1. Dynamic viscosity: 100 cP = 0.1 Pa·s.
  2. Kinematic viscosity: 0.1 ÷ 870 = 0.000114943 m²/s, which is 114.943 cSt. With the shortcut: 100 ÷ 0.87 = 114.943.
  3. In the other units: 1.14943 St, 1 P, and, because the oil is above 1.82 cSt, 532.626 SUS at 100 °F.

Change the density and only the cross-group values move. Converting 100 cP to Pa·s or poise ignores it.

Saybolt Universal seconds

Before capillary viscometers took over, the petroleum industry measured viscosity with the Saybolt Universal viscometer: the number of seconds for 60 mL of oil to flow out through a standard orifice. The result, in Saybolt Universal seconds (SUS, also written SSU), is still found on older pump curves, hydraulic oil specifications and lubrication charts.

SUS is not a unit with a fixed factor. At low viscosities the flow time includes the time taken for the oil to accelerate and drain, so the relationship to centistokes is curved. ASTM D2161 gives an empirical equation, fitted to the original data, for kinematic viscosity ν in cSt at 100 °F:

SUS = 4.6324ν + (1.0 + 0.03264ν) ÷ [(3930.2 + 262.7ν + 23.97ν² + 1.646ν³) × 10⁻⁵]

At other temperatures between 0 and 350 °F the standard multiplies by 1 + 0.000061 × (t − 100), with t in °F, where ν is the kinematic viscosity at that same temperature. The table in the standard starts at 1.82 cSt, which is 32 SUS; nothing lower can be read on a Saybolt viscometer, so the converter shows no SUS value below that.

Above about 75 cSt the curve becomes a straight line and the standard gives a short form, SUS = 4.632 × cSt at 100 °F. Many reference tables apply that factor (or 4.635) everywhere, which is noticeably wrong for thin oils: at 10 cSt the linear form gives 46.3 SUS against the equation's 58.8. Because both forms are in use, the converter offers them as a labelled choice under Advanced options. The equation is the default, and the converter warns when the linear form is used below 75 cSt.

ASTM itself notes that the Saybolt method is obsolete in the petroleum industry and recommends reporting kinematic viscosity in mm²/s; the conversion exists to read older data. The current edition is D2161-20, reapproved in 2025.

Reference values

Water is the usual reference. At 20 °C and atmospheric pressure it has a density of 998.21 kg/m³ and a dynamic viscosity of 1.0016 mPa·s (NIST Chemistry WebBook, from the IAPWS formulation), so its kinematic viscosity is 1.0034 cSt, the same value ASTM D2161 uses as its basis. Viscosity falls quickly with temperature: at 60 °C water is about 0.47 cP. The water table on the converter page lists several temperatures and loads any of them with one click.

For engine oils, the SAE J300 grade sets a kinematic viscosity range at 100 °C. An SAE 30 oil, or the "30" in a 5W-30 multigrade, is 9.3 to under 12.5 cSt at 100 °C; an SAE 40 is 12.5 to under 16.3 cSt. The table on the page lists every grade from SAE 8 to SAE 60. A grade is a band, not a value: a particular oil's data sheet gives its measured viscosity at 40 °C and 100 °C.

Common mistakes

  • Mixing temperatures. A viscosity and a density, or a cSt and a SUS value, must be at the same temperature. Oil viscosity can change nearly tenfold between 40 °C and 100 °C.
  • Using cP and cSt as if they were the same. They only match for a fluid with a density of 1 g/cm³. For an oil at 0.87 g/cm³ the difference is 15%.
  • Treating SUS as a linear unit. Below 75 cSt use the ASTM equation, not a single factor.
  • Non-Newtonian fluids. Paints, gels, slurries and many foods have a viscosity that changes with shear rate. A single number, and so any conversion of it, only applies at the conditions it was measured under.

Related tools

Kinematic viscosity is one of the inputs to the Reynolds number calculator, which tells you whether pipe flow is laminar or turbulent. The density calculator works a density out from mass and volume, and the flow rate converter and unit converter handle the other units you meet in fluid work.

More questions

What density should I use for an oil?

Use the density at the same temperature as the viscosity, from the product data sheet if you have it. Mineral lubricating oils are typically about 0.85–0.90 g/cm³ at 15 °C and a few percent lighter when hot; the converter's 870 kg/m³ default is a typical value, not a property of any particular oil. A 3% error in density gives a 3% error in the converted viscosity.

What is SSU?

Saybolt Seconds Universal, another name for Saybolt Universal Seconds (SUS). Both mean the time in seconds for 60 mL of oil to flow through the Saybolt Universal orifice at a stated temperature. The same number is sometimes written as SUS, SSU or simply seconds Saybolt.

Why are my SUS results slightly different from another table?

Older tables were built from the original Saybolt calibration data and some round to the nearest whole second; this converter uses ASTM D2161's computer equation, which reproduces the standard's table to within about a tenth of a second. Tables that apply 4.635 or 4.632 at every viscosity also drift from the equation below about 75 cSt.

Can I convert Saybolt Furol seconds (SFS) here?

Not yet. Saybolt Furol is a larger-orifice instrument for heavy fuel oils, and ASTM D2161 gives its own equations only at 122 °F and 210 °F (50 °C and 98.9 °C). Convert SFS with that part of the standard, then enter the result here in cSt.

Is 1 cSt water viscosity exact?

Almost. ASTM D2161 bases kinematic viscosity on water being 1.0034 mm²/s at 20 °C, and NIST's water data give 1.0016 mPa·s at a density of 998.21 kg/m³, which is the same value. So water is close to, but not exactly, 1 cP and 1 cSt at room temperature.

Sources

This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.

Spotted a wrong result or a bug? Report a problem

May we count your visits with Invoker Analytics? It keeps a random visitor number in your browser. Your calculator inputs are never sent. Privacy policy