Viscosity Converter: cP to cSt, Pa·s, Stokes and Saybolt Seconds
By FindMySum · Last reviewed
A viscosity converter changes a viscosity from one unit to another. That sounds simple, but viscosity comes in two different kinds, dynamic and kinematic, and an old empirical scale, Saybolt seconds, that is not a unit at all. This converter handles all three: dynamic viscosity in Pa·s, mPa·s, centipoise, poise and two US customary units; kinematic viscosity in m²/s, mm²/s, centistokes, stokes and ft²/s; and Saybolt Universal seconds (SUS) by the ASTM D2161 equation. A density input links the dynamic and kinematic groups.
Dynamic and kinematic viscosity
Dynamic viscosity, also called absolute viscosity and written μ (mu), is the resistance of a fluid to shearing. Picture two plates with a fluid between them: dynamic viscosity is the shear stress needed to slide one plate over the other, divided by the rate of shear. Its SI unit is the pascal second (Pa·s). The older CGS unit is the poise (P), 0.1 Pa·s, and the centipoise (cP) is a hundredth of that, exactly one millipascal second.
Kinematic viscosity, written ν (nu), is dynamic viscosity divided by density:
ν = μ ÷ ρ
It tells you how quickly a fluid flows under its own weight, which is what a glass capillary viscometer measures, so it is the usual way to report oil viscosity (ASTM D445). The SI unit is m²/s; the CGS unit is the stokes (St), 10⁻⁴ m²/s, and the centistokes (cSt) is exactly one mm²/s.
The convenient result of the CGS units is the rule most people actually use:
cSt = cP ÷ density in g/cm³, and cP = cSt × density in g/cm³.
Within one group the conversions are fixed factors and need no density: 1 Pa·s = 1,000 cP = 10 P, and 1 m²/s = 1,000,000 cSt = 10,000 St. All of these are exact, as are the US customary units: one pound per foot second is 0.45359237 ÷ 0.3048 = 1.48816 Pa·s, and one pound-force second per square foot is 47.8803 Pa·s.
Worked example with the defaults
The converter opens at 100 cP to centistokes, with a density of 870 kg/m³ (0.87 g/cm³, a typical mineral oil):
- Dynamic viscosity: 100 cP = 0.1 Pa·s.
- Kinematic viscosity: 0.1 ÷ 870 = 0.000114943 m²/s, which is 114.943 cSt. With the shortcut: 100 ÷ 0.87 = 114.943.
- In the other units: 1.14943 St, 1 P, and, because the oil is above 1.82 cSt, 532.626 SUS at 100 °F.
Change the density and only the cross-group values move. Converting 100 cP to Pa·s or poise ignores it.
Saybolt Universal seconds
Before capillary viscometers took over, the petroleum industry measured viscosity with the Saybolt Universal viscometer: the number of seconds for 60 mL of oil to flow out through a standard orifice. The result, in Saybolt Universal seconds (SUS, also written SSU), is still found on older pump curves, hydraulic oil specifications and lubrication charts.
SUS is not a unit with a fixed factor. At low viscosities the flow time includes the time taken for the oil to accelerate and drain, so the relationship to centistokes is curved. ASTM D2161 gives an empirical equation, fitted to the original data, for kinematic viscosity ν in cSt at 100 °F:
SUS = 4.6324ν + (1.0 + 0.03264ν) ÷ [(3930.2 + 262.7ν + 23.97ν² + 1.646ν³) × 10⁻⁵]
At other temperatures between 0 and 350 °F the standard multiplies by 1 + 0.000061 × (t − 100), with t in °F, where ν is the kinematic viscosity at that same temperature. The table in the standard starts at 1.82 cSt, which is 32 SUS; nothing lower can be read on a Saybolt viscometer, so the converter shows no SUS value below that.
Above about 75 cSt the curve becomes a straight line and the standard gives a short form, SUS = 4.632 × cSt at 100 °F. Many reference tables apply that factor (or 4.635) everywhere, which is noticeably wrong for thin oils: at 10 cSt the linear form gives 46.3 SUS against the equation's 58.8. Because both forms are in use, the converter offers them as a labelled choice under Advanced options. The equation is the default, and the converter warns when the linear form is used below 75 cSt.
ASTM itself notes that the Saybolt method is obsolete in the petroleum industry and recommends reporting kinematic viscosity in mm²/s; the conversion exists to read older data. The current edition is D2161-20, reapproved in 2025.
Reference values
Water is the usual reference. At 20 °C and atmospheric pressure it has a density of 998.21 kg/m³ and a dynamic viscosity of 1.0016 mPa·s (NIST Chemistry WebBook, from the IAPWS formulation), so its kinematic viscosity is 1.0034 cSt, the same value ASTM D2161 uses as its basis. Viscosity falls quickly with temperature: at 60 °C water is about 0.47 cP. The water table on the converter page lists several temperatures and loads any of them with one click.
For engine oils, the SAE J300 grade sets a kinematic viscosity range at 100 °C. An SAE 30 oil, or the "30" in a 5W-30 multigrade, is 9.3 to under 12.5 cSt at 100 °C; an SAE 40 is 12.5 to under 16.3 cSt. The table on the page lists every grade from SAE 8 to SAE 60. A grade is a band, not a value: a particular oil's data sheet gives its measured viscosity at 40 °C and 100 °C.
Common mistakes
- Mixing temperatures. A viscosity and a density, or a cSt and a SUS value, must be at the same temperature. Oil viscosity can change nearly tenfold between 40 °C and 100 °C.
- Using cP and cSt as if they were the same. They only match for a fluid with a density of 1 g/cm³. For an oil at 0.87 g/cm³ the difference is 15%.
- Treating SUS as a linear unit. Below 75 cSt use the ASTM equation, not a single factor.
- Non-Newtonian fluids. Paints, gels, slurries and many foods have a viscosity that changes with shear rate. A single number, and so any conversion of it, only applies at the conditions it was measured under.
Related tools
Kinematic viscosity is one of the inputs to the Reynolds number calculator, which tells you whether pipe flow is laminar or turbulent. The density calculator works a density out from mass and volume, and the flow rate converter and unit converter handle the other units you meet in fluid work.
More questions
What density should I use for an oil?
Use the density at the same temperature as the viscosity, from the product data sheet if you have it. Mineral lubricating oils are typically about 0.85–0.90 g/cm³ at 15 °C and a few percent lighter when hot; the converter's 870 kg/m³ default is a typical value, not a property of any particular oil. A 3% error in density gives a 3% error in the converted viscosity.
What is SSU?
Saybolt Seconds Universal, another name for Saybolt Universal Seconds (SUS). Both mean the time in seconds for 60 mL of oil to flow through the Saybolt Universal orifice at a stated temperature. The same number is sometimes written as SUS, SSU or simply seconds Saybolt.
Why are my SUS results slightly different from another table?
Older tables were built from the original Saybolt calibration data and some round to the nearest whole second; this converter uses ASTM D2161's computer equation, which reproduces the standard's table to within about a tenth of a second. Tables that apply 4.635 or 4.632 at every viscosity also drift from the equation below about 75 cSt.
Can I convert Saybolt Furol seconds (SFS) here?
Not yet. Saybolt Furol is a larger-orifice instrument for heavy fuel oils, and ASTM D2161 gives its own equations only at 122 °F and 210 °F (50 °C and 98.9 °C). Convert SFS with that part of the standard, then enter the result here in cSt.
Is 1 cSt water viscosity exact?
Almost. ASTM D2161 bases kinematic viscosity on water being 1.0034 mm²/s at 20 °C, and NIST's water data give 1.0016 mPa·s at a density of 998.21 kg/m³, which is the same value. So water is close to, but not exactly, 1 cP and 1 cSt at room temperature.
Sources
- ASTM D2161-20 (reapproved 2025), Standard Practice for Conversion of Kinematic Viscosity to Saybolt Universal Viscosity or to Saybolt Furol Viscosity
- NIST Special Publication 811 (2008), Guide for the Use of the International System of Units, Appendix B.8 (viscosity, dynamic and kinematic)
- NIST Chemistry WebBook, SRD 69, Thermophysical Properties of Fluid Systems (water, IAPWS-95 and IAPWS 2008 viscosity)
- SAE J300 Engine Oil Viscosity Classification (J300_202104)
This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.