Reynolds Number Calculator with Water Viscosity by Temperature
By FindMySum · Last reviewed
The Reynolds number is the first thing to work out in almost any fluid flow problem, because it tells you which kind of flow you have. This Reynolds number calculator finds it for a round pipe, a rectangular duct or a flat plate, from a velocity or a volume flow rate, with the properties of water or air at your temperature built in, and it shows the full table of water viscosity from 0 °C to 100 °C.
The formula
Re = ρ × v × L ÷ μ = v × L ÷ ν
- ρ is the density (kg/m³) and μ the dynamic viscosity (Pa·s).
- ν = μ ÷ ρ is the kinematic viscosity (m²/s).
- v is the average velocity (m/s).
- L is the characteristic length: the inside diameter of a pipe, the hydraulic diameter of a duct, or the distance along a plate.
Re has no units. It compares the inertia of the moving fluid, which tends to make eddies, with its viscosity, which damps them.
Laminar, transitional and turbulent
For flow in a full round pipe, the usual textbook bounds are:
| Reynolds number | Flow |
|---|---|
| Below 2,300 | Laminar: smooth layers, no mixing across the pipe |
| 2,300 to 4,000 | Transitional: can flip between the two |
| Above 4,000 | Turbulent: eddies and rapid mixing |
These limits are conventions. In very smooth, vibration-free pipes laminar flow has been kept above 10,000, while a sharp inlet or a pump can trigger turbulence lower down. For a boundary layer on a flat plate, transition usually happens near Re_x = 500,000.
Worked example: the default
Water at 20 °C flowing at 1 m/s through a pipe with a 50 mm bore. From the NIST tables, ρ = 998.21 kg/m³ and μ = 1.0016 mPa·s:
Re = 998.21 × 1 × 0.05 ÷ 0.0010016 ≈ 49,800
That is well into the turbulent range, as almost all water and air flows in buildings are. You would need to slow the water to about 5 cm/s for the flow to become laminar in that pipe.
From a flow rate
If you know the flow rate Q instead of the velocity, the average velocity is Q divided by the cross-section area: v = Q ÷ (πD²/4) for a round pipe. For example, 0.5 L/s through a 25 mm bore is about 1.02 m/s. The calculator does this when you choose "Flow rate", in L/s, L/min, m³/h or US gallons per minute.
Ducts and hydraulic diameter
Rectangular ducts use the hydraulic diameter, D_h = 4A ÷ P, four times the cross-section area divided by the wetted perimeter. For a duct w wide and h high, D_h = 2wh ÷ (w + h). A 300 × 200 mm duct has D_h = 240 mm, so air at 20 °C moving at 5 m/s gives Re ≈ 80,000. Using D_h lets the round-pipe limits and friction charts be used for other shapes, with some loss of accuracy for very flat ones.
Viscosity of water by temperature
Water's viscosity falls steeply as it warms, from about 1.79 mPa·s at 0 °C to 1.00 at 20 °C and 0.28 at 100 °C. Its density barely changes, so the kinematic viscosity follows the same trend. The table on the page lists both from the NIST Chemistry WebBook, which implements the international IAPWS formulations: IAPWS-95 for density and IAPWS 2008 for viscosity. Values between the 5 °C rows are interpolated, within about 0.15%.
That temperature effect is large in practice. The same hot-water pipe at 60 °C has a Reynolds number about 2.1 times higher than with 20 °C water at the same velocity.
Viscosity of air
Gases behave the other way: their viscosity rises with temperature. For air, the calculator uses Sutherland's law as given in the US Standard Atmosphere 1976, μ = 1.458 × 10⁻⁶ × T^1.5 ÷ (T + 110.4), with T in kelvin. At 20 °C that is about 1.81 × 10⁻⁵ Pa·s. Air's density comes from the ideal gas law at the pressure you set in the advanced options; at altitude, lower pressure lowers the density and the Reynolds number.
Other fluids
For oils, glycol mixes, fuels or slurries, choose "Type density and viscosity" and enter values at your operating temperature from a data sheet. Viscosity in centipoise is the same number as mPa·s. Remember that oil viscosity changes even faster with temperature than water's, so a cold start can be laminar and the same system turbulent once warm.
Limits
The Reynolds number describes the type of flow but not the pressure drop: for that, you also need the pipe roughness and length. The flow is assumed to be fully developed (well away from inlets and fittings) and the fluid Newtonian, meaning its viscosity doesn't change with shear rate, which is true for water, air and most oils but not for paints, blood or slurries.
To find a flow rate from a velocity and pipe size, try the flow rate calculator, and for the pressure a column of fluid produces, see the pressure calculator.
More questions
Who was Reynolds?
Osborne Reynolds, a British engineer, showed in 1883 that dye injected into water flowing through a glass tube stayed in a neat thread at low speeds and broke up into eddies at higher ones, and that the switch depended on a single combination of speed, tube size and viscosity. That combination now carries his name.
Is a higher Reynolds number bad?
Not in itself. Turbulent flow mixes and transfers heat far better than laminar flow, which is why heat exchangers are designed for it. The cost is higher friction: pressure drop in turbulent pipe flow rises roughly with the square of velocity, against linearly for laminar flow.
What Reynolds numbers do blood and honey reach?
Low ones. Blood in the aorta reaches a few thousand at peak flow, but in small arteries and capillaries it is far below 1, firmly laminar. Honey pouring off a spoon is so viscous its Reynolds number is well under 1, which is why it folds and coils instead of splashing.
Does pipe roughness change the Reynolds number?
No. Re depends only on the fluid, the velocity and the diameter. Roughness matters afterwards, in turbulent flow, where it raises the friction factor and the pressure drop. The friction loss calculator uses both.
How is viscosity measured?
With a viscometer. Capillary viscometers time how long a liquid takes to drain through a narrow tube, rotational viscometers measure the torque to spin a spindle in it, and falling-ball viscometers time a ball sinking through it. The water values here come from IAPWS's fit to many such measurements.
Sources
This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.