Skip to content

Reynolds Number Calculator

Find the Reynolds number for water, air or any fluid in a pipe, duct or along a plate, from velocity or flow rate, with water viscosity by temperature (IAPWS).

Calculator Details

Reynolds number:49,831See results ↓

Full round pipe, rectangular duct, or along a flat plate

Water and air use properties at the temperature you enter

Water 0–100 °C (32–212 °F); air −100 to 500 °C

Unit for the diameter, duct sides or distance

Bore of the pipe, not the nominal size

Average velocity, or the volume flow rate through the pipe or duct

Mean flow speed (water in house pipes is typically 1–2.5 m/s)

Your Results

Reynolds number: 49,831

Reynolds number

49,831

Flow regime

Turbulent

Laminar < 2,300, turbulent > 4,000

Average velocity

1 m/s

Length used 0.05 m

Viscosity

1.002 mPa·s

Kinematic 1.003 mm²/s (cSt); density 998.21 kg/m³

Water at 1 m/s in the pipe has a Reynolds number of 49,831: the flow is turbulent.

Compare scenarios

Save these inputs as a scenario, change them, and compare the results side by side.

Loading, available in a moment

Reynolds number by velocity

Reynolds number by velocity

Detailed Breakdown

Viscosity of water at 1 atm, 0–100 °C
Temperature (°C)Density (kg/m³)Dynamic (mPa·s)Kinematic (mm²/s)
0.01999.841.7911.791
5999.971.5181.518
10999.71.3061.306
15999.11.1381.139
20 (nearest yours)998.211.0021.003
25997.050.890.8927
30995.650.79720.8007
35994.030.71910.7235
40992.220.65270.6579
45990.210.59580.6017
50988.040.54650.5531
55985.690.50360.5109
60983.20.4660.474
65980.550.43290.4415
70977.760.40360.4127
75974.840.37740.3872
80971.790.35410.3643
85968.610.33310.3439
90965.310.31420.3255
95961.890.29710.3089
99.974958.370.28170.2939

NIST Chemistry WebBook (IAPWS-95 density, IAPWS 2008 viscosity). 0.01 °C is the triple point and 99.974 °C the boiling point at 1 atm. 1 mPa·s = 1 centipoise; 1 mm²/s = 1 centistokes.

How This Calculator Works

How It’s Calculated

Re = ρ × v × D ÷ μ = v × D ÷ ν

Your calculation: 998.21 kg/m³ × 1 m/s × 0.05 m ÷ 0.001002 Pa·s = 49,831, so the flow is turbulent. Water properties are at 20 °C, interpolated in the NIST table below.

Frequently Asked Questions

What is the Reynolds number?

A dimensionless number, Re = ρvL ÷ μ, that compares a fluid’s inertia (density × velocity × size) with its viscosity. Low values mean smooth, layered laminar flow; high values mean chaotic, mixing turbulent flow. It lets engineers compare flows of different fluids, sizes and speeds.

When is pipe flow laminar or turbulent?

By the usual textbook bounds, flow in a round pipe is laminar below Re ≈ 2,300, turbulent above about 4,000, and can switch either way in between. Water at 1 m/s in a 50 mm pipe has Re ≈ 49,831, firmly turbulent, as almost all plumbing and HVAC flow is.

What is the viscosity of water?

About 1.002 mPa·s (centipoise) at 20 °C, according to the IAPWS 2008 formulation. It falls steeply with temperature: 1.791 mPa·s near 0 °C and 0.354 mPa·s at 80 °C. The full 0–100 °C table is on this page.

What is the difference between dynamic and kinematic viscosity?

Dynamic viscosity μ (Pa·s or centipoise) is a fluid’s resistance to shearing. Kinematic viscosity ν = μ ÷ ρ (m²/s or centistokes) divides out the density, and Re = vL ÷ ν. Water at 20 °C has ν ≈ 1.003 mm²/s; air at 20 °C about 15.1 mm²/s, fifteen times more despite its far lower μ.

What is hydraulic diameter?

For a duct that isn’t round, D_h = 4 × area ÷ wetted perimeter, which makes the Reynolds number and friction charts for round pipes usable. A 300 × 200 mm duct has D_h = 240 mm; at 5 m/s of 20 °C air that gives Re ≈ 79,680.

Why does temperature matter so much?

Liquid viscosity drops fast as it warms (water’s falls by more than half between 10 °C and 60 °C), so the same pipe and velocity give a much higher Reynolds number with hot water. Gases do the opposite: their viscosity rises with temperature.

What Reynolds number does a flat plate turn turbulent at?

The boundary layer along a smooth flat plate typically becomes turbulent around Re_x ≈ 5 × 10⁵, where x is the distance from the leading edge. Rough surfaces or a disturbed oncoming flow trip it much earlier.

Water properties are the NIST Chemistry WebBook values at 1 atm (IAPWS-95 and IAPWS 2008), interpolated between 5 °C rows (within about 0.15%); air uses the US Standard Atmosphere 1976 Sutherland law and the ideal-gas density for dry air. The laminar and turbulent limits (2,300 and 4,000 for pipes, about 5 × 10⁵ for a flat plate) are common textbook bounds: real transition depends on inlet shape, roughness and vibration. Oils, glycol mixes and other fluids aren’t built in yet; type their density and viscosity at your temperature from the supplier’s data sheet.

Reynolds Number Calculator with Water Viscosity by Temperature

By FindMySum · Last reviewed

The Reynolds number is the first thing to work out in almost any fluid flow problem, because it tells you which kind of flow you have. This Reynolds number calculator finds it for a round pipe, a rectangular duct or a flat plate, from a velocity or a volume flow rate, with the properties of water or air at your temperature built in, and it shows the full table of water viscosity from 0 °C to 100 °C.

The formula

Re = ρ × v × L ÷ μ = v × L ÷ ν

  • ρ is the density (kg/m³) and μ the dynamic viscosity (Pa·s).
  • ν = μ ÷ ρ is the kinematic viscosity (m²/s).
  • v is the average velocity (m/s).
  • L is the characteristic length: the inside diameter of a pipe, the hydraulic diameter of a duct, or the distance along a plate.

Re has no units. It compares the inertia of the moving fluid, which tends to make eddies, with its viscosity, which damps them.

Laminar, transitional and turbulent

For flow in a full round pipe, the usual textbook bounds are:

Reynolds numberFlow
Below 2,300Laminar: smooth layers, no mixing across the pipe
2,300 to 4,000Transitional: can flip between the two
Above 4,000Turbulent: eddies and rapid mixing

These limits are conventions. In very smooth, vibration-free pipes laminar flow has been kept above 10,000, while a sharp inlet or a pump can trigger turbulence lower down. For a boundary layer on a flat plate, transition usually happens near Re_x = 500,000.

Worked example: the default

Water at 20 °C flowing at 1 m/s through a pipe with a 50 mm bore. From the NIST tables, ρ = 998.21 kg/m³ and μ = 1.0016 mPa·s:

Re = 998.21 × 1 × 0.05 ÷ 0.0010016 ≈ 49,800

That is well into the turbulent range, as almost all water and air flows in buildings are. You would need to slow the water to about 5 cm/s for the flow to become laminar in that pipe.

From a flow rate

If you know the flow rate Q instead of the velocity, the average velocity is Q divided by the cross-section area: v = Q ÷ (πD²/4) for a round pipe. For example, 0.5 L/s through a 25 mm bore is about 1.02 m/s. The calculator does this when you choose "Flow rate", in L/s, L/min, m³/h or US gallons per minute.

Ducts and hydraulic diameter

Rectangular ducts use the hydraulic diameter, D_h = 4A ÷ P, four times the cross-section area divided by the wetted perimeter. For a duct w wide and h high, D_h = 2wh ÷ (w + h). A 300 × 200 mm duct has D_h = 240 mm, so air at 20 °C moving at 5 m/s gives Re ≈ 80,000. Using D_h lets the round-pipe limits and friction charts be used for other shapes, with some loss of accuracy for very flat ones.

Viscosity of water by temperature

Water's viscosity falls steeply as it warms, from about 1.79 mPa·s at 0 °C to 1.00 at 20 °C and 0.28 at 100 °C. Its density barely changes, so the kinematic viscosity follows the same trend. The table on the page lists both from the NIST Chemistry WebBook, which implements the international IAPWS formulations: IAPWS-95 for density and IAPWS 2008 for viscosity. Values between the 5 °C rows are interpolated, within about 0.15%.

That temperature effect is large in practice. The same hot-water pipe at 60 °C has a Reynolds number about 2.1 times higher than with 20 °C water at the same velocity.

Viscosity of air

Gases behave the other way: their viscosity rises with temperature. For air, the calculator uses Sutherland's law as given in the US Standard Atmosphere 1976, μ = 1.458 × 10⁻⁶ × T^1.5 ÷ (T + 110.4), with T in kelvin. At 20 °C that is about 1.81 × 10⁻⁵ Pa·s. Air's density comes from the ideal gas law at the pressure you set in the advanced options; at altitude, lower pressure lowers the density and the Reynolds number.

Other fluids

For oils, glycol mixes, fuels or slurries, choose "Type density and viscosity" and enter values at your operating temperature from a data sheet. Viscosity in centipoise is the same number as mPa·s. Remember that oil viscosity changes even faster with temperature than water's, so a cold start can be laminar and the same system turbulent once warm.

Limits

The Reynolds number describes the type of flow but not the pressure drop: for that, you also need the pipe roughness and length. The flow is assumed to be fully developed (well away from inlets and fittings) and the fluid Newtonian, meaning its viscosity doesn't change with shear rate, which is true for water, air and most oils but not for paints, blood or slurries.

To find a flow rate from a velocity and pipe size, try the flow rate calculator, and for the pressure a column of fluid produces, see the pressure calculator.

More questions

Who was Reynolds?

Osborne Reynolds, a British engineer, showed in 1883 that dye injected into water flowing through a glass tube stayed in a neat thread at low speeds and broke up into eddies at higher ones, and that the switch depended on a single combination of speed, tube size and viscosity. That combination now carries his name.

Is a higher Reynolds number bad?

Not in itself. Turbulent flow mixes and transfers heat far better than laminar flow, which is why heat exchangers are designed for it. The cost is higher friction: pressure drop in turbulent pipe flow rises roughly with the square of velocity, against linearly for laminar flow.

What Reynolds numbers do blood and honey reach?

Low ones. Blood in the aorta reaches a few thousand at peak flow, but in small arteries and capillaries it is far below 1, firmly laminar. Honey pouring off a spoon is so viscous its Reynolds number is well under 1, which is why it folds and coils instead of splashing.

Does pipe roughness change the Reynolds number?

No. Re depends only on the fluid, the velocity and the diameter. Roughness matters afterwards, in turbulent flow, where it raises the friction factor and the pressure drop. The friction loss calculator uses both.

How is viscosity measured?

With a viscometer. Capillary viscometers time how long a liquid takes to drain through a narrow tube, rotational viscometers measure the torque to spin a spindle in it, and falling-ball viscometers time a ball sinking through it. The water values here come from IAPWS's fit to many such measurements.

Sources

This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.

Spotted a wrong result or a bug? Report a problem

May we count your visits with Invoker Analytics? It keeps a random visitor number in your browser. Your calculator inputs are never sent. Privacy policy