Efficiency Calculator: Output ÷ Input, Stages and Cost of Losses
By FindMySum · Last reviewed
Every machine turns some of the energy it receives into something useful and loses the rest, usually as heat. Efficiency is the useful share. This efficiency calculator works it out from input and output, finds the input needed for an output you require, combines several stages into one overall efficiency, and puts a price on the losses. It also explains the ratings you meet on Canadian furnaces and heat pumps.
The formula
η = useful output ÷ input × 100%
Input and output must be in the same unit: energy (kWh, J, MJ, GJ, BTU) or power (W, kW, horsepower, BTU/h). The difference, input − output, is the loss. Rearranged, the input needed for a required output is:
input = output ÷ η
Worked example: the default
The calculator opens with 1,000 kWh in and 850 kWh of useful output.
- Efficiency: 850 ÷ 1,000 = 0.85, or 85%
- Losses: 1,000 − 850 = 150 kWh (15% of the input)
- At $0.12/kWh, the input costs $120.00 and the losses $18.00
Improving the device to 90% at the same output would cut the input to 944 kWh and the losses to 94 kWh, saving about $6.70 for the same useful work.
Stages in series
When energy passes through several conversions, each stage only passes on its share of what it receives, so the efficiencies multiply:
η_total = η₁ × η₂ × η₃ × …
A power plant generator at 95%, transmission and distribution at 92%, and a motor at 88% give 0.95 × 0.92 × 0.88 = 76.9% from the generator shaft to the motor shaft. Of 1,000 units in, 950 leave the generator, 874 reach the motor and 769 do useful work. The chart shows each stage's useful and lost energy side by side. Enter up to eight stages as percentages separated by commas.
Furnaces and AFUE
Furnaces are rated by annual fuel utilization efficiency (AFUE), measured under ANSI/ASHRAE Standard 103 over a typical heating season, including start-up, cycling and standby losses. Under Canada's Energy Efficiency Regulations, 2016, gas furnaces with an input of up to 65.92 kW (225,000 BTU/h) made on or after 3 July 2019 must have an AFUE of at least 95%. Choose "New gas furnace in Canada" under "Compare with" and the calculator says whether your figure meets that minimum.
For a 100,000 BTU/h furnace at 95%, 95,000 BTU/h reaches the house and 5,000 BTU/h goes up the vent. An older 80% furnace loses 20,000 BTU/h, four times as much, for the same gas.
Heat pumps and COP above 100%
If the output is larger than the input, the calculator reports a coefficient of performance (COP) instead of calling it more than 100% efficient. A heat pump uses electricity to move heat from the outdoor air or the ground into the house, so it can deliver 3 kWh of heat for 1 kWh of electricity: COP 3. No energy is created; the extra 2 kWh came from outside. COP falls as the outdoor temperature drops, which is why cold-climate heat pumps publish ratings at several temperatures.
Power and running time
When the unit is a power (W, kW, hp, BTU/h), costs need a running time. A 10 kW motor delivering 9 kW wastes 1 kW; over 1,000 hours that is 1,000 kWh, or $100 at $0.10/kWh. Natural gas in much of Canada is priced per gigajoule, so choose "per GJ" for gas appliances.
Limits
The calculation uses one efficiency and one price. Real devices are less efficient at part load, heat pumps vary with temperature, and bills add delivery charges, demand charges and taxes. Use measured or rated figures for your equipment where you can.
More questions
Why can no engine be 100% efficient?
The second law of thermodynamics limits any engine that turns heat into work. Even an ideal Carnot engine working between a hot source at T_h and a cold sink at T_c (in kelvin) can convert at most 1 − T_c/T_h of the heat. A power plant with steam at 800 K rejecting heat at 300 K is capped at 62.5%, before any friction or heat leaks.
Is an electric baseboard heater 100% efficient?
At the point of use, essentially yes: every watt of electricity becomes heat in the room. That doesn't make it cheap. A heat pump can deliver two to four units of heat per unit of electricity, and in regions where electricity is generated by burning fuel, much of the original fuel energy was lost at the power plant.
What is the difference between efficiency and efficacy?
Efficiency compares like with like, such as joules out per joule in, so it is a pure number. Efficacy compares different quantities, such as lumens of light per watt of electricity. Lighting is rated by efficacy because the eye's response, not raw energy, decides how bright a lamp looks.
What is a condensing furnace?
A gas furnace with a second heat exchanger that cools the exhaust enough for its water vapour to condense, recovering the latent heat that older furnaces sent up the chimney. That pushes the AFUE from around 80% to 95% or more. The cooler exhaust can vent through plastic pipe in a side wall, and the condensate is drained.
Do losses always count as waste?
Not always. The heat lost by a fridge compressor, a computer or a lighting ballast ends up in the room, which helps in a Canadian winter and adds to the cooling load in summer. Combined heat and power plants capture a power station's waste heat for district heating, raising the useful share of the fuel well above the electrical efficiency alone.
Sources
This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.