Calculate efficiency from input and output energy or power, the input a job needs, chained stages, and the cost of the losses; furnace AFUE and heat-pump COP explained.

Calculator Details

Efficiency:85%See results ↓

Efficiency from input and output, the input a job needs, or the overall efficiency of several stages

Energy (kWh, J, BTU…) or power (W, kW, hp, BTU/h); input and output use the same unit

What you supply: fuel, electricity, work

What you get: heat delivered, work done, light

Leave 0 to skip costs

Electricity is usually per kWh; natural gas per GJ in much of Canada

A regulatory minimum

Your Results

Efficiency: 85%

Efficiency

85%

0.85 as a fraction

Input

1,000 kWh

Useful output

850 kWh

Losses

150 kWh

15% of the input

Cost of the input

$120.00

1,000 kWh

Cost of the losses

$18.00

Efficiency is 85%: 850 kWh out of 1,000 kWh in, with 150 kWh lost. The losses cost $18.00.

Compare scenarios

Save these inputs as a scenario, change them, and compare the results side by side.

Loading, available in a moment

Where the energy goes, stage by stage

Where the energy goes, stage by stage

Detailed Breakdown

Energy balance
StageEfficiencyInOutLost
Device85%1,000 kWh850 kWh150 kWh

How This Calculator Works

How It’s Calculated

η = useful output ÷ input × 100% · input = output ÷ η · η_total = η₁ × η₂ × …
cost of losses = (input − output) × price

Your calculation: 850 ÷ 1,000 = 0.85, or 85%. The losses (150 kWh) cost $18.00.

Frequently Asked Questions

How do I calculate efficiency?

Divide the useful output by the input and multiply by 100: η = output ÷ input × 100%. A device that delivers 850 kWh of useful energy from 1,000 kWh is 85% efficient; the other 150 kWh is lost, mostly as heat. Input and output must be in the same unit.

How do I find the input needed for a given output?

Divide the output by the efficiency: input = output ÷ η. A 500 W load supplied through an 80% efficient power supply draws 625 W from the wall, and 125 W becomes heat in the supply.

How do I combine the efficiencies of several stages?

Multiply them, because each stage only passes on its share of what it receives. A 95% generator, 92% transmission and 88% motor give 0.95 × 0.92 × 0.88 = 76.91% overall. The overall efficiency is always lower than the worst single stage.

What does AFUE mean for a furnace?

Annual fuel utilization efficiency: the share of the fuel's heat that reaches your home over a typical heating season, including start-up and standby losses (ANSI/ASHRAE 103). In Canada, new gas furnaces must have an AFUE of at least 95% under the Energy Efficiency Regulations, 2016, which in practice means a condensing furnace.

Can efficiency be more than 100%?

Not for converting energy from one form to another: that would create energy. A heat pump can deliver 2 to 4 times as much heat as the electricity it uses because it moves heat from outdoors rather than making it, so its rating is a coefficient of performance (COP), not an efficiency. The calculator shows a ratio above 1 as a COP.

How much do losses cost?

Multiply the lost energy by its price. At $0.12/kWh, losing 150 kWh costs $18.00. For a device rated in power (W, kW, hp), enter the running hours: a 1 kW loss for 1000 hours is 1000 kWh. Natural gas is often priced per gigajoule in Canada, so you can enter a $/GJ price instead.

How efficient are common devices?

Typical figures: large electric motors 90% to 97%, transformers above 98%, car petrol engines about 25% to 40% at their best, power plants burning fuel 33% to 60%. LED lamps give roughly 5 to 10 times as much light per watt as incandescent bulbs, which turn only about 2% to 5% of their electricity into visible light. Check the nameplate or datasheet for your device.

Efficiency is useful output ÷ input for energy or power (OpenStax University Physics Vol. 1 §7.4, Vol. 2 §4.3–4.5); stages in series multiply. Ratios above 100% are shown as a coefficient of performance. The furnace minimum is NRCan’s 95% AFUE for new gas furnaces under the Energy Efficiency Regulations, 2016 (from 3 July 2019). Costs use the single price you enter. It leaves out part-load and seasonal variation (other than what AFUE already includes), efficiency that changes with temperature (heat pumps lose COP as it gets colder), time-of-use and demand charges, taxes and delivery fees, and the energy that losses may usefully supply, such as waste heat warming a building.

Efficiency Calculator: Output ÷ Input, Stages and Cost of Losses

By FindMySum · Last reviewed

Every machine turns some of the energy it receives into something useful and loses the rest, usually as heat. Efficiency is the useful share. This efficiency calculator works it out from input and output, finds the input needed for an output you require, combines several stages into one overall efficiency, and puts a price on the losses. It also explains the ratings you meet on Canadian furnaces and heat pumps.

The formula

η = useful output ÷ input × 100%

Input and output must be in the same unit: energy (kWh, J, MJ, GJ, BTU) or power (W, kW, horsepower, BTU/h). The difference, input − output, is the loss. Rearranged, the input needed for a required output is:

input = output ÷ η

Worked example: the default

The calculator opens with 1,000 kWh in and 850 kWh of useful output.

  • Efficiency: 850 ÷ 1,000 = 0.85, or 85%
  • Losses: 1,000 − 850 = 150 kWh (15% of the input)
  • At $0.12/kWh, the input costs $120.00 and the losses $18.00

Improving the device to 90% at the same output would cut the input to 944 kWh and the losses to 94 kWh, saving about $6.70 for the same useful work.

Stages in series

When energy passes through several conversions, each stage only passes on its share of what it receives, so the efficiencies multiply:

η_total = η₁ × η₂ × η₃ × …

A power plant generator at 95%, transmission and distribution at 92%, and a motor at 88% give 0.95 × 0.92 × 0.88 = 76.9% from the generator shaft to the motor shaft. Of 1,000 units in, 950 leave the generator, 874 reach the motor and 769 do useful work. The chart shows each stage's useful and lost energy side by side. Enter up to eight stages as percentages separated by commas.

Furnaces and AFUE

Furnaces are rated by annual fuel utilization efficiency (AFUE), measured under ANSI/ASHRAE Standard 103 over a typical heating season, including start-up, cycling and standby losses. Under Canada's Energy Efficiency Regulations, 2016, gas furnaces with an input of up to 65.92 kW (225,000 BTU/h) made on or after 3 July 2019 must have an AFUE of at least 95%. Choose "New gas furnace in Canada" under "Compare with" and the calculator says whether your figure meets that minimum.

For a 100,000 BTU/h furnace at 95%, 95,000 BTU/h reaches the house and 5,000 BTU/h goes up the vent. An older 80% furnace loses 20,000 BTU/h, four times as much, for the same gas.

Heat pumps and COP above 100%

If the output is larger than the input, the calculator reports a coefficient of performance (COP) instead of calling it more than 100% efficient. A heat pump uses electricity to move heat from the outdoor air or the ground into the house, so it can deliver 3 kWh of heat for 1 kWh of electricity: COP 3. No energy is created; the extra 2 kWh came from outside. COP falls as the outdoor temperature drops, which is why cold-climate heat pumps publish ratings at several temperatures.

Power and running time

When the unit is a power (W, kW, hp, BTU/h), costs need a running time. A 10 kW motor delivering 9 kW wastes 1 kW; over 1,000 hours that is 1,000 kWh, or $100 at $0.10/kWh. Natural gas in much of Canada is priced per gigajoule, so choose "per GJ" for gas appliances.

Limits

The calculation uses one efficiency and one price. Real devices are less efficient at part load, heat pumps vary with temperature, and bills add delivery charges, demand charges and taxes. Use measured or rated figures for your equipment where you can.

More questions

Why can no engine be 100% efficient?

The second law of thermodynamics limits any engine that turns heat into work. Even an ideal Carnot engine working between a hot source at T_h and a cold sink at T_c (in kelvin) can convert at most 1 − T_c/T_h of the heat. A power plant with steam at 800 K rejecting heat at 300 K is capped at 62.5%, before any friction or heat leaks.

Is an electric baseboard heater 100% efficient?

At the point of use, essentially yes: every watt of electricity becomes heat in the room. That doesn't make it cheap. A heat pump can deliver two to four units of heat per unit of electricity, and in regions where electricity is generated by burning fuel, much of the original fuel energy was lost at the power plant.

What is the difference between efficiency and efficacy?

Efficiency compares like with like, such as joules out per joule in, so it is a pure number. Efficacy compares different quantities, such as lumens of light per watt of electricity. Lighting is rated by efficacy because the eye's response, not raw energy, decides how bright a lamp looks.

What is a condensing furnace?

A gas furnace with a second heat exchanger that cools the exhaust enough for its water vapour to condense, recovering the latent heat that older furnaces sent up the chimney. That pushes the AFUE from around 80% to 95% or more. The cooler exhaust can vent through plastic pipe in a side wall, and the condensate is drained.

Do losses always count as waste?

Not always. The heat lost by a fridge compressor, a computer or a lighting ballast ends up in the room, which helps in a Canadian winter and adds to the cooling load in summer. Combined heat and power plants capture a power station's waste heat for district heating, raising the useful share of the fuel well above the electrical efficiency alone.

Sources

This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.