Skip to content

Flow Rate Calculator

Calculate flow rate from pipe diameter and velocity, a channel, or volume and time, in L/min, m³/h, US and imperial gpm and cfm, plus velocity and mass flow.

Calculator Details

Flow rate:176.715 L/minSee results ↓

Flow in a full round pipe, an open rectangular channel, from a volume and time, or the velocity from a flow

Inside (bore) diameter, not the nominal size

Average speed of the fluid across the section

Your Results

Flow rate: 176.715 L/min

Flow rate

176.715 L/min

46.6831 US gpm · 38.8718 imperial gpm · 10.6029 m³/h

Velocity

1.5 m/s

4.921 ft/s

Flow area

0.001964 m²

0.02113 ft²

Mass flow

176.72 kg/min

389.59 lb/min at 1,000 kg/m³

At 1.5 m/s the pipe carries 176.715 litres per minute (46.6831 US gpm, 38.8718 imperial gpm), or 10.6029 m³ per hour.

Compare scenarios

Save these inputs as a scenario, change them, and compare the results side by side.

Loading, available in a moment

Detailed Breakdown

The flow in every unitUS gallon = 3.785411784 L; imperial gallon = 4.54609 L; ft³ = 28.316846592 L.
UnitFlow
Litres per second (L/s)2.94524
Litres per minute (L/min)176.715
Cubic metres per hour (m³/h)10.6029
Cubic metres per second (m³/s)0.00294524
US gallons per minute (US gpm)46.6831
Imperial gallons per minute (imp gpm)38.8718
Cubic feet per minute (cfm)6.24062
Cubic feet per second (cfs)0.10401

How This Calculator Works

How it's calculated

Volumetric flow is Q = A × v, the flow area times the average velocity (the continuity equation). A full round pipe has A = π d² ÷ 4 using the inside diameter; a rectangular channel has A = width × depth. From a measured volume, Q = V ÷ t. Mass flow is ṁ = ρ × Q. Everything is converted to metres and seconds first, then to each unit with exact factors.

With your numbers

A = π × (50 mm = 0.05 m)² ÷ 4 = 0.0019635 m²
Q = 0.0019635 m² × 1.5 m/s = 0.00294524 m³/s
0.00294524 m³/s × 60,000 = 176.715 L/min; ÷ 0.003785411784 × 60 = 46.6831 US gpm
ṁ = 1,000 kg/m³ × 0.00294524 m³/s = 2.94524 kg/s

Frequently Asked Questions

What is the formula for flow rate?

Volumetric flow rate Q is the cross-sectional area of the flow times its average velocity: Q = A × v. For a round pipe running full, A = π × d² ÷ 4 using the inside diameter. If you know how much fluid moved and how long it took, Q = volume ÷ time. Keep the units consistent, for example square metres times metres per second gives cubic metres per second.

What is the difference between a US gallon and an imperial gallon?

A US gallon is 3.785411784 litres; the imperial gallon, still used for some pumps and older equipment in Canada and the UK, is 4.54609 litres, about 20% larger. So 1 US gpm = 3.78541 L/min and 1 imperial gpm = 4.54609 L/min. Check which gallon a Canadian pump or fixture rating uses: most new products quote US gpm and L/min.

How do I measure the flow from a tap or a garden hose?

Time how long it takes to fill a bucket of known size, then use the volume-over-time mode. A 10 L bucket that fills in 6 seconds means 100 L/min, or 26.42 US gpm. Repeat it two or three times and average the results.

Should I use the nominal pipe size or the inside diameter?

The inside diameter. Nominal sizes are trade names: a ½-inch copper or PEX line has a bore of roughly 13 to 16 mm depending on the type and wall thickness, and Schedule 40 and Schedule 80 pipe of the same nominal size have different bores. Look up the inside diameter for your pipe material and schedule, because flow varies with the diameter squared.

What water velocity is acceptable in household plumbing?

Plumbing codes and pipe manufacturers set maximum velocities, usually lower for hot water than for cold, to limit noise, erosion and pressure loss; check the limit for your pipe material. As an example, 15 L/min through a 16 mm bore moves at 1.24 m/s.

How do I convert flow rate to mass flow?

Multiply the volumetric flow by the fluid’s density: ṁ = ρ × Q. Water is about 1,000 kg/m³ (998 kg/m³ at 20 °C), so 1 litre per minute of water is about 1 kg per minute. Set the density under the advanced options for other fluids, using the figure from its data sheet.

Does this calculate how much flow a pipe can carry at a given pressure?

No. This calculator relates flow, area and velocity. The flow a pipe actually delivers depends on the pressure available and on friction losses along its length, which need the Darcy–Weisbach or Hazen–Williams equations, pipe roughness and fittings. Use the velocity this calculator gives to check that a chosen pipe size is reasonable.

What is cfm?

Cubic feet per minute, the usual unit for air flow in HVAC and for compressors in North America. One cfm is 28.316846592 litres per minute. The calculator works for gases as well as liquids, as long as you enter the average velocity and the duct area.

Flow from area × average velocity or volume ÷ time, with exact unit factors (NIST SP 811; imperial gallon from Canada’s Weights and Measures Act). Assumes a pipe running full and a uniform average velocity. Not included: pressure drop and friction losses (Darcy–Weisbach, Hazen–Williams), partly full pipes, open-channel flow from slope (Manning), pump curves and compressible gas flow.

Flow Rate Calculator: Litres per Minute, GPM and Pipe Velocity

By FindMySum · Last reviewed

A flow rate calculator tells you how much fluid passes a point each second, minute or hour. This one works four ways: from a round pipe's inside diameter and the flow velocity, from a rectangular channel's width, depth and velocity, from a volume and the time it took, or backwards from a known flow to the velocity in a pipe. It reports the answer in litres per second and minute, cubic metres per hour and second, US and imperial gallons per minute and cubic feet per minute and second, along with the mass flow for the fluid's density.

The formula

Volumetric flow rate, written Q, is the area the fluid flows through multiplied by its average velocity:

Q = A × v

For a round pipe running full, the area is A = π × d² ÷ 4, where d is the inside diameter. For a rectangular channel or duct it is width times the depth of the fluid. When you measure the flow directly by filling a container, the formula is simply Q = volume ÷ time.

Because flow depends on the diameter squared, a small change in pipe size matters a lot. Doubling the diameter quadruples the area, so at the same velocity the pipe carries four times the flow, or at the same flow the water moves at a quarter of the speed.

Worked example: the Canadian default

The calculator opens with a 50 mm bore pipe and water moving at 1.5 m/s:

  1. Area: π × 0.050² ÷ 4 = 0.0019635 m²
  2. Flow: 0.0019635 m² × 1.5 m/s = 0.00294524 m³/s
  3. Litres per minute: 0.00294524 × 60,000 = 176.715 L/min
  4. US gallons per minute: 176.715 ÷ 3.785411784 = 46.6831 US gpm
  5. Imperial gallons per minute: 176.715 ÷ 4.54609 = 38.8718 imperial gpm

Switch the region to the United States and the defaults change to a 2-inch bore at 5 ft/s, which gives 48.96 US gpm.

Units and the two gallons

Flow units combine a volume and a time, so there are many of them. The ones you will see most:

UnitCommon useEquals
L/minPlumbing fixtures, pumps (Canada, Europe)1/60 L/s
m³/hMunicipal water, process plants, HVAC1/3.6 L/s
US gpmPumps, irrigation, fire flow (US, much of Canada)3.785411784 L/min
Imperial gpmOlder Canadian and UK equipment4.54609 L/min
cfmAir flow in ducts, compressors28.316846592 L/min

The imperial gallon is about 20% larger than the US gallon. Canada's Weights and Measures Act still defines it (4.54609 litres exactly), and you will find it on older well pumps, farm equipment and some fuel references. Most new products sold in Canada quote L/min and US gpm, but check the label: mixing the two gallons gives a 20% error.

Measuring flow with a bucket test

To find the real flow from a tap, hose or well pump, fill a container of known size and time it with a stopwatch. A 20-litre pail that fills in 40 seconds means 0.5 L/s, which is 30 L/min or about 7.9 US gpm. Use the largest container you can and repeat the test a few times; a one-second timing error matters much less on a 40-second fill than on a 5-second one.

Velocity and choosing a pipe size

Turn the problem around and the calculator gives the velocity for a flow you need. Pipe and fitting manufacturers and plumbing codes limit velocity because fast water is noisy, causes water hammer when valves close, and erodes pipe walls, especially copper carrying hot water. If the velocity for your flow comes out above the limit for your material, choose a larger pipe. Remember to enter the inside diameter, not the nominal size: the bore of a "¾-inch" line depends on whether it is copper type L, type M, PEX or Schedule 40 PVC.

Mass flow

Some applications care about mass rather than volume, for example dosing chemicals or sizing a boiler. Mass flow is the volumetric flow times the density: ṁ = ρ × Q. Water at room temperature is close to 1,000 kg/m³, so a litre per minute is about a kilogram per minute. Change the density under the advanced options for other liquids or for air.

What the calculator does not do

It relates flow, area and velocity, which is all you need to convert units, measure a flow or check a pipe size. It does not predict how much a pipe will deliver from a given pressure, because that depends on friction along the pipe and through every elbow and valve. Engineers use the Darcy–Weisbach or Hazen–Williams equations for that, and Manning's equation for open channels driven by slope.

More questions

Why does water speed up when a hose is pinched?

The same volume has to pass every point each second, so A₁v₁ = A₂v₂. Shrinking the area at the nozzle forces the velocity up in proportion. In the classic textbook example, 0.5 L/s moves at about 2 m/s in a hose of 1.8 cm bore and about 25 m/s through a 5 mm nozzle.

How long will it take to fill my pool?

Divide the pool volume by the flow rate. Measure the hose flow with a bucket test first, then use the volume-over-time idea in reverse: 50,000 litres at 30 L/min takes about 1,667 minutes, or nearly 28 hours. The pool volume calculator gives the volume from the pool's shape.

Is flow rate the same as pressure?

No. Pressure is what pushes the fluid; flow rate is how much moves. A tap can have high pressure and almost no flow when it is nearly closed, and a wide pipe can carry a large flow at low pressure. The two are linked by the friction in the pipe and fittings, which this calculator does not model.

What flow rate do I need for a shower or a tankless water heater?

Fixtures are rated by their maximum flow, printed on the packaging in L/min or gpm. Add the flows of the fixtures that can run at the same time; that total is the flow the water heater or supply line has to deliver. A tankless heater's rating falls as the temperature rise it has to provide increases, so check its chart for your incoming water temperature.

How do I convert gpm to L/min in my head?

For US gallons, multiply by about 3.8; for imperial gallons, by about 4.5. So 10 US gpm is about 38 L/min and 10 imperial gpm about 45 L/min. The calculator uses the exact factors.

Sources

This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.

Spotted a wrong result or a bug? Report a problem

May we count your visits with Invoker Analytics? It keeps a random visitor number in your browser. Your calculator inputs are never sent. Privacy policy