Skip to content

MTBF and Reliability Calculator

Calculate MTBF, failure rate and FIT, reliability over a mission time, availability, series and parallel systems, and chi-square confidence bounds from test data.

Calculator Details

MTBF:5,000 hSee results ↓

Operating hours and failures from a test or field data, or an MTBF you already know

Hours run by all units together (10 units × 1,000 h = 10,000 h)

Failures during that time (0 allowed: you still get a lower bound)

For the chi-square bounds on MTBF

A two-sided interval, or a one-sided lower bound (the "demonstrated MTBF")

At a fixed time (time-terminated, Type I: the usual case) or at a set number of failures (failure-terminated, Type II)

Period for the reliability and failure probability

Average hours to restore service after a failure, for availability

1 for a single unit

Series: any failure stops the system. Parallel: active redundancy, the system works while one unit does

Your Results

MTBF: 5,000 h

MTBF

5,000 h

0.5704 years of continuous running

Failure rate

200,000 FIT

λ = 0.0002 per hour

Reliability over 1,000 h

81.873%

Chance of at least one failure 18.13%

Availability

99.9201%

About 7.01 h down a year

90% interval for MTBF

1,588 h – 28,140 h

Chi-square, time-terminated test

The data give an MTBF of 5,000 hours (λ = 200,000 FIT); the chance of running through the mission without a failure is 81.873% and availability is 99.92%.

Compare scenarios

Save these inputs as a scenario, change them, and compare the results side by side.

Loading, available in a moment

Reliability over time

Reliability over time

Detailed Breakdown

Reliability summary
MeasureValue
MTBF (point estimate)5,000 h
Failure rate λ0.0002 /h · 200,000 FIT
Reliability R(t)81.8731%
Probability of failure18.1269%
Inherent availability99.92006%
Lower confidence bound1,588.4 h
Upper confidence bound28,140 h

How This Calculator Works

How It’s Calculated

MTBF = T ÷ r · λ = 1 ÷ MTBF · R(t) = e−t/MTBF · A = MTBF ÷ (MTBF + MTTR)
Bounds: 2T ÷ χ²(1 − α/2, 2r + 2) to 2T ÷ χ²(α/2, 2r) (time-terminated)

Your calculation: MTBF = 10,000 h ÷ 2 failures = 5,000 h. Over 1,000 h, R = e^(−1,000 ÷ 5,000) = 81.873%, and availability = 5,000 ÷ (5,000 + 4) = 99.9201%. With 2 failures at 90% confidence the true MTBF is between 1,588.4 h and 28,140 h.

These formulas assume a constant failure rate: random failures during a product’s useful life, after early “infant mortality” failures and before wear-out. Few failures make the bounds wide; more test hours narrow them.

Frequently Asked Questions

How do you calculate MTBF?

Divide the total operating time of all units by the number of failures. Ten units running 1,000 hours each with 2 failures give 10,000 ÷ 2 = 5,000 hours. Count the hours of every unit, including those that never failed.

Does an MTBF of 50,000 hours mean a unit lasts 50,000 hours?

No. With a constant failure rate, only 36.8% of units are still running without a failure at one MTBF. MTBF describes the random failure rate during useful life, not the wear-out life; a fan rated at 50,000 hours MTBF may still wear out after five years.

What is FIT in reliability?

Failures In Time: the number of failures expected in 10⁹ device-hours (IEC 61709). FIT = 10⁹ ÷ MTBF in hours, so an MTBF of 5,000 hours is 200,000 FIT. Component failure rates are quoted in FIT because they are tiny per hour.

How do I calculate reliability from MTBF?

R(t) = e^(−t ÷ MTBF). With an MTBF of 5,000 hours, the chance of running 1,000 hours without a failure is 81.87%, and the chance of at least one failure is 18.13%.

How do you calculate availability?

Inherent availability A = MTBF ÷ (MTBF + MTTR). An MTBF of 5,000 hours and a 4-hour mean time to repair give 99.9201%, about 7.01 hours of downtime a year. Operational availability also counts waiting for parts, travel and maintenance.

What is a confidence interval for MTBF?

A range that contains the true MTBF with a chosen confidence, from the chi-square distribution. The NIST handbook's example of 800 hours with 2 failures gives an estimate of 400 hours and a 90% interval of 127.1 to 2,251 hours: two failures say very little. With no failures, only a lower bound exists: 267 hours at 95% after 800 failure-free hours.

How does redundancy change MTBF?

In series, any failure stops the system: two units of 50,000 hours give 25,000 hours. In active parallel the system runs while one unit works: two units give 50,000 × (1 + ½) = 75,000 hours, and much better reliability over short missions (99.9608% over 1,000 hours). Redundancy pays most when failed units are repaired quickly.

What is the difference between MTBF and MTTF?

MTBF (mean time between failures) is used for repairable equipment; MTTF (mean time to failure) for parts that are replaced, not repaired, such as a light bulb or a resistor. With a constant failure rate the arithmetic is the same, so this calculator works for both.

Uses the constant-failure-rate (exponential) model of the NIST/SEMATECH e-Handbook of Statistical Methods (§8.1.7, chi-square bounds §8.4.5.1) and MIL-HDBK-338B, with FIT as defined in IEC 61709:2017; time- and failure-terminated bounds are labelled. It leaves out infant-mortality and wear-out failures (Weibull and other life distributions), parts-count and stress predictions (MIL-HDBK-217, Telcordia SR-332, IEC 61709 stress factors), standby and k-out-of-n redundancy, common-cause failures, repair during a mission and operational availability (logistics and maintenance delays). A year is 8,766 hours.

MTBF Calculator: Failure Rate, FIT, Reliability, Availability and Confidence Bounds

By FindMySum · Last reviewed

Mean time between failures (MTBF) is the standard yardstick for how often repairable equipment breaks down. From it follow the failure rate, the chance of getting through a mission without a failure, the share of time the equipment is available, and what redundancy buys. This MTBF calculator works all of those out, either from your own operating hours and failure count or from an MTBF you already have, and from test data it gives chi-square confidence bounds on the true MTBF.

MTBF and failure rate

From test or field data,

MTBF = total operating time ÷ number of failures

where the operating time adds up the hours of every unit, failed or not. The failure rate is its inverse, λ = 1 ÷ MTBF. The calculator opens with 10,000 operating hours and 2 failures: an MTBF of 5,000 hours and a failure rate of 0.0002 per hour.

Component failure rates are tiny per hour, so they are quoted in FIT, failures in time: failures per 10⁹ device-hours, as defined in IEC 61709. FIT = λ × 10⁹, here 200,000 FIT. A good resistor might be 0.1 FIT; a complex processor tens of FIT.

Reliability over a mission

If failures are random and the failure rate is constant, the time to failure follows the exponential distribution, and the probability of running for a time t without a failure is

R(t) = e^(−t ÷ MTBF)

Over a 1,000-hour mission with an MTBF of 5,000 hours, R = e^(−0.2) = 81.9%, so there is an 18.1% chance of at least one failure. At t = MTBF, R is only 36.8%, which surprises many people: MTBF is not a guaranteed life.

Availability

Equipment that is repaired spends some time down. Inherent availability, counting only the repair itself, is

A = MTBF ÷ (MTBF + MTTR)

With a 4-hour mean time to repair, A = 5,000 ÷ 5,004 = 99.92%, about 7 hours of downtime a year. Operational availability, which adds logistics delays and maintenance, is lower.

Series and parallel systems

For n identical units:

  • Series, where any failure stops the system: R = Rⁿ and the MTBF is MTBF ÷ n. A chain of parts is only as reliable as all of them together.
  • Active parallel, where the system runs while one unit works: R = 1 − (1 − R)ⁿ, and the MTBF is MTBF × (1 + ½ + … + 1/n).

Redundancy improves reliability over short missions enormously, but the MTBF of two units in parallel is only 1.5 times one unit's, because once one has failed the other runs alone. The real benefit comes when failed units are repaired quickly.

Confidence bounds from test data

A handful of failures gives an uncertain estimate. The chi-square distribution turns your data into bounds on the true MTBF, as set out in the NIST/SEMATECH e-Handbook (§8.4.5.1). For a test that stops at a set time (time-terminated, Type I), the two-sided interval at confidence 1 − α runs from

2T ÷ χ²(1 − α/2, 2r + 2) to 2T ÷ χ²(α/2, 2r)

with χ² the left-tail chi-square quantile, T the total time and r the failures. A test that stops at a set number of failures (failure-terminated, Type II) uses 2r degrees of freedom for the lower bound too. The calculator labels both and also gives the one-sided lower bound, the "demonstrated MTBF" quoted in reliability test plans.

The NIST handbook's example, 800 hours with 2 failures, has a point estimate of 400 hours but a 90% interval of 127 to 2,251 hours. With zero failures there is no point estimate and no upper bound, but there is a lower bound: 800 failure-free hours demonstrate 267 hours at 95% confidence.

The reliability chart

The chart plots R(t) for one unit and, if you entered more than one, for the system, out to three times the MTBF. The curve falls to 36.8% at one MTBF and 5% at three. Parallel systems stay near 100% for longer and then drop; series systems fall faster from the start.

When the exponential model doesn't apply

The constant failure rate fits the useful-life part of the bathtub curve. Early failures from manufacturing defects and wear-out of mechanical parts, fans, batteries and electrolytic capacitors need other models, usually the Weibull distribution. Predictions from parts counts (MIL-HDBK-217, Telcordia SR-332) and stress factors (IEC 61709) are a separate exercise. Use this calculator for the arithmetic of a known or measured constant rate.

More questions

What is the bathtub curve?

A plot of failure rate over a product's life. It starts high (early failures from manufacturing defects), falls to a low, roughly constant level during useful life (random failures), and rises again as parts wear out. MTBF and the exponential model describe the flat bottom of the bathtub only.

Why do datasheet MTBF figures look so large?

They are usually predictions from parts-count methods such as Telcordia SR-332 or MIL-HDBK-217, at a set temperature, for the useful-life period. A power supply rated at 500,000 hours does not last 57 years; it means that in a large population about one unit in 500 fails per 1,000 hours of running at that temperature.

How many test hours do I need to demonstrate an MTBF?

With no failures allowed, a time-terminated test must run for MTBF × (−ln(1 − C)) hours to show the MTBF at confidence C: about 2.3 × MTBF at 90% and 3.0 × MTBF at 95%. Spreading the hours over many units shortens the calendar time. Allowing a failure or two lengthens the test but makes it less likely to fail a good design.

Does temperature affect MTBF?

Strongly, for electronics. Many failure mechanisms follow the Arrhenius law, and a common rule of thumb is that the failure rate roughly doubles for every 10 °C to 20 °C rise. Compare MTBF figures only at the same temperature, and check the temperature a datasheet figure assumes.

What is MTTR?

Mean time to repair: the average time from a failure until the equipment is working again, including diagnosis, repair and testing. It does not include waiting for spare parts or a technician unless you count operational rather than inherent availability.

Sources

This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.

Spotted a wrong result or a bug? Report a problem

May we count your visits with Invoker Analytics? It keeps a random visitor number in your browser. Your calculator inputs are never sent. Privacy policy