Skip to content

Framing Calculator

Wall framing take-off: studs at 16 or 24 in (400 or 600 mm) on centre, corners, king and jack studs, plates, headers and cripples, with board feet and cost.

Calculator Details

Studs to buy:31 × 2×4See results ↓

Total length of the wall (or of all walls added together)

Feet and inches, or metres and millimetres

Sets the precut stud length

16 in (400 mm) or 24 in (600 mm) on centre: your code and the load decide which is allowed

2×6 (38 × 140 mm) for thicker insulated exterior walls

For crooked boards, blocking and mistakes

Each adds 2 studs

Where another wall meets this one; each adds 2 studs

Openings to the floor

Openings with a sill

Door width + about 2 in (a 36 in door has a 38 in rough opening)

From the window maker’s rough-opening size

Built-up header of two plies; the size depends on the span and load (check your code’s span table)

Length of the boards you buy for plates (ft)

Your Results

Studs to buy: 31 × 2×4

Studs to buy

31 × 2×4

92 5/8 in precut, 16 in on centre

Plate boards

6 × 16 ft

2 per row × 3 rows

Header lumber

13.3 ft

2×10, 2 plies

Board feet

245.7

A take-off, not a structural design: header size and stud spacing depend on the span and load. Check the span tables in your building code (NBC 9.23 / IRC R602) or ask your building department.

Frame this wall with 31 2x4 studs (92 5/8 in precut, 16 in on centre, with 10% extra), 6 plate boards of 16 ft and 13.3 ft of 2x10 header: 245.7 board feet in all.

Compare scenarios

Save these inputs as a scenario, change them, and compare the results side by side.

Loading, available in a moment

Board feet by part

Board feet by part

Detailed Breakdown

Framing take-off
ItemPiecesSizeLengthBoard feet
Studs (incl. extra)312×492 5/8 in precut159.5
Plate boards (1 bottom + 2 top rows)62×416 ft64.0
Headers (2 plies × 2 openings)42×10160 in total22.2
Cripple studs (cut from displaced studs)62×4cut to fit—
Rough sills (cut from studs)12×436 in total—
Total245.7

How This Calculator Works

How the studs are counted

Common studs = ⌈wall length ÷ spacing⌉ + 1

+ 2 per corner + 2 per intersection + 2 king and 2 jack studs per opening, then + extra %

Headers: 2 plies × (rough opening + 3 in) per opening

Your numbers: 20 ft at 16 in = 16 common studs, + 4 at corners, + 4 king and 4 jack studs = 28; × 1.1 = 31 studs. The 6 cripples above and below openings are cut from the common studs that the openings displace.

Frequently Asked Questions

How many studs do I need for a wall?

Divide the wall length by the stud spacing, round up and add one for the end: a 20 ft wall at 16 in on centre needs 240 ÷ 16 = 15, plus 1 = 16 common studs. Then add two studs for each corner and wall intersection, two king and two jack studs for each door or window, and about 10% extra for crooked boards and blocking.

What is the standard stud spacing in Canada and the US?

Most walls are framed at 16 in (400 mm) on centre; 24 in (600 mm) is allowed for many walls under the National Building Code of Canada (Table 9.23.10.1) and the International Residential Code (Table R602.3(5)), depending on the stud size, wall height and the floors and roof the wall carries. Your code and local building department decide what applies.

How long are precut studs?

Precut studs are 92 5/8 in for 8 ft, 104 5/8 in for 9 ft, 116 5/8 in for 10 ft. With a single bottom plate and a double top plate (three 1½ in plates), a 92 5/8 in stud makes a 97 1/8 in wall: room for 8 ft drywall plus the ceiling board and a small gap at the floor.

What are king, jack and cripple studs?

At an opening, a full-height king stud on each side frames the opening, and a shorter jack (trimmer) stud next to it carries the header. Cripple studs are short studs above the header and below a window’s rough sill that keep the stud layout going. The calculator assumes the cripples are cut from the common studs that the opening displaces.

How long should a header be?

The rough opening plus 3 in, so the header bears 1½ in on each jack stud. A built-up header is usually two plies of 2× lumber with a spacer for a 2×4 wall. Its depth (2×6 to 2×12 or engineered lumber) depends on the span and the load above: use the header span tables in your code.

How many plates does a wall need?

Most load-bearing walls have one bottom (sole) plate and two top plates, so three times the wall length in plate lumber. Joints in the two top plates are staggered, and the top plate laps over at corners and intersections to tie the walls together.

How do I calculate board feet for framing lumber?

Softwood lumber is measured at its nominal size: board feet = thickness × width × length in inches ÷ 144. A 2×4 precut stud (92 5/8 in) is 2 × 4 × 92.625 ÷ 144 = 5.15 board feet, and a 16 ft 2×4 plate is 10.67 board feet. See the board foot calculator for other sizes.

A material take-off, not a structural design. Conventions: one bottom and two top plates, two studs per corner and per intersection, two king and two jack studs per opening, two-ply headers bearing 1½ in on each side; precut stud lengths from lumber producers; spacing per NBC 2020 9.23.10 (same in NBC 2025) and IRC 2021 R602.3. It leaves out header and stud sizing for loads (use your code's span tables), rake and gable walls, custom wall heights, fire blocking, sheathing, nails and connectors, engineered lumber, and advanced framing layouts (California corners, ladder blocking, single top plates). Prices are what you enter.

Framing Calculator: Studs, Plates and Headers for a Wall

By FindMySum · Last reviewed

Framing a wall takes more lumber than "one stud every 16 inches". Corners, intersections, door and window openings each add studs, every wall has three rows of plates, and every opening needs a header. This calculator does the take-off for a wall (or for several walls added together): studs to buy, plate boards, header lumber, cripples, board feet and cost. It counts material; it doesn't size anything for loads.

Step 1: common studs

Studs are laid out from one end of the wall at a fixed spacing, 16 in (400 mm) or 24 in (600 mm) on centre, with one at each end. So:

common studs = ⌈wall length ÷ spacing⌉ + 1

A 20 ft (240 in) wall at 16 in needs 240 ÷ 16 = 15, plus 1 = 16 common studs. The calculator lays these out across openings too, because the studs that a door or window displaces are cut up to make the cripples, rough sills and blocking.

Step 2: corners, intersections and openings

  • Corners: two extra studs per corner (a three-stud corner), so there is backing for the drywall on the inside.
  • Intersections: two extra studs where another wall meets this one, for the same reason.
  • Openings: each door or window has a full-height king stud on each side and a shorter jack (trimmer) stud inside each king that carries the header: four studs per opening.

Then add about 10% for crooked boards, blocking and mistakes.

Worked example (the calculator's defaults). A 20 ft wall, 8 ft high, 2×4 at 16 in on centre, two corners, one door with a 38 in rough opening and one window with a 36 in rough opening: 16 common studs + 4 corner studs + 4 king studs + 4 jack studs = 28; with 10% extra, 31 studs.

Step 3: plates

Most walls have a single bottom plate and a double top plate. That is three rows the length of the wall. With 16 ft plate boards, each row of a 20 ft wall takes two boards, so six in total. The joints in the two top plates are offset, and the upper plate laps over the walls at corners and intersections.

Step 4: headers and cripples

A header spans each opening and sits on the jack studs, so it is the rough opening plus 3 in long (1½ in of bearing at each end). A typical built-up header is two plies of 2× lumber. In the example, the door header is 41 in and the window header 39 in, two plies each: 160 in, or 13.3 ft of header stock.

Cripples are the short studs above a header and below a window's rough sill that continue the stud layout. Above each opening there are ⌈width ÷ spacing⌉ − 1 of them; below a window, the same number again. They come from the displaced common studs, so they don't add to the order.

How deep the header must be (2×6 to 2×12, or engineered lumber) depends on the span and on the floors and roof above. That is a structural question: use the header span tables in Part 9 of the National Building Code of Canada or the International Residential Code, or ask your building department.

Stud length

Precut studs are made for standard wall heights: 92 5/8 in for 8 ft walls, 104 5/8 in for 9 ft walls and 116 5/8 in for 10 ft walls. Add three 1½ in plates and a 92 5/8 in stud gives a 97 1/8 in frame, which fits a sheet of 8 ft drywall on the wall, the ceiling board above and a small gap at the floor.

Board feet

Softwood framing lumber is measured at its nominal size, so board feet = thickness × width × length (in) ÷ 144. A 92 5/8 in 2×4 is 5.15 board feet; a 16 ft 2×4 plate 10.67. The example wall comes to 159.5 board feet of studs, 64 of plates and 22.2 of 2×10 header: 245.7 board feet in all.

Canada and the US

The arithmetic is the same on both sides of the border, and Canadian lumberyards sell the same 2×4 and 2×6 sizes (38 × 89 and 38 × 140 mm). The rules that decide spacing, stud size and headers come from different codes: Section 9.23 of the National Building Code of Canada (and the provincial codes based on it) and Section R602 of the International Residential Code in the US.

What the calculator leaves out

It doesn't size studs or headers for loads, and doesn't handle gable or rake walls, custom heights, fire blocking, sheathing, fasteners or advanced framing layouts. Use it to price and order material; follow your code and your building department for the structure.

More questions

Should I use 2×4 or 2×6 studs for exterior walls?

2×6 walls leave room for thicker insulation (a 140 mm cavity instead of 89 mm), which is why they are common for exterior walls in colder parts of Canada and in energy codes that ask for higher wall R-values. They also allow 24 in spacing in more situations. Interior partitions are usually 2×4.

What is advanced framing?

Advanced (or optimum value) framing uses less lumber: studs at 24 in on centre, two-stud or California corners, ladder blocking at intersections, single top plates with aligned framing and right-sized headers. It saves wood and leaves more room for insulation, but each technique has to be allowed by your code and designed so loads line up.

How much extra lumber should I order?

Ten percent extra studs is a common allowance for crooked or split boards, blocking, backing for cabinets and fixtures, and mistakes. Lumber with a lot of wane or crook may need more. Plates and headers are bought by length, so plan the cut list to limit offcuts.

Do I need a permit to frame a wall?

New construction, additions and changes to load-bearing walls almost always need a building permit in Canada and the US. Moving a non-load-bearing partition may not, depending on your municipality. Ask your building department before you start, especially if a wall carries floor or roof loads.

What is the difference between a load-bearing and a partition wall?

A load-bearing wall carries weight from the floors or roof above to the foundation, so its studs, headers and plates are sized for that load. A partition wall only divides space. Removing or cutting a large opening in a load-bearing wall needs a properly sized beam and often an engineer.

Sources

This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.

Spotted a wrong result or a bug? Report a problem

May we count your visits with Invoker Analytics? It keeps a random visitor number in your browser. Your calculator inputs are never sent. Privacy policy