Wall Framing Calculator: Studs, Plates and Headers (US)
By FindMySum · Last reviewed
This framing calculator estimates the lumber for stud walls the way most American houses are built: 2×4 or 2×6 studs, usually 16 inches on center, on a single bottom plate with a double top plate. It counts the common studs along the wall, adds two studs for each corner and each wall intersection, a king stud and a jack (trimmer) stud on each side of every door and window, the extra you ask for, the plate boards for three rows, and the length of the built-up headers over the openings.
Worked example: a 32 ft exterior wall
The US page starts with a wall 32 ft long and 8 ft high, 2×4 studs at 16 inches on center, two corners, one door with a 38 inch rough opening, two windows of 36 inches, 2×10 headers, 16 ft plate boards and 10% extra studs.
- Common studs: 32 × 12 ÷ 16 + 1 = 25.
- Corners: 2 × 2 = 4 studs.
- Openings: 3 openings × (a king and a jack on each side) = 6 king studs and 6 jacks.
- Before the extra: 41 studs; with 10% added, 46 studs.
- Plates: three rows of 32 ft, two 16 ft boards each, so 6 plate boards.
Headers come to about 19.8 ft of 2×10 for the two-ply headers, and the wall uses about 334 board feet of lumber in all. The studs are 92⅝ inch precuts for the 8 ft wall.
Headers and spans
A header carries the load over an opening to the jack studs. The IRC header tables (R602.7) size headers by the span, the building width and the loads above, so a 3 ft window in a one-story wall may need only a pair of 2×6s while a 6 ft patio door under a floor needs 2×10s or 2×12s. Many builders use 2×10 or 2×12 headers everywhere for simplicity, at the cost of a little more lumber and less insulation. In non-bearing interior walls headers can be a single flat 2×4.
Before you buy
Lumber yards sell studs in bundles and plates in 8 to 16 ft lengths; longer plates mean fewer joints, but joints in the top plates must be offset at least 24 inches. Pressure-treated lumber is required for a bottom plate on concrete in contact with the ground or near it. Add blocking for cabinets, grab bars and the TV mount now: it is much easier before the drywall goes up.
For metric framing in millimetres (studs at 400 or 600 mm), use the framing calculator.
Sources
This article explains how the calculator works and is general information, not financial, tax or legal advice. Rules change; check the sources above or a qualified professional before you act.