Skip to content

Beer-Lambert Law Calculator

Solve the Beer-Lambert law A = εlc for absorbance, concentration, molar absorptivity or path length, fit a calibration curve and find DNA concentration from A260.

Calculator Details

Absorbance A:0.4976See results ↓

Solve A = εlc, fit a calibration curve to standards, or find a DNA or RNA concentration from A260

The unknown in A = ε·l·c

At your wavelength; NADH at 340 nm is 6,220 L/(mol·cm)

Cuvette width; standard cuvettes are 1 cm

Of the absorbing species

Your Results

Absorbance A: 0.4976

Absorbance A

0.4976

31.8% of the light is transmitted

Absorbance

0.4976

T = 10⁻ᴬ = 31.8%

Concentration

8 × 10⁻⁵ mol/L

80 µmol/L

ε × l

6,220 L/mol

ε = 6,220, l = 1 cm

Absorbance 0.4976 (31.8% transmitted) with ε = 6,220 L/(mol·cm), l = 1 cm and c = 80 µmol/L.

Compare scenarios

Save these inputs as a scenario, change them, and compare the results side by side.

Loading, available in a moment

Absorbance against concentration

Absorbance against concentration

Detailed Breakdown

Beer–Lambert values
QuantityValue
Absorbance A0.4976
Transmittance T31.798%
Molar absorptivity ε6,220 L/(mol·cm)
Path length l1 cm
Concentration c8 × 10⁻⁵ mol/L

How This Calculator Works

How It’s Calculated

A = ε·l·c · A = −log₁₀ T = 2 − log₁₀(%T)
Calibration: A = slope·c + intercept (least squares), c_unknown = (A − intercept) ÷ slope
Nucleic acids: c (ng/µL) = A260 × factor × dilution ÷ l (cm); dsDNA 50, ssDNA 33, RNA 40

Your calculation: A = ε·l·c = 6,220 × 1 × 8 × 10⁻⁵ = 0.4976, so T = 10^−0.4976 = 31.8%.

The law holds for dilute solutions of a single absorbing species with monochromatic light. Above an absorbance of about 1–1.5, stray light and molecular interactions bend the line, so dilute the sample.

Frequently Asked Questions

What is the Beer–Lambert law?

The absorbance of a solution is proportional to the concentration of the absorbing species and to the distance the light travels through it: A = εlc. ε is the molar absorptivity (L/(mol·cm)), a property of the substance at one wavelength, l is the path length in cm and c the concentration in mol/L. Absorbance itself has no unit.

How do I convert transmittance to absorbance?

A = −log₁₀ T, or A = 2 − log₁₀(%T) when T is a percentage. 100% transmittance is A = 0, 10% is A = 1 and 1% is A = 2. With 10% transmittance, ε = 6220 L/(mol·cm) and a 1 cm cell, the concentration is 160.8 µmol/L.

How do I find a concentration from an absorbance?

Divide by ε and the path length: c = A ÷ (εl). NADH has ε = 6220 L/(mol·cm) at 340 nm, so an 80 µmol/L solution in a 1 cm cuvette gives A = 0.4976, and an unknown reading 0.5 is 80.4 µmol/L. When ε isn’t known, use a calibration curve from standards instead.

Why use a calibration curve instead of ε?

A calibration curve measured on your own instrument, at your wavelength and in your solvent, corrects for the spectrometer’s bandwidth, the blank and the matrix. Fit a straight line through standards that bracket the unknown, check that R² is close to 1 (0.995 or better is a common target) and read the unknown off the line, never far outside the standards’ range.

How is DNA concentration calculated from A260?

Multiply the absorbance at 260 nm by an average conversion factor for a 1 cm path: 50 µg/mL for double-stranded DNA, 33 for single-stranded DNA and 40 for RNA, then by any dilution. An A260 of 0.75 for dsDNA is 37.5 ng/µL. Microvolume instruments use shorter paths and normalise the reading to 1 cm.

What do the A260/A280 and A260/A230 ratios mean?

They flag contamination. Proteins absorb at 280 nm, so a pure DNA sample has A260/A280 of about 1.8 and RNA about 2.0; lower values suggest protein or phenol. Salts, guanidine and carbohydrates absorb near 230 nm, so A260/A230 should be about 2.0 to 2.2. The default sample has ratios of 1.83 and 2.08.

Why does the Beer–Lambert law fail at high absorbance?

At high absorbance almost no light reaches the detector, so stray light and detector noise dominate. In concentrated solutions molecules interact and the refractive index changes, and with broadband light ε varies across the band. All of these bend the line. Most instruments are reliable between about 0.1 and 1; dilute stronger samples.

Uses the Beer–Lambert law as defined in the IUPAC Gold Book, an ordinary least-squares line for calibration curves, and the average A260 factors (dsDNA 50, ssDNA 33, RNA 40 µg/mL) published by New England Biolabs and Agilent. The purity ratios are rules of thumb, not standards. It assumes one absorbing species, monochromatic light and dilute solutions; it leaves out stray light and instrument non-linearity at high absorbance, scattering from turbid samples, mixtures of absorbers (multi-wavelength analysis), weighted or forced-zero calibration fits and sequence-specific extinction coefficients for short oligonucleotides.

Beer-Lambert Law Calculator: Absorbance, Concentration and DNA from A260

By FindMySum · Last reviewed

Shine light through a coloured solution and some of it is absorbed. The more concentrated the solution and the longer the path through it, the more light disappears. The Beer–Lambert law turns this into a straight line, which is why a spectrophotometer can measure the concentration of almost anything that absorbs light, from the iron in water to the protein in a blood sample. This Beer-Lambert law calculator solves A = εlc for whichever quantity you don't know, converts between absorbance and transmittance, fits a calibration line through your standards and reads an unknown off it, and works out DNA and RNA concentrations from the absorbance at 260 nm with the usual purity ratios.

The law

A = ε·l·c

  • A is the absorbance (unitless), defined as A = log₁₀(I₀ ÷ I), where I₀ is the light entering the sample and I the light leaving it
  • ε is the molar absorptivity (or molar extinction coefficient) in L/(mol·cm), a property of the substance at a given wavelength
  • l is the path length through the sample in cm, 1 cm for a standard cuvette
  • c is the concentration in mol/L

Transmittance is the fraction of light that gets through, T = I ÷ I₀, so A = −log₁₀ T. Because the scale is logarithmic, each absorbance unit means ten times less light: A = 1 lets 10% through, A = 2 only 1%. Enter the reading as absorbance or as percent transmittance; the calculator converts with A = 2 − log₁₀(%T).

Worked example: NADH at 340 nm

The calculator opens with NADH, the coenzyme followed in countless enzyme assays, which has a molar absorptivity of 6220 L/(mol·cm) at 340 nm. For an 80 µmol/L solution in a 1 cm cuvette:

  • A = 6220 × 1 × 80 × 10⁻⁶ = 0.4976
  • T = 10^−0.4976 = 31.8% of the light is transmitted

Run backwards, a reading of A = 0.500 gives c = 0.500 ÷ (6220 × 1) = 8.04 × 10⁻⁵ mol/L, or 80.4 µmol/L. Choose "solve for" to find ε from a known concentration, or the path length from known ε and c.

Calibration curves

ε values from the literature were measured on someone else's instrument, at a precise wavelength, in a particular solvent. For quantitative work, chemists measure a set of standards of known concentration and fit a straight line through absorbance against concentration. Type the standards as concentration, absorbance pairs separated by semicolons or new lines, in any concentration unit. The calculator fits the least-squares line A = slope·c + intercept, the same as Excel's SLOPE and INTERCEPT functions, reports R², shows each standard's residual, and converts the unknown's absorbance into a concentration in the same unit. With the default standards, the line is A = 0.01214·c + 0.00084 with R² = 0.99994, so an unknown reading 0.350 is 28.8 units.

Keep the unknown within the range of the standards; reading beyond them assumes the line stays straight where you haven't checked it, and the calculator warns when the result is extrapolated. If the slope divided by the path length is in mol/L units, it is your instrument's ε.

DNA and RNA concentration

Nucleic acids absorb strongly at 260 nm. Rather than a molar ε, which depends on the sequence, labs use average mass-based factors for a 1 cm path: one absorbance unit at 260 nm corresponds to about 50 µg/mL of double-stranded DNA, 33 µg/mL of single-stranded DNA and 40 µg/mL of RNA. Multiply by any dilution and divide by the path length:

c (ng/µL) = A260 × factor × dilution ÷ path (cm)

An undiluted dsDNA sample reading 0.75 at 260 nm contains 0.75 × 50 = 37.5 ng/µL. Short oligonucleotides need a sequence-specific coefficient instead of these averages.

Two ratios check the sample's purity. Proteins absorb at 280 nm, so pure DNA gives A260/A280 near 1.8 and RNA near 2.0; a markedly lower ratio suggests protein or phenol. Guanidine salts, EDTA, carbohydrates and phenol absorb near 230 nm, so A260/A230 should be around 2.0 to 2.2. The default sample, with A280 = 0.41 and A230 = 0.36, gives 1.83 and 2.08, both in range.

Reading the chart

In the Beer–Lambert mode the chart plots absorbance against concentration from zero to twice your value, a straight line through the origin with slope εl, with your point marked. In the calibration mode it shows the fitted line and marks the unknown. In the nucleic acid mode it compares the three absorbance readings.

Limits

The law assumes monochromatic light, a single absorbing species, a dilute solution and a clear sample. At absorbances above about 1 to 1.5, stray light and the detector's limits make readings unreliable, and in concentrated solutions molecules interact and change ε; dilute the sample instead. Turbid samples scatter light and read higher than their true absorbance. Mixtures of absorbing species need measurements at several wavelengths. The A260 factors are averages for long nucleic acids, and the purity ratios are rules of thumb from instrument makers, not standards.

More questions

Who were Beer and Lambert?

Johann Heinrich Lambert described in 1760 how light weakens exponentially with the thickness of an absorbing material, building on Pierre Bouguer's work. August Beer showed in 1852 that the absorption also depends on concentration. The combined law is sometimes called the Beer–Lambert–Bouguer law.

What is a blank and why do I need one?

A cuvette filled with the solvent and reagents but no analyte. Measuring it first and setting it to zero absorbance removes the light lost to the cuvette walls, reflections and the solvent itself, so the reading reflects only the substance you want to measure.

How do I choose the wavelength?

Usually the wavelength of maximum absorbance (λmax) of the analyte. There ε is largest, so the method is most sensitive, and the absorbance changes least if the instrument's wavelength drifts slightly. Avoid wavelengths where other components of the sample also absorb strongly.

Can absorbance be negative?

Only if the sample transmits more light than the blank, which points to a measurement problem: a dirty or mismatched cuvette for the blank, a bubble, or a sample more dilute than the blank's background. Repeat the blank and the reading.

What is the difference between absorbance and optical density?

In chemistry they are often used interchangeably. In microbiology, optical density (OD600) of a cell culture is mostly light scattered by the cells rather than absorbed, so it depends on the instrument's optics and the Beer–Lambert law applies only loosely. Calibrate OD readings against cell counts on your own instrument.

Does the Beer–Lambert law apply to fluorescence?

Not directly. Fluorescence intensity is proportional to concentration only at very low absorbance, below about 0.05, where the light absorbed is small. At higher concentrations the sample absorbs its own excitation and emission light (the inner-filter effect) and the signal levels off.

Sources

This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.

Spotted a wrong result or a bug? Report a problem

May we count your visits with Invoker Analytics? It keeps a random visitor number in your browser. Your calculator inputs are never sent. Privacy policy