Skip to content

Lumens to Lux Converter (lm to lx by Area)

Convert lumens to lux over an area in m² or ft²: lux = lumens ÷ area. See foot-candles too, a 10 to 10,000 lumen table and a worked example.

Calculator Details

800 lumens:40 lxSee results ↓

Total light output in lumens (on the package; a 60 W-equivalent bulb is about 800 lm)

Floor or surface area the light is spread over

Square metres or square feet

Your Results

800 lumens: 40 lx

800 lumens

40 lx

over 20 m²

Conversion factor

1 lm = 0.05 lx

over 20 m²

Area

20 m²

215.278 ft²

Foot-candles

3.71612 fc

illuminance at the surface

800 lumens over 20 m² is 40 lux.

Detailed Breakdown

Lumens to lux over 20 m²
Lumens (lm)Lux (lx)
10 lm0.5 lx
30 lm1.5 lx
50 lm2.5 lx
100 lm5 lx
300 lm15 lx
500 lm25 lx
1,000 lm50 lx
2,000 lm100 lx
5,000 lm250 lx
10,000 lm500 lx

Every row uses the same setting (over 20 m²); change it above and the table follows.

How This Calculator Works

How it's calculated

lux = lumens ÷ area (m²)

Your numbers: 800 lm ÷ 20 m² = 40 lx.

Frequently Asked Questions

How do I convert lumens to lux?

Divide the lumens by the area in square metres: lux = lumens ÷ m². An 800-lumen bulb lighting 20 m² gives 800 ÷ 20 = 40 lux on average. Halve the area and the lux doubles.

How many lux does an 800 lumen bulb give?

It depends on the area it lights: 800 lux over 1 m², 80 lux over 10 m², 40 lux over 20 m². In a real room fewer lux reach the floor because the fixture and surfaces absorb some of the light.

Is 1 lumen equal to 1 lux?

Only over exactly one square metre. One lumen spread over one square metre is one lux; over 2 m² it is 0.5 lux. Lumens measure total output, lux measure light per area.

How do I get foot-candles from lumens?

Divide the lumens by the area in square feet: foot-candles = lumens ÷ ft². This page shows foot-candles beside the lux for whatever area unit you choose; 1 foot-candle is 10.764 lux.

How many lux is good for reading?

EN 12464-1 sets 500 lux for reading and writing at office desks; homes are often lit lower, with 300 to 500 lux at a reading lamp. Use the light converter hub to work out the lumens a room needs.

Why does my light meter show less lux than this?

This page assumes every lumen lands on the area. In practice fixtures trap some light, dark walls and ceilings absorb more, and light near the walls is lost, so a meter in the middle of the room often reads 40 to 60% of the simple estimate.

Can I add the lumens of several lamps?

Yes. Lumens add up, so four 800-lumen downlights give 3,200 lumens; divide that total by the area for the average lux.

Lumens to Lux: How Bright a Lamp Makes a Surface

By FindMySum · Last reviewed

Lumens to lux answers a practical question: if I put this lamp in this space, how bright will the surface be? The lumens on the package measure the lamp's total light output. Lux measure what arrives on each square metre. To go from one to the other you divide by the area, and this guide shows how, with the converter's default numbers.

The formula

One lux is one lumen per square metre (SI Brochure), so:

lux = lumens ÷ area in m²

The converter starts with an 800-lumen bulb, the usual "60 W equivalent", lighting 20 m²:

  • 800 lm ÷ 20 m² = 40 lux
  • in foot-candles: 40 × 0.09290304 = 3.72 fc

Forty lux is enough to find your way around but too dim to read comfortably. The same bulb over a 4 m² desk area would give 200 lux; over a 1 m² shelf, 800 lux.

Square feet and foot-candles

If you measure the room in square feet, either convert to square metres (multiply by 0.09290304) or work in foot-candles, which are lumens per square foot. An 800-lumen bulb over 80 ft² gives 10 foot-candles, which is 107.6 lux. The converter accepts either area unit and always shows both lux and foot-candles, so you can read whichever your specification uses.

Reading the value table

The table on the page divides each value from 10 to 10,000 lumens by your area. Because the relationship is a straight line, the rows are just multiples of one another: at 20 m², every 1,000 lumens adds 50 lux. That makes the table handy for comparing lamp sizes. A 1,600-lumen "100 W equivalent" bulb gives twice the lux of an 800-lumen one in the same space, and a 5,000-lumen LED panel gives 250 lux over 20 m².

Why measured lux is lower

The formula assumes every lumen lands evenly on the area. Real rooms fall short in three ways. First, part of the light leaves the lamp sideways or upwards and is absorbed by the fitting, walls and ceiling; pale surfaces bounce much of it back, dark ones do not. Second, light is uneven, brightest under the lamp and dimmer near the walls. Third, output falls as lamps age and collect dust. Lighting designers capture the first and third with utilisation and maintenance factors, often 0.4 to 0.6 combined, so a meter in the middle of a typical room may read around half the simple estimate.

Comparing against a target

Standards such as EN 12464-1 give target illuminances: 500 lux for desk work, 300 lux for many general tasks, 100 lux for corridors. Divide your lamp lumens by the area, apply a realistic loss factor and compare. If you fall short, either add lamps or work backwards with the lux to lumens converter to find the lumens you need. The light converter hub does the room calculation with the standard's values.

Beams and spotlights

Dividing by area suits lamps that light a whole room. For a spotlight aimed at one spot, the light is not spread over the room at all; use the beam's intensity instead. The lumens to candela converter gives the intensity from the beam angle, and the candela to lux converter the illuminance at a distance.

Summary

Lux is lumens divided by square metres. The answer is an upper average for the area; expect less on a meter, and more directly under the lamp. Use foot-candles where your plans are in feet.

More questions

Why is the lux right under a lamp higher than the average?

Light from a single lamp is concentrated below it and spreads thinner towards the walls. Dividing lumens by area gives the average across the whole surface; directly under a downlight the illuminance can be several times that, and in the corners well below it. Several smaller lamps spread evenly give a more uniform result.

Is a lumens-to-lux estimate good enough for a workplace assessment?

No. It is a quick average that ignores losses and uniformity. A workplace check measures maintained illuminance at task height on a grid of points with a calibrated meter, or uses lighting design software with the actual fittings and room surfaces.

How do lumens to lux change with a reflector or lens?

The total lumens stay the same (less a few percent absorbed by the optic), but a reflector or lens confines them to a smaller area. Point an 800-lumen lamp into a 1 m² circle and that circle gets up to 800 lux; for a beam, the candela to lux page with the distance gives a better estimate.

What is the lux from a 1,000 lumen bulb in a 10 m² room?

100 lux as an upper average, if every lumen reached the floor. Expect roughly half that in a typical room once the fitting, walls and ceiling have absorbed their share.

Can I use lumens to lux for plants?

Only roughly. Plants respond to photosynthetic photon flux (µmol/m²/s), which counts photons rather than weighting light by the human eye. Lux undervalues red and blue light that plants use well, so grow-light makers quote PPFD instead.

Sources

This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.

Spotted a wrong result or a bug? Report a problem

May we count your visits with Invoker Analytics? It keeps a random visitor number in your browser. Your calculator inputs are never sent. Privacy policy