mcd to Lumens: Converting LED Millicandela Ratings to Light Output
By FindMySum · Last reviewed
mcd to lumens converts the brightness figure on an LED datasheet into the total light the LED emits. Small LEDs, such as indicator lamps and 5 mm through-hole parts, are usually rated in millicandela (mcd): thousandths of a candela, measured straight along the LED's axis. Lumens count all the light in every direction. To get from one to the other you need the LED's viewing angle, which tells you how widely the light spreads.
The formula
First turn millicandela into candela by dividing by 1,000. Then multiply by the solid angle of the viewing cone:
lumens = (mcd ÷ 1,000) × 2π(1 − cos(θ ÷ 2))
The converter opens with a 20,000 mcd LED with a 30° viewing angle, typical of a bright water-clear 5 mm part:
- 20,000 mcd = 20 cd
- Ω = 2π × (1 − cos 15°) = 0.2141 sr
- 20 cd × 0.2141 sr = 4.28 lumens
Twenty thousand sounds like a lot, but because the light is packed into a narrow cone, the total is only about four lumens: roughly a two-hundredth of a household bulb.
Why the viewing angle matters so much
Intensity measures light per steradian. Spread the same lumens over a wider cone and the intensity drops; narrow it and the intensity climbs. That is why datasheet mcd values vary so widely between LEDs with similar chips:
| Viewing angle | Solid angle | 1,000 mcd is |
|---|---|---|
| 15° | 0.0538 sr | 0.054 lm |
| 30° | 0.2141 sr | 0.214 lm |
| 60° | 0.8418 sr | 0.842 lm |
| 120° | 3.1416 sr | 3.14 lm |
A diffused LED rated at 1,000 mcd over 120° gives about fifteen times the light of a water-clear one rated at 1,000 mcd over 30°.
Why the answer is an upper estimate
The formula assumes the intensity is the same everywhere inside the viewing angle. Datasheets quote the intensity on the axis, which is the maximum, and define the viewing angle as the cone where intensity has fallen to half of it. Inside that cone the real intensity tapers from 100% to 50%, so the true lumens in the cone are lower than the formula's figure, while a little light spills outside it. For a quick comparison of parts the estimate is fine; if the datasheet also gives luminous flux in lumens, use that.
Read the test conditions
Datasheet mcd values are measured at a stated forward current, often 20 mA for indicator LEDs, and usually at 25 °C. Run the LED at 10 mA and it gives roughly half the light; run it hot and output falls further. The LED resistor calculator sets the current, and the value table on this page shows the lumens for 10 to 10,000 mcd at your viewing angle.
A quick check with two parts
Two red indicator LEDs are rated 2,000 mcd at 30° and 300 mcd at 120°. Converted, the first gives about 0.43 lumens and the second about 0.94 lumens. The second puts out more than twice the light, but the first looks brighter when viewed straight on.
Uniform cone or Lambertian LED
LED datasheets rarely say how the light is spread, so the Beam model menu gives two choices. The default uniform cone treats the millicandela as even across the whole viewing angle, which is the SI link between the units (lm = cd·sr) and the conversion the CIE and NIST definitions give for an even beam. The Lambertian LED option models a flat chip with no lens, whose intensity fades with the cosine of the angle from the axis. Integrating that fall-off over the viewing angle θ gives
lumens = (mcd ÷ 1,000) × π × sin²(θ ÷ 2)
and a bare die radiating over its full front hemisphere (180° or more) gives π lumens per candela. A 1,000 mcd LED with a 120° viewing angle gives about 2.36 lumens as a Lambertian emitter and 3.14 lumens as a uniform cone; at narrow angles such as 30° the two models differ by under 2%. Most 5 mm LEDs have a moulded lens that narrows the beam, so check the polar plot on the datasheet before choosing.
Going the other way
To find the mcd an LED needs for a given light output, divide instead with the lumens to mcd converter. For larger lamps rated in whole candela, the candela to lumens converter works the same way, and the light converter hub has every unit together.
Summary
Lumens are mcd ÷ 1,000 times the solid angle of the viewing cone. Use the full viewing angle from the datasheet, and treat the answer as an upper estimate because mcd is the peak on the axis.
More questions
Why do cheap LED listings quote huge mcd numbers?
Because mcd rewards a narrow beam. A water-clear LED with a 15° viewing angle can show tens of thousands of mcd while producing under a lumen. The number is genuine but says little about total light; convert to lumens with the viewing angle before comparing with LEDs rated in lumens.
What is the difference between 2θ½ and the viewing angle?
They are usually the same thing: 2θ½ is twice the angle from the axis at which intensity falls to half its peak, which manufacturers call the viewing angle. Enter the full value (for example 30°), not the half angle.
How many mcd does an indicator LED need?
For a status light viewed indoors from a metre or two, a few tens to a few hundred mcd is plenty; more can be glaring in a dark room. Sunlight-readable indicators and signs need thousands. Lower the current with a bigger series resistor if an LED is too bright.
Does temperature change an LED's mcd?
Yes. LED output falls as the junction gets hotter, so a datasheet value measured with a short pulse at 25 °C is higher than what the LED gives after warming up in a sealed enclosure. Allow some margin when light output matters.
Can I convert mcd to lux?
Yes, with a distance rather than an angle: divide by 1,000 for candela, then divide by the distance in metres squared. A 20,000 mcd LED gives 20 lux on its axis at 1 m. The candela to lux converter does the second step.
Sources
This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.