Skip to content

Lumens to Watts Converter by Bulb Type (lm to W)

Convert lumens to watts for LED, CFL, halogen or incandescent bulbs, or your own lm/W: watts = lumens ÷ efficacy. With a 10 to 10,000 lumen table.

Calculator Details

800 lumens:10 WSee results ↓

Light output you want, in lumens (800 lm is a 60 W-equivalent bulb)

Sets the luminous efficacy in lumens per watt; choose Custom to type the lm/W of your own lamp

Your Results

800 lumens: 10 W

800 lumens

10 W

using LED (80 lm/W)

Conversion factor

1 lm = 0.0125 W

using LED (80 lm/W)

Luminous efficacy

80 lm/W

LED

800 lumens using LED (80 lm/W) is 10 watts.

Detailed Breakdown

Lumens to watts using LED (80 lm/W)
Lumens (lm)Watts (W)
10 lm0.125 W
30 lm0.375 W
50 lm0.625 W
100 lm1.25 W
300 lm3.75 W
500 lm6.25 W
1,000 lm12.5 W
2,000 lm25 W
5,000 lm62.5 W
10,000 lm125 W

Every row uses the same setting (using LED (80 lm/W)); change it above and the table follows.

800 lumens by lamp type
Lamp typeEfficacyWatts
LED (you)about 80 lm/W10 W
CFL (compact fluorescent)about 57.1429 lm/W14 W
Halogen incandescentabout 17.4419 lm/W45.8667 W
Standard incandescentabout 13.3333 lm/W60 W

How This Calculator Works

How it's calculated

watts = lumens ÷ luminous efficacy (lm/W)

Your numbers: 800 lm ÷ 80 lm/W = 10 W.

Frequently Asked Questions

How do I convert lumens to watts?

Divide the lumens by the lamp’s efficacy in lumens per watt: watts = lumens ÷ lm/W. An 800-lumen LED at 80 lm/W uses 800 ÷ 80 = 10 W; an 800-lumen incandescent at about 13.3 lm/W uses 60 W.

How many watts is 800 lumens?

About 10 W for a typical LED, 14 W for a CFL, 43 W for a halogen and 60 W for a standard incandescent bulb, using the efficacies in this page’s lamp table. The lamp-type table on this page shows all four at once.

Why is there no fixed lumens to watts conversion?

Watts measure electrical power in and lumens measure light out. How much light each watt makes, the luminous efficacy, depends on the technology: LEDs make several times more light per watt than incandescent bulbs, so the lamp type has to be part of the answer.

What is a good lumens per watt figure for an LED?

Many household LED bulbs sold today give around 80 to 120 lm/W, and the best exceed 150 lm/W. The lumens and watts printed on the package give your bulb’s figure: divide one by the other and enter it with Custom.

What is the maximum possible lumens per watt?

683 lm/W, for monochromatic light at 540 THz (green), which is how the SI defines the candela. White light can never reach it; this page caps custom efficacy at 683 lm/W.

How many lumens did a 100 W bulb give?

About 1,600 lumens for a standard incandescent, the figure the US FTC Lighting Facts label uses for a "100 W equivalent". A typical LED gives that from about 20 W.

Does a higher wattage LED always mean more light?

Usually, within the same product line, but not across brands or types: compare lumens, not watts. Two 10 W LEDs can differ by 20% or more in output.

Watts and lumens are linked by luminous efficacy (lm/W), which varies by product: these lamp types use typical values, so check the lumens and watts printed on the package, or choose Custom. Not included: driver or ballast losses beyond the rated watts, dimming, and output falling with age. Lamp efficacy: Typical light output per watt for a standard A19 household lamp: incandescent 60 W = 800 lm and the 40/60/75/100 W ≈ 450/800/1,100/1,600 lm equivalence used on the FTC Lighting Facts label (16 CFR Part 305) and US DOE Energy Saver; EISA-compliant halogen 43 W ≈ 750 lm (manufacturer data for the 60 W halogen replacement); CFL 13–15 W for 800 lm (US DOE Energy Saver, 14 W midpoint); LED 80 lm/W, the ENERGY STAR Lamps V2.0/V2.1 minimum efficacy for omnidirectional lamps (CRI < 90). Real products vary; check the lumens and watts on the package.

Results are rounded to 6 significant figures.

Lumens to Watts: How Much Power a Given Brightness Takes

By FindMySum · Last reviewed

Lumens to watts converts a brightness you want into the electrical power a lamp needs to produce it. There is no single conversion factor: watts measure power going in and lumens measure light coming out, and how much light each watt makes depends on the lamp. That ratio is the luminous efficacy, in lumens per watt (lm/W). This guide explains the formula, the typical efficacies the converter uses and how to get an exact figure for your own lamp.

The formula

watts = lumens ÷ luminous efficacy (lm/W)

The converter opens with 800 lumens, the light of a traditional 60 W bulb, and an LED at 80 lm/W:

  • 800 lm ÷ 80 lm/W = 10 W

The lamp-type table on the page repeats the sum for each technology. The same 800 lumens take about 14 W from a compact fluorescent, about 46 W from a halogen and 60 W from a standard incandescent bulb.

Where the efficacy figures come from

The lamp table uses typical values for an ordinary screw-in household lamp, each dated and cited in the page footer:

Lamp typeTypical outputEfficacy
Standard incandescent800 lm at 60 Wabout 13.3 lm/W
Halogen incandescent750 lm at 43 Wabout 17.4 lm/W
Compact fluorescent800 lm at 14 Wabout 57 lm/W
LED800 lm at 10 W80 lm/W

The incandescent figures follow the lumens-to-watts equivalence used on the US Lighting Facts label. The LED figure is the minimum efficacy in the ENERGY STAR Lamps specification for standard omnidirectional lamps, so it is conservative: many LED bulbs sold now give 90 to 120 lm/W, and some more. That is why the converter has a Custom option where you type the efficacy of your own lamp.

Getting an exact answer

Every lamp sold in North America and Europe lists its lumens and its watts. Divide one by the other for that lamp's efficacy, then enter it as Custom. For example, a bulb rated 1,521 lm at 13 W has 117 lm/W; 4,800 lumens of those lamps would draw about 41 W, against 60 W at the table's typical 80 lm/W. For fixtures with a separate driver or ballast, use the fixture's system figures, which include the driver's losses.

The theoretical limit

The SI defines the candela so that monochromatic green light at 540 THz has an efficacy of exactly 683 lm/W. No white light source can reach that, because white light contains colours the eye is less sensitive to. The converter refuses custom figures above 683 lm/W, which catches unit mix-ups.

From watts to running cost

Once you know the watts, the energy follows: watts × hours ÷ 1,000 gives kilowatt-hours. Ten 10 W LEDs on for five hours a day use 0.5 kWh a day, about 183 kWh a year. The electricity cost calculator turns that into money at your rate, and the LED savings calculator compares it with the incandescent or halogen lamps you are replacing.

Going the other way

To find the light a lamp of known wattage gives, multiply instead: lumens = watts × lm/W. The watts to lumens converter does that with the same lamp table, and the light converter hub links watts to lux and room size.

Summary

Watts are lumens divided by efficacy. Pick the lamp type for a typical answer, or read the lumens and watts off your lamp for an exact one. Compare lamps by lumens first and watts second.

More questions

How do I find the lumens per watt of my bulb?

Divide the lumens by the watts printed on the package or the Lighting Facts label. A bulb rated 1,100 lm at 11 W has an efficacy of 100 lm/W. Enter that with the Custom lamp type to get an exact conversion for that product.

Is lumens to watts the same for colour-changing smart bulbs?

Smart bulbs list lumens and watts for white light at full brightness. Coloured light is usually dimmer for the same power, because saturated reds and blues contribute less to lumens, so their efficacy in colour modes is lower than the label figure.

Why do warm-white LEDs need slightly more watts?

Warm-white and high-CRI LEDs use phosphors that convert more blue light to red, and some energy is lost in that conversion. For the same lumens they often draw 5 to 15% more power than cool-white versions of the same product.

How many watts do I need to light a room?

First find the lumens the room needs (target lux × floor area, plus an allowance for losses), then divide by the efficacy. A 12 m² room at 300 lux needs about 3,600 lumens on the floor, or roughly 7,000 lamp lumens with losses: about 90 W of LED at 80 lm/W.

Do lumens to watts figures apply outside North America?

The physics is the same everywhere: watts = lumens ÷ efficacy. Packaging rules differ: the EU energy label also leads with lumens and an efficiency class. The typical efficacies in the lamp table describe common household lamp technologies, which are similar across markets.

Sources

This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.

Spotted a wrong result or a bug? Report a problem

May we count your visits with Invoker Analytics? It keeps a random visitor number in your browser. Your calculator inputs are never sent. Privacy policy