Skip to content

PCB Trace Width Calculator

Calculate the minimum PCB trace width for a current and temperature rise by IPC-2221 or an IPC-2152 fit, for internal or external layers, with resistance and voltage drop.

Calculator Details

Minimum trace width:0.7814 mmSee results ↓

IPC-2221 legacy chart (conservative, what most calculators use) or a published fit to the newer IPC-2152 data

Continuous current through the trace

How much hotter than the board around it the trace may run; 10 °C is a common choice

1 oz/ft² is about 35 µm thick; outer layers are often plated up from ½ oz

External (top or bottom) or internal (buried between layers)

35 µm per oz (default): the metric nominal foil thickness (IEC 61249-5-1) that fabricators’ stack-ups and most trace-width calculators use. IPC-4562A nominal: 34.3 µm per oz (17.1, 34.3, 68.6, 102.9 µm), about 2% thinner, so traces come out about 1.5% wider.

For resistance, voltage drop and power loss

For the trace resistance at its running temperature

Your Results

Minimum trace width: 0.7814 mm

Minimum trace width

0.7814 mm

30.77 mil · external · 1 oz (35 µm)

Cross-section

42.39 mil²

0.02735 mm²

Trace resistance

33.38 mΩ

At 35 °C

Voltage drop

66.76 mV

Power loss 133.5 mW

IPC-2152 fit gives

0.9257 mm

Same current, rise, copper and layer

By IPC-2221, an external trace in 1 oz copper needs to be at least 0.7814 mm (30.77 mil) wide; over its length it drops 66.76 mV and dissipates 133.5 mW.

Compare scenarios

Save these inputs as a scenario, change them, and compare the results side by side.

Loading, available in a moment

Minimum width against current

Minimum width against current

Detailed Breakdown

Minimum width by copper weight (IPC-2221)
CopperExternal (mm)Internal (mm)
½ oz (17.5 µm)1.5634.066
1 oz (35 µm) (you)0.78142.033
2 oz (70 µm)0.39071.016
3 oz (105 µm)0.26050.6776

Widths in mils are the millimetre value ÷ 0.0254.

How This Calculator Works

How It’s Calculated

IPC-2221: I = k · ΔT0.44 · A0.725 (A in mil², k = 0.048 external, 0.024 internal)
IPC-2152 fit: ΔT = 215.3 · I² · W−1.15 · Th−1 (mils) · Width = A ÷ thickness

Your calculation: A = (2 ÷ (0.048 × 10^0.44))^(1/0.725) = 42.393 mil². 1 oz copper is 35 µm (1.378 mil) thick, so the trace must be at least 30.765 mil = 0.78144 mm wide. Over 50 mm at 35 °C its resistance is 33.38 mΩ, dropping 66.76 mV and turning 133.5 mW into heat.

Both methods describe a single trace on a bare board in still air. Copper planes, pours and nearby traces carry heat away and let a trace run cooler; a thin or enclosed board, or many hot traces side by side, make it hotter.

Frequently Asked Questions

How wide should a PCB trace be for 1 amp?

By the IPC-2221 chart, an outer-layer trace in 1 oz copper with a 10 °C rise needs about 0.3 mm (11.8 mil). A 0.3 mm (12 mil) trace is a common choice for signal and light power lines up to about an amp.

How wide should a PCB trace be for 2 amps?

About 0.781 mm (30.8 mil) on an outer layer of 1 oz copper for a 10 °C rise by IPC-2221, or 2.03 mm on an inner layer. Allowing a 20 °C rise brings the outer-layer width down to 0.513 mm.

What is the IPC-2221 trace width formula?

I = k × ΔT^0.44 × A^0.725, where I is the current in amps, ΔT the temperature rise in °C, A the cross-section in square mils, and k = 0.048 for outer layers or 0.024 for inner layers. Solve for A, then divide by the copper thickness to get the width. The constants are a curve fit to the IPC-2221 chart, which dates back to tests in the 1950s.

Is IPC-2221 or IPC-2152 more accurate?

IPC-2152 (2009) is based on newer, better-controlled tests, and IPC-2221C (2023) refers to it for current capacity. Its biggest change is for inner layers, which turned out to cool about as well as outer ones: for 2 A, 1 oz and a 10 °C rise, the IPC-2152 fit gives 0.926 mm against 2.03 mm by IPC-2221. For outer layers at low currents the two are close, and the IPC-2152 fit can be slightly wider.

Why do internal traces need to be wider in IPC-2221?

The original internal-layer chart was made by halving the current allowed for external traces, on the assumption that buried copper cools worse. It was never based on tests of internal traces. IPC-2152 tested them and found they usually run no hotter than outer traces, because the board material conducts heat away on both sides.

Does thicker copper let me use a narrower trace?

Yes: the width needed is roughly the cross-section divided by the thickness. For 2 A at a 10 °C rise on an outer layer, 1 oz copper needs 0.781 mm and 2 oz needs 0.391 mm. Thick copper costs more and limits the finest spacing your board house can etch.

How much voltage does a PCB trace drop?

V = I × R with R = ρ × length ÷ (width × thickness). The default 50 mm, 0.781 mm wide trace in 1 oz copper has about 33.4 mΩ at its running temperature, so 2 A drops 66.8 mV and turns 134 mW into heat. For sense lines and low-voltage rails, size for voltage drop as well as temperature.

What temperature rise should I design for?

A 10 °C rise is a common, conservative choice; 20 °C to 30 °C is often accepted for power traces when the board and parts can take it. Add the rise to the highest ambient inside the enclosure and keep the total below the board material’s rating (often 105 °C to 130 °C for FR-4) with a margin.

Is 1 oz copper 35 µm or 34.3 µm thick?

Both figures are in use, so the calculator lets you choose. 35 µm per ounce is the metric nominal foil thickness most fabricators and calculators use, and it is the default; IPC-4562A gives 34.3 µm. For the default 2 A trace the width is 0.781 mm with 35 µm and 0.797 mm with 34.3 µm. Plating makes finished outer layers thicker than either, so ask your fabricator for the finished copper.

Two labelled methods: the IPC-2221 conductor-sizing chart (IPC-2221B, 2012, Figure 6-4) through its published curve fit, and the Brooks & Adam (2015) fit to the IPC-2152 (2009) data, applied to both layers. IPC-2221C (2023), the edition in force, refers to IPC-2152 for current capacity. Copper thickness is 35 µm per oz/ft² by default (the metric foil nominal, IEC 61249-5-1, used by most fabricators and calculators), with IPC-4562A nominal values (34.3 µm per oz) as a labelled option; resistance uses IEC 60028 annealed copper at ambient plus the temperature rise. It leaves out copper planes and pours, nearby traces, board thickness and material, airflow, altitude, plating and etch tolerances, vias, pulsed or AC current and fusing current. Not a design: confirm critical traces with the standard, your fabricator and a thermal check.

PCB Trace Width Calculator: IPC-2221 and IPC-2152 Width for a Current

By FindMySum · Last reviewed

Current flowing through a copper trace heats it. Make the trace too narrow and it runs hot enough to discolour the board, lift from the laminate or, in the extreme, fuse open. This PCB trace width calculator finds the minimum width for a current and an allowed temperature rise, for inner or outer layers and for ½ to 3 oz copper. It also gives the trace's resistance, voltage drop and power loss over a length you enter.

Two methods, labelled

For decades, designers sized traces from a chart that IPC-2221 inherited from the US military standard MIL-STD-275, based on tests done in the 1950s. A curve fit to that chart is what most online calculators use:

I = k × ΔT^0.44 × A^0.725

where I is the current in amps, ΔT the temperature rise in °C, A the cross-section in square mils, and k = 0.048 for outer layers or 0.024 for inner layers.

In 2009 IPC published IPC-2152, based on new, carefully controlled tests. It gives charts rather than a formula, plus corrections for board thickness, copper planes and other conditions. The newest edition of the general design standard, IPC-2221C (December 2023), no longer carries the old chart and points to IPC-2152 for current capacity.

The calculator offers both methods, clearly labelled:

  • IPC-2221 legacy chart (the default). Conservative for inner layers, familiar, and what most design rules and calculators still use.
  • IPC-2152 fit. Douglas Brooks and Johannes Adam fitted an equation to the IPC-2152 external-trace data in 2015: ΔT = 215.3 × I² × W^−1.15 × Th^−1.0, with width W and thickness Th in mils. The calculator applies it to both layers, since IPC-2152 found inner traces cool about as well as outer ones.

Worked example

The calculator opens with 2 A, a 10 °C rise, 1 oz copper on an outer layer and the IPC-2221 method.

  • 1 oz copper is 35 µm, or 1.378 mil, thick (the default thickness convention).
  • A = (2 ÷ (0.048 × 10^0.44))^(1 ÷ 0.725) = 42.4 square mils.
  • Width = 42.4 ÷ 1.378 = 30.8 mil, or 0.781 mm.

With the IPC-4562A thickness of 34.3 µm (1.350 mil) instead, the same area needs 31.4 mil, or 0.797 mm. On an inner layer, with k = 0.024, the area becomes 110.3 square mils and the width 2.03 mm, more than two and a half times as wide. The IPC-2152 fit gives 0.93 mm for both layers: a little wider than IPC-2221 on the outer layer, much narrower on the inner one.

Resistance and voltage drop

A trace is also a resistor:

R = ρ × L ÷ (W × Th) × (1 + α × (T − 20 °C))

with copper's resistivity ρ = 1/58 Ω·mm²/m (the international annealed copper standard), α = 0.00393 per °C, and T the trace temperature, the ambient plus the rise. A 50 mm long, 0.781 mm wide, 1 oz trace at 35 °C has about 33 mΩ, so 2 A drops 67 mV and dissipates 134 mW. For a 3.3 V rail feeding a processor, or a current-sense connection, that drop can matter more than the temperature: widen the trace or use a plane.

Choosing the temperature rise

The rise is how much hotter the trace runs than the board around it. Ten degrees is a common conservative choice. Power traces are often sized for 20 °C or 30 °C, which allows a much narrower trace: the width falls roughly with the rise to the power 0.6 by IPC-2221. Add the rise to the hottest ambient the board sees and keep the total below the laminate's rating (often 105 °C to 130 °C for FR-4), with a margin.

Copper weight and thickness

Copper is specified by weight per square foot, and two thickness conventions are in use, so the calculator offers both. The default is 35 µm per ounce (17.5, 35, 70 and 105 µm for ½, 1, 2 and 3 oz), the metric nominal foil thickness that fabricators' stack-ups and most trace-width calculators use. The labelled option is the IPC-4562A nominal: 17.1 µm for ½ oz, 34.3 µm for 1 oz, 68.6 µm for 2 oz and 102.9 µm for 3 oz. The IPC values are about 2% thinner, so they give traces about 1.5% wider, the slightly safer answer. Pure copper weighing one ounce per square foot is 34.1 µm thick, so both are rounded nominals. Outer layers are usually plated, so the finished copper is often thicker than the starting foil; your fabricator can tell you the finished thickness.

Reading the chart and table

The chart shows the minimum width for currents from near zero to twice your current, for both layers. The width grows faster than the current because heating goes with the square of the current while the trace's ability to shed heat grows more slowly. The table lists the width for every copper weight on both layers, with your choice marked.

What changes the real temperature

Both methods describe a single trace in still air on a board without copper planes. In a real design:

  • Planes and pours under or near a trace conduct heat away and can lower its temperature a lot.
  • Neighbouring hot traces and components add heat.
  • Thin boards and low-conductivity materials spread heat less well.
  • Enclosures with no airflow raise the ambient.
  • Pulsed current heats a trace by its RMS value, but short pulses let it cool between them.

For critical power paths, use IPC-2152's correction charts or a thermal simulation and measure a prototype. This calculator is a starting point, not a design approval.

More questions

What does copper weight in ounces mean?

It is the mass of copper spread over one square foot of board. One ounce per square foot is 35 µm (1.378 mil) thick by the usual metric nominal, which the calculator uses by default, or 34.3 µm (1.350 mil) by the IPC-4562A nominal value, which you can pick instead. Outer layers usually start as ½ oz foil and are plated up to roughly 1 oz or more during manufacture, so ask your fabricator for the finished thickness.

Can I just use a copper pour instead of a wide trace?

Yes, and it usually runs cooler than a trace of the same width because the large area spreads heat. Watch the narrow necks where a pour squeezes between pads or vias: the current density there sets the hot spot, so check the narrowest point with the calculator.

How much current can a via carry?

A plated via is a short copper tube; its wall cross-section, π × drill diameter × plating thickness, is what carries current. A 0.3 mm via with 25 µm plating has about 0.024 mm² of copper, similar to a 0.7 mm wide 1 oz trace, but it is short, so it heats less. Use several vias in parallel for power connections.

Do traces get hotter on a thin board?

Generally yes. The board itself is the main path heat takes away from a trace, so a thinner board or one with less copper nearby spreads heat less well. The IPC-2152 data were measured on a fairly thick board, and the standard gives correction charts for board thickness and nearby planes.

What is the difference between temperature rise and trace temperature?

Temperature rise is how much hotter the trace runs than its surroundings. The trace temperature is the surroundings plus that rise. A 10 °C rise in a 60 °C enclosure means the trace runs at 70 °C, which still has to stay well below the board material's rated temperature.

Sources

This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.

Spotted a wrong result or a bug? Report a problem