PCB Trace Width Calculator: IPC-2221 and IPC-2152 Width for a Current
By FindMySum · Last reviewed
Current flowing through a copper trace heats it. Make the trace too narrow and it runs hot enough to discolour the board, lift from the laminate or, in the extreme, fuse open. This PCB trace width calculator finds the minimum width for a current and an allowed temperature rise, for inner or outer layers and for ½ to 3 oz copper. It also gives the trace's resistance, voltage drop and power loss over a length you enter.
Two methods, labelled
For decades, designers sized traces from a chart that IPC-2221 inherited from the US military standard MIL-STD-275, based on tests done in the 1950s. A curve fit to that chart is what most online calculators use:
I = k × ΔT^0.44 × A^0.725
where I is the current in amps, ΔT the temperature rise in °C, A the cross-section in square mils, and k = 0.048 for outer layers or 0.024 for inner layers.
In 2009 IPC published IPC-2152, based on new, carefully controlled tests. It gives charts rather than a formula, plus corrections for board thickness, copper planes and other conditions. The newest edition of the general design standard, IPC-2221C (December 2023), no longer carries the old chart and points to IPC-2152 for current capacity.
The calculator offers both methods, clearly labelled:
- IPC-2221 legacy chart (the default). Conservative for inner layers, familiar, and what most design rules and calculators still use.
- IPC-2152 fit. Douglas Brooks and Johannes Adam fitted an equation to the IPC-2152 external-trace data in 2015: ΔT = 215.3 × I² × W^−1.15 × Th^−1.0, with width W and thickness Th in mils. The calculator applies it to both layers, since IPC-2152 found inner traces cool about as well as outer ones.
Worked example
The calculator opens with 2 A, a 10 °C rise, 1 oz copper on an outer layer and the IPC-2221 method.
- 1 oz copper is 35 µm, or 1.378 mil, thick (the default thickness convention).
- A = (2 ÷ (0.048 × 10^0.44))^(1 ÷ 0.725) = 42.4 square mils.
- Width = 42.4 ÷ 1.378 = 30.8 mil, or 0.781 mm.
With the IPC-4562A thickness of 34.3 µm (1.350 mil) instead, the same area needs 31.4 mil, or 0.797 mm. On an inner layer, with k = 0.024, the area becomes 110.3 square mils and the width 2.03 mm, more than two and a half times as wide. The IPC-2152 fit gives 0.93 mm for both layers: a little wider than IPC-2221 on the outer layer, much narrower on the inner one.
Resistance and voltage drop
A trace is also a resistor:
R = ρ × L ÷ (W × Th) × (1 + α × (T − 20 °C))
with copper's resistivity ρ = 1/58 Ω·mm²/m (the international annealed copper standard), α = 0.00393 per °C, and T the trace temperature, the ambient plus the rise. A 50 mm long, 0.781 mm wide, 1 oz trace at 35 °C has about 33 mΩ, so 2 A drops 67 mV and dissipates 134 mW. For a 3.3 V rail feeding a processor, or a current-sense connection, that drop can matter more than the temperature: widen the trace or use a plane.
Choosing the temperature rise
The rise is how much hotter the trace runs than the board around it. Ten degrees is a common conservative choice. Power traces are often sized for 20 °C or 30 °C, which allows a much narrower trace: the width falls roughly with the rise to the power 0.6 by IPC-2221. Add the rise to the hottest ambient the board sees and keep the total below the laminate's rating (often 105 °C to 130 °C for FR-4), with a margin.
Copper weight and thickness
Copper is specified by weight per square foot, and two thickness conventions are in use, so the calculator offers both. The default is 35 µm per ounce (17.5, 35, 70 and 105 µm for ½, 1, 2 and 3 oz), the metric nominal foil thickness that fabricators' stack-ups and most trace-width calculators use. The labelled option is the IPC-4562A nominal: 17.1 µm for ½ oz, 34.3 µm for 1 oz, 68.6 µm for 2 oz and 102.9 µm for 3 oz. The IPC values are about 2% thinner, so they give traces about 1.5% wider, the slightly safer answer. Pure copper weighing one ounce per square foot is 34.1 µm thick, so both are rounded nominals. Outer layers are usually plated, so the finished copper is often thicker than the starting foil; your fabricator can tell you the finished thickness.
Reading the chart and table
The chart shows the minimum width for currents from near zero to twice your current, for both layers. The width grows faster than the current because heating goes with the square of the current while the trace's ability to shed heat grows more slowly. The table lists the width for every copper weight on both layers, with your choice marked.
What changes the real temperature
Both methods describe a single trace in still air on a board without copper planes. In a real design:
- Planes and pours under or near a trace conduct heat away and can lower its temperature a lot.
- Neighbouring hot traces and components add heat.
- Thin boards and low-conductivity materials spread heat less well.
- Enclosures with no airflow raise the ambient.
- Pulsed current heats a trace by its RMS value, but short pulses let it cool between them.
For critical power paths, use IPC-2152's correction charts or a thermal simulation and measure a prototype. This calculator is a starting point, not a design approval.
More questions
What does copper weight in ounces mean?
It is the mass of copper spread over one square foot of board. One ounce per square foot is 35 µm (1.378 mil) thick by the usual metric nominal, which the calculator uses by default, or 34.3 µm (1.350 mil) by the IPC-4562A nominal value, which you can pick instead. Outer layers usually start as ½ oz foil and are plated up to roughly 1 oz or more during manufacture, so ask your fabricator for the finished thickness.
Can I just use a copper pour instead of a wide trace?
Yes, and it usually runs cooler than a trace of the same width because the large area spreads heat. Watch the narrow necks where a pour squeezes between pads or vias: the current density there sets the hot spot, so check the narrowest point with the calculator.
How much current can a via carry?
A plated via is a short copper tube; its wall cross-section, π × drill diameter × plating thickness, is what carries current. A 0.3 mm via with 25 µm plating has about 0.024 mm² of copper, similar to a 0.7 mm wide 1 oz trace, but it is short, so it heats less. Use several vias in parallel for power connections.
Do traces get hotter on a thin board?
Generally yes. The board itself is the main path heat takes away from a trace, so a thinner board or one with less copper nearby spreads heat less well. The IPC-2152 data were measured on a fairly thick board, and the standard gives correction charts for board thickness and nearby planes.
What is the difference between temperature rise and trace temperature?
Temperature rise is how much hotter the trace runs than its surroundings. The trace temperature is the surroundings plus that rise. A 10 °C rise in a 60 °C enclosure means the trace runs at 70 °C, which still has to stay well below the board material's rated temperature.
Sources
- IPC-2221C Generic Standard on Printed Board Design (December 2023), table of contents
- IPC-2152 Standard for Determining Current Carrying Capacity in Printed Board Design (2009), table of contents
- Douglas G. Brooks and Johannes Adam, Trace Currents and Temperatures Revisited (2015)
- Siemens EDA, Copper thickness (IPC-4562A nominal foil thicknesses), 2025
This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.