Skip to content

SWG to mm Converter

Convert SWG (British Standard Wire Gauge) to mm, sq mm and inches, or a diameter in mm to the nearest SWG, with the full 7/0 to 50 SWG chart.

Calculator Details

16 SWG diameter:1.6256 mmSee results ↓

SWG to millimetres, or a diameter or area to the nearest SWG

British Standard Wire Gauge, 7/0 (thickest) to 50. Not the same as AWG.

American wire? AWG to mm converter

AWG sizes differ from SWG: 14 AWG is 1.63 mm, 14 SWG is 2.03 mm.

Your Results

16 SWG diameter: 1.6256 mm

16 SWG diameter

1.6256 mm

0.064 in

Cross-section

2.075 sq mm

π ÷ 4 × d²

Nearest metric cable size (IEC 60228)

2.5 mm²

Next size up: 2.5 mm²

Resistance at 20 °C

0.008307 Ω/m copper

0.01362 Ω/m aluminium · nearest AWG 14

16 SWG wire is 1.6256 mm (0.064 in) in diameter with a cross-section of 2.075 sq mm; the nearest AWG is 14.

Detailed Breakdown

SWG to mm chart: 7/0 to 50 SWG in mm, inches and sq mm
SWGDiameter (mm)Diameter (in)Area (sq mm)Ω/m copperΩ/m aluminium
7/0 SWG12.70.5126.70.00013610.0002231
6/0 SWG11.78560.464109.10.0001580.0002591
5/0 SWG10.97280.43294.560.00018230.0002989
4/0 SWG10.160.481.070.00021270.0003486
3/0 SWG9.44880.37270.120.00024590.0004031
2/0 SWG8.83920.34861.360.0002810.0004606
0 SWG8.22960.32453.190.00032410.0005314
1 SWG7.620.345.60.00037810.0006198
2 SWG7.01040.27638.60.00044670.0007322
3 SWG6.40080.25232.180.00053580.0008784
4 SWG5.89280.23227.270.00063220.001036
5 SWG5.38480.21222.770.00075710.001241
6 SWG4.87680.19218.680.0009230.001513
7 SWG4.47040.17615.70.0010980.001801
8 SWG4.0640.1612.970.0013290.002179
9 SWG3.65760.14410.510.0016410.00269
10 SWG3.25120.1288.3020.0020770.003405
11 SWG2.94640.1166.8180.0025290.004145
12 SWG2.64160.1045.4810.0031460.005157
13 SWG2.33680.0924.2890.004020.00659
14 SWG2.0320.083.2430.0053170.008716
15 SWG1.82880.0722.6270.0065640.01076
16 SWG (yours)1.62560.0642.0750.0083070.01362
17 SWG1.42240.0561.5890.010850.01779
18 SWG1.21920.0481.1670.014770.02421
19 SWG1.0160.040.81070.021270.03486
20 SWG0.91440.0360.65670.026250.04304
21 SWG0.81280.0320.51890.033230.05447
22 SWG0.71120.0280.39730.04340.07115
23 SWG0.60960.0240.29190.059070.09684
24 SWG0.55880.0220.24520.07030.1152
25 SWG0.5080.020.20270.085070.1394
26 SWG0.45720.0180.16420.1050.1722
27 SWG0.41660.01640.13630.12650.2074
28 SWG0.37590.01480.1110.15530.2547
29 SWG0.34540.01360.093720.1840.3016
30 SWG0.3150.01240.077910.22130.3628
31 SWG0.29460.01160.068180.25290.4145
32 SWG0.27430.01080.05910.29170.4782
33 SWG0.2540.010.050670.34030.5578
34 SWG0.23370.00920.042890.4020.659
35 SWG0.21340.00840.035750.48220.7905
36 SWG0.1930.00760.029270.58910.9657
37 SWG0.17270.00680.023430.73591.206
38 SWG0.15240.0060.018240.94521.549
39 SWG0.13210.00520.01371.2582.063
40 SWG0.12190.00480.011671.4772.421
41 SWG0.11180.00440.009811.7582.881
42 SWG0.10160.0040.0081072.1273.486
43 SWG0.09140.00360.0065672.6254.304
44 SWG0.08130.00320.0051893.3235.447
45 SWG0.07110.00280.0039734.347.115
46 SWG0.0610.00240.0029195.9079.684
47 SWG0.05080.0020.0020278.50713.94
48 SWG0.04060.00160.00129713.2921.79
49 SWG0.03050.00120.000729723.6338.74
50 SWG0.02540.0010.000506734.0355.78

Imperial Standard Wire Gauge (BS 3737) diameters, exact in inches. Resistance of solid round wire at 20 °C from resistivity (copper 1/58 Ω·mm²/m, IEC 60028; aluminium 0.028264 Ω·mm²/m, IEC 60889). No current ratings: see your wiring regulations.

How This Calculator Works

How it is calculated

SWG has no formula: each gauge is a fixed diameter in inches (BS 3737); mm = inches × 25.4

area (sq mm) = π ÷ 4 × d² · R (Ω/m) = resistivity ÷ area

Your numbers: 16 SWG = 0.064 in × 25.4 = 1.6256 mm; area = π ÷ 4 × 1.6256² = 2.075 sq mm; copper 0.008307 Ω/m.

Frequently Asked Questions

How do I convert SWG to mm?

SWG has no formula: each gauge is a fixed diameter in inches set in 1883, so look it up and multiply by 25.4. 16 SWG is 0.064 in = 1.626 mm, 18 SWG is 0.048 in = 1.219 mm, 20 SWG is 0.036 in = 0.914 mm and 22 SWG is 0.028 in = 0.711 mm. The chart on this page lists every gauge from 7/0 to 50.

How do I convert mm to SWG?

Find the gauge whose diameter is closest. A 1.2 mm wire is nearest 18 SWG (1.219 mm); a 1 mm wire is nearest 19 SWG (1.016 mm); a 0.5 mm wire is nearest 25 SWG (0.508 mm). Choose “Diameter (mm) → SWG” on the calculator; it also shows the thinnest gauge that is not thinner than your wire.

How do I convert SWG to sq mm?

Work out the area of the circle: π ÷ 4 × d². 16 SWG (1.6256 mm) is 2.075 sq mm, 14 SWG (2.032 mm) is 3.243 sq mm and 18 SWG (1.2192 mm) is 1.167 sq mm. The calculator and the chart show the area for every gauge.

What is the difference between SWG and AWG?

SWG (British Standard Wire Gauge) is a table of fixed sizes used in the UK, India and the Commonwealth; AWG (American Wire Gauge) follows a formula and is used in North America. The same number is a different size: 16 SWG is 1.63 mm but 16 AWG is 1.29 mm. 16 SWG is closest to 14 AWG.

Is SWG still used?

The standard (BS 3737) was withdrawn and new electrical cable is sold in mm², but SWG is still common for enamelled winding wire, jewellery and craft wire, springs, guitar strings, welding rod and sheet metal in some trades, and in older drawings and parts lists.

What does 7/0 SWG mean?

The sizes thicker than 0 are written 2/0, 3/0 up to 7/0 (also 00, 000…). 7/0 SWG is the thickest at 0.500 in (12.7 mm); 50 SWG is the thinnest at 0.001 in (0.0254 mm).

What is the resistance of 22 SWG copper wire?

22 SWG is 0.7112 mm across with an area of 0.397 sq mm, so solid copper is about 0.0434 Ω per metre at 20 °C (resistivity 1/58 Ω·mm²/m). That is useful when winding coils or heating elements; check your wire maker’s figure for enamelled wire.

Which SWG is the same as 2.5 mm² cable?

None exactly: 2.5 mm² is 1.784 mm across, between 16 SWG (1.626 mm, 2.075 mm²) and 15 SWG (1.829 mm, 2.627 mm²). Modern cable is stranded and specified by area, so use the mm² size for wiring and SWG only for solid wire.

SWG diameters are the Imperial Standard Wire Gauge, 7/0 to 50, fixed by Order in Council in 1883 and published as BS 3737:1964 (since withdrawn), checked against a secondary reproduction of the table. Areas are π ÷ 4 × d² for solid round wire; metric sizes are the IEC 60228:2023 nominal areas. Resistance per metre is at 20 °C from resistivity (copper 1/58 Ω·mm²/m, IEC 60028; aluminium 0.028264 Ω·mm²/m, IEC 60889). Not included: the Birmingham (BWG) and Brown & Sharpe gauges (B&S is AWG: see the AWG to mm converter), sheet-metal gauges, current ratings (BS 7671 / your wiring regulations), and enamel or insulation thickness. This is not a design: your electrical code and inspector govern.

SWG to mm Converter: Standard Wire Gauge Chart in mm and sq mm

By FindMySum · Last reviewed

The Standard Wire Gauge (SWG) is the British system for wire sizes, still used in the UK, India and much of the Commonwealth for solid wire: enamelled winding wire for motors and transformers, jewellery and craft wire, springs, fuse wire and welding rod. Unlike the American Wire Gauge, SWG has no formula. Each gauge is a fixed diameter in inches, from 7/0 (half an inch) to 50 (one thousandth of an inch). This converter looks it up both ways: choose a gauge to get its diameter in millimetres and inches, its area in square millimetres and its resistance per metre, or enter a diameter or area in millimetres to find the nearest SWG. The full chart is below the calculator, with a row for every gauge you can link to directly.

How SWG to mm works

Because SWG is a table, converting is a lookup followed by a unit change:

d (mm) = d (inches) × 25.4

and the cross-section of a round wire is

area (sq mm) = π ÷ 4 × d².

Worked example: 16 SWG

The calculator opens at 16 SWG, a common size for fuse wire, tie wire and solid conductors. The table gives 0.064 inch, so

d = 0.064 × 25.4 = 1.6256 mm, and area = π ÷ 4 × 1.6256² = 2.075 sq mm.

Solid copper of that area has a resistance of about 0.0083 Ω per metre at 20 °C, aluminium about 0.0136 Ω per metre. The nearest metric cable size (IEC 60228) is 2.5 mm², and the nearest American gauge is 14 AWG (1.628 mm), which is almost the same wire.

mm to SWG

To go the other way, the calculator finds the gauge with the closest diameter, and also the thinnest gauge that is at least as thick as your wire. A 1.2 mm wire is closest to 18 SWG (1.219 mm). A 1.7 mm wire is closest to 16 SWG (1.626 mm), but if the replacement must not be thinner, 15 SWG (1.829 mm) is the right choice. You can also start from an area: 2.5 sq mm corresponds to a 1.784 mm wire, nearest 15 SWG.

SWG and AWG are different

The same number means a different wire in the two systems. 16 SWG is 1.63 mm, but 16 AWG is 1.29 mm; 14 SWG is 2.03 mm, 14 AWG 1.63 mm. As a rough guide, an SWG size is about two numbers thicker than the AWG with the same number in the middle of the range, but the gap changes along the scale. Always check which gauge a drawing, a supplier or a wiring diagram means. The AWG to mm converter covers American sizes.

Resistance figures

Resistance per metre is worked out from the resistivity at 20 °C of annealed copper (1/58 Ω·mm²/m, IEC 60028) and hard-drawn aluminium (0.028264 Ω·mm²/m, IEC 60889), for a solid round wire. Copper's resistance rises by about 0.4% per degree Celsius, so a coil running hot has noticeably more resistance than the chart shows. Enamelled wire makers publish their own tables, which can differ slightly because of tolerances.

What this converter leaves out

Current ratings are not given: for fixed wiring they come from the wiring regulations (BS 7671 in the UK, IS 732 in India, the CEC or NEC in North America) and depend on the installation, not just the size. Sheet metal gauges and the old Birmingham Wire Gauge are different systems and are not included. For circuit design, use the voltage drop calculator and your local code; this page is not a design, and your electrical code and inspector govern.

More questions

Where did the Standard Wire Gauge come from?

It replaced the older Birmingham Wire Gauge, which varied between makers. The British Board of Trade fixed the Imperial Standard Wire Gauge by Order in Council on 23 August 1883, in force from 1 March 1884, and it was later published as British Standard BS 3737:1964.

Why are the SWG steps uneven?

SWG was built from existing trade sizes, so the steps are round numbers in thousandths of an inch rather than a formula: 4 thou between 16 and 19 gauge, 2 thou from 24 to 26, then smaller steps for fine wire. That is why converting SWG needs a table, unlike AWG.

What SWG is 1 mm wire?

19 SWG is 0.040 in, or 1.016 mm, the closest gauge to 1 mm. 20 SWG is 0.914 mm. For a wire that must not be thinner than 1 mm, choose 19 SWG.

Is SWG used for sheet metal thickness?

Sometimes, in the UK and India, but sheet metal gauges are their own systems and differ by material: the US Manufacturers' Standard Gauge for steel, for example, gives 16 gauge as 1.52 mm. Check which gauge a supplier means, or ask for the thickness in millimetres.

What is the SWG of 0.5 mm wire?

25 SWG is 0.020 in, or 0.508 mm, the nearest gauge to 0.5 mm. Its area is about 0.203 sq mm. Fine enamelled winding wire is still commonly ordered by SWG in the UK and India.

Sources

This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.

Spotted a wrong result or a bug? Report a problem

May we count your visits with Invoker Analytics? It keeps a random visitor number in your browser. Your calculator inputs are never sent. Privacy policy