Skip to content

CFM Calculator (Cubic Feet per Minute)

Enter the room's length, width and height in feet and the air changes per hour you want to get the fan size in CFM, or size a bathroom fan by fixtures or a range hood by its width.

Calculator Details

Airflow:115.2 CFMSee results ↓

Airflow for a room, air changes from a fan, a bathroom fan, a range hood, or whole-house ventilation

Metres or feet

Inside length of the room

Inside width of the room

Floor to ceiling

How many times an hour the room’s air is replaced (e.g. 8 for a bathroom, 6–8 for a workshop)

Your Results

Airflow: 115.2 CFM

Airflow

115.2 CFM

54.4 L/s · 196 m³/h

Litres per second

54.4 L/s

Air changes per hour

6.00

Room volume

32.62 m³

1152 ft³

Rated CFM is at a set static pressure; long or narrow ducts and elbows lower real airflow, so pick a fan with some margin and short, smooth ducting.

To change the air 6 times an hour in a 1152 ft³ (32.62 m³) room you need 115.2 CFM (54.4 L/s, 196 m³/h).

Compare scenarios

Save these inputs as a scenario, change them, and compare the results side by side.

Loading, available in a moment

Detailed Breakdown

Your result and ASHRAE 62.2 local exhaust rates
RequirementCFML/sSource
Your result (you)115.254.4Volume × ACH ÷ 60
Bathroom, on demand50.023.6ASHRAE 62.2-2022 Table 5-1
Bathroom, continuous20.09.4ASHRAE 62.2-2022 Table 5-2
Kitchen vented range hood, on demand100.047.2ASHRAE 62.2-2022 Table 5-1
Other kitchen exhaust fan, on demand300.0141.6ASHRAE 62.2-2022 Table 5-1

Check your provincial or local code: some provinces (e.g. Ontario, Quebec) have their own ventilation rules.

How This Calculator Works

How the airflow is calculated

CFM = room volume (ft³) × air changes per hour ÷ 60

1 CFM = 0.4719 L/s = 1.699 m³/h

Your numbers: 1152 ft³ × 6 ÷ 60 = 115.2 CFM.

Frequently Asked Questions

How many CFM for a 12 × 12 room with an 8 ft ceiling?

About 115 CFM for 6 air changes per hour. The room holds 12 × 12 × 8 = 1,152 cubic feet; 1,152 × 6 ÷ 60 = 115.2 CFM, which is 54.4 litres per second. For 4 air changes it would be about 77 CFM.

How big a bathroom fan for a toilet, shower and tub?

150 CFM by the fixture method: 50 CFM each for the toilet, the shower and the tub. For a 12 × 12 ft bathroom that is about 7.8 air changes an hour. The simpler rule of 1 CFM per square foot of floor, with 50 CFM minimum, gives 144 CFM for the same room.

What does the residential code require for a bathroom fan?

The IRC (Table M1505.4.4) requires a bathroom exhaust fan of at least 50 CFM run intermittently or 20 CFM run continuously when the bathroom has no operable window, ducted to the outdoors, never into an attic or crawl space. Many states adopt the code with their own changes.

Does a range hood that moves a lot of air need make-up air?

Under the IRC (M1503.6), a kitchen exhaust hood rated over 400 CFM needs make-up air that is supplied automatically when it runs, because a big hood in a tight house can pull combustion gases back down a water heater or furnace flue. EPA notes that kitchen ventilation is one of the best ways to reduce indoor pollutants from cooking.

Bathroom and range hood sizing from the Home Ventilating Institute; whole-house rates from ASHRAE 62.2-2022 (US) and the National Building Code of Canada 2020 or 2025, Subsection 9.32.3 (Canada; both editions read in NRC’s published text, and their ventilation figures are the same). It leaves out the ASHRAE infiltration credit, provincial codes that differ from the NBC (e.g. Ontario, Quebec, BC Step Code), CSA F326 design for six or more bedrooms, duct pressure losses, make-up air, heat recovery ventilator sizing and commercial ventilation. Your local building official has the final say.

CFM Calculator: Room Air Changes and Bathroom Fan Size (US)

By FindMySum · Last reviewed

This CFM calculator works out fan airflow in cubic feet per minute, the unit printed on every US bathroom fan, range hood and air purifier box. For a room it multiplies the volume in cubic feet by the air changes per hour you want and divides by 60. For a bathroom it adds the allowance for each fixture; for a range hood it uses the hood width and whether it is mounted on a wall or over an island. It also converts the answer to litres per second and cubic metres per hour.

Worked example: air changes in a 12 × 12 ft room

The US page starts in room mode with a room 12 ft by 12 ft with an 8 ft ceiling and a target of 6 air changes per hour.

  1. Volume: 12 × 12 × 8 = 1,152 cubic feet.
  2. Air moved per hour: 1,152 × 6 = 6,912 cubic feet.
  3. CFM: 6,912 ÷ 60 = 115.2 CFM.
  4. Metric: 54.4 L/s, or 196 m³/h.

Switch to bathroom mode with a toilet, a shower and a tub and the fan size is 150 CFM, about 7.8 air changes per hour in the same room.

Air changes, fans and duct runs

A fan's rating is measured at a low static pressure, usually 0.1 inch of water. A long or kinked duct, a flex duct, or a roof cap with a damper lowers the real airflow, so a 110 CFM fan on a long run may only move 70 or 80. Use rigid duct of the size the fan calls for (4 inch for most bath fans, 6 inch or more for hoods), keep runs short and straight, and look for fans rated at 0.25 inch as well. A quiet fan (1 sone or less) is more likely to be used.

Whole-house ventilation

Modern airtight houses need deliberate ventilation for the whole house, not just spot fans. The US energy codes call for mechanical ventilation in new homes, usually sized by ASHRAE 62.2 from the floor area and the number of bedrooms: for a 2,000 square foot, 3-bedroom house that is about 90 CFM continuous. A bath fan run continuously, a heat or energy recovery ventilator, or a supply system can provide it. EPA's indoor air guidance pairs ventilation with source control and filtration as the three ways to cut pollutants.

For sizing in litres per second against the National Building Code of Canada, use the CFM calculator.

Sources

This article explains how the calculator works and is general information, not financial, tax or legal advice. Rules change; check the sources above or a qualified professional before you act.

Spotted a wrong result or a bug? Report a problem

May we count your visits with Invoker Analytics? It keeps a random visitor number in your browser. Your calculator inputs are never sent. Privacy policy