Roof Snow Load Calculator (psf, ASCE 7-22)

Enter the snow depth in inches, the kind of snow and the roof size in feet to get the load in pounds per square foot and the total weight, and compare it with the ASCE 7-22 design load from your ground snow load.

Calculator Details

Snow on the roof now:0.75 kPa (15.6 psf)See results ↓

NBC Part 9 for houses, Part 4 for engineered buildings, ASCE 7-22 in the US

Metres and centimetres, or feet and inches

Fresh powder is light; wet, packed snow and ice are several times heavier

Measured on the roof (or on open ground nearby)

Plan (horizontal) dimension, not along the slope

Plan (horizontal) dimension, eave to eave

Degrees: 4/12 ≈ 18.4°, 6/12 ≈ 26.6°, 8/12 ≈ 33.7°, 12/12 = 45°

Slippery = unobstructed metal or glass where snow slides completely off

From the ASCE Hazard Tool or your building department (ASCE 7-22 risk-category map)

Your Results

Snow on the roof now: 0.75 kPa (15.6 psf)

Snow on the roof now

0.75 kPa (15.6 psf)

18,728 lb over 1200 ft² of roof (76.2 kg/m²)

Code roof snow load

1.01 kPa

21 psf, ASCE 7-22 flat and sloped roof (7.3, 7.4)

Share of the code load

74.3%

Below the code load

Depth that reaches the code load

16.1 in

of settled snow

This is not a structural design. Code values apply to a sound roof built to the code; drifts, valleys, parapets and sliding snow add load, and your building official, local amendments and an engineer govern. Clear snow from the ground with a roof rake, never by climbing on a loaded roof.

12 in of settled snow weighs about 0.75 kPa (15.6 psf), 18,728 lb on the whole roof: 74.3% of the 1.01 kPa (21 psf) roof snow load under ASCE 7-22 flat and sloped roof (7.3, 7.4).

Compare scenarios

Save these inputs as a scenario, change them, and compare the results side by side.

Loading, available in a moment

12 in of snow by type vs the code load

12 in of snow by type vs the code load

Detailed Breakdown

12 in of snow, by type
Snowkg/m³LoadOf code loadDepth at code load
Fresh, dry powder60 (50–70)0.18 kPa / 3.7 psf17.8%67.3 in
Damp new snow150 (100–200)0.45 kPa / 9.4 psf44.6%26.9 in
Settled snow (yours)250 (200–300)0.75 kPa / 15.6 psf74.3%16.1 in
Wind-packed snow375 (350–400)1.12 kPa / 23.4 psf111.5%10.8 in
Wet, heavy or old granular snow500 (400–830)1.49 kPa / 31.2 psf148.6%8.1 in
Ice917 (830–917)2.74 kPa / 57.2 psf272.6%4.4 in

Densities: Paterson, The Physics of Glaciers (1994). Real snow varies; weigh a known volume if it matters.

Code factors used
FactorValueWhy
pg30 psfYour ground snow load
Ce1Exposure
Ct1Thermal
pf21 psf0.7·Ce·Ct·pg
Cs120° roof (warm roof)

How This Calculator Works

How the snow load is calculated

Snow load (kg/m²) = density × depth; kPa = kg/m² × 9.80665 ÷ 1000

ASCE 7-22: pf = 0.7·Ce·Ct·pg; sloped roof ps = Cs·pf

Your numbers: 250 kg/m³ × 12 in = 76.2 kg/m² = 0.75 kPa (15.6 psf). pf = 0.7 × 1 × 1 × 30 = 21 psf; × Cs 1 = 21 psf. The snow now is 74.3% of that.

Frequently Asked Questions

How much does a foot of snow weigh on a roof?

It depends on the snow. A foot of settled snow (about 15.6 lb per cubic foot) weighs about 15.6 psf, so 18,700 lb on a 40 × 30 ft roof. A foot of fresh powder is only about 3.7 psf, while a foot of wet, heavy snow is about 31 psf, 37,000 lb on the same roof.

What is a roof's design snow load in the US?

Building codes use ASCE 7. You start from the ground snow load for your site, pg, set by the code's maps or your local building department, and for a flat or low-slope roof multiply by 0.7 and by the exposure, thermal and importance factors. A ground snow load of 30 psf gives a flat-roof design load of 21 psf with all factors at 1.

Where do I find the ground snow load for my address?

Your local building department sets it, often in its adopted code amendments. ASCE publishes the ASCE 7 Hazard Tool, which gives ground snow loads by address for ASCE 7-22. In mountain areas the maps show case-study regions where the local value must come from the jurisdiction.

When should I worry about snow on my roof?

FEMA's snow load safety guide lists warning signs: sagging ceilings or roof, new cracks in walls or drywall, doors and windows upstairs that suddenly stick, creaking or popping sounds, and water leaks. If you see them, get people out and call a professional; don't climb onto a loaded roof.

Not a structural design: your building official, provincial or municipal amendments and a structural engineer govern. Code rules from the National Building Code of Canada 2020 (the default) or 2025, Division B, Article 9.4.2.2 (Part 9) and Article 4.1.6.2 (Part 4), and ASCE/SEI 7-22 Sections 7.3 and 7.4 (US). NBC 2025 uses 1-in-1,000-year Ss and Sr with a load factor of 1.0, divides the Part 9 load by 1.5, and adds a wind exposure factor from winter temperature and wind speed and a thermal factor CT for Part 4. City Ss and Sr: NBC 2020 Appendix C Table C-2 (checked against the NRC PDF, 2026-11-11) and NBC 2025 Table C-2; use your municipality's figures. Snow densities are typical ranges from Paterson, The Physics of Glaciers. It covers the uniform (balanced) roof load only and leaves out drifts at steps, parapets and projections, valleys, sliding snow, unbalanced gable loads, ice dams, the NBC 2025 Cb = 1 rule for very low roofs, the ASCE 7 minimum roof load and rain-on-snow surcharge, cold-roof slope factors and the strength of your roof.

Which edition applies (CBHCC adoption table, as of 2026-11-11; provinces adopt with amendments):

  • Newfoundland and Labrador: NBC 2025 (since 2026-07-12)
  • British Columbia (BCBC): NBC 2020 (since 2024-03-08)
  • Alberta: NBC 2020 (since 2024-05-01)
  • Saskatchewan: NBC 2020 (since 2024-01-01)
  • Manitoba: NBC 2020 (since 2024-01-01)
  • Ontario (OBC 2024, based on NBC 2020): NBC 2020 (since 2025-01-01)
  • Quebec: NBC 2020 (since 2025-04-17)
  • New Brunswick: NBC 2020 (since 2025-05-01)
  • Nova Scotia: NBC 2020 (since 2025-04-01)
  • Prince Edward Island: NBC 2020 (since 2024-03-31)
  • Yukon: NBC 2020 (since 2023-04-01)
  • Northwest Territories: NBC 2020 (since 2024-10-01)
  • Nunavut: NBC 2015 (since 2018-09-08)

Roof Snow Load Calculator: Pounds per Square Foot (ASCE 7, US)

By FindMySum · Last reviewed

This snow load calculator works out how heavy the snow on a roof is, in pounds per square foot (psf), and compares it with the design snow load a US roof is built for under ASCE 7-22, the standard referenced by the International Building and Residential Codes. The weight comes from the depth of snow and its density, which changes enormously between fresh powder and wet, compacted or icy snow. The design load comes from your site's ground snow load and the roof's exposure, thermal condition and slope.

Worked example: a foot of settled snow on a 40 × 30 ft roof

The US page starts with 12 inches of settled snow on a roof 40 ft by 30 ft with a slope of 20 degrees, a ground snow load of 30 psf and the exposure and thermal factors at 1.

  1. Snow load: 12 inches of settled snow at about 250 kg/m³ is about 15.6 psf.
  2. Total weight: 15.6 psf over 1,200 square feet, about 18,728 lb.
  3. Design load: 0.7 × 30 psf = 21 psf (ASCE 7-22, 7.3).
  4. Comparison: the snow is about 74% of the design load; it would reach the design load at about 16 inches.

With wet, heavy snow the same foot weighs about 31.2 psf, which is 149% of the design load, so the type of snow matters far more than the depth alone.

What a design load means

A roof designed for 21 psf isn't on the edge of collapse when the snow reaches 21 psf. Codes build in load factors and material safety margins, and real roofs often have more capacity. The design load is the snow the roof is meant to carry routinely, and going well past it, especially with drifts against a higher wall or rain on top of snow, is when problems start. Drifts can carry several times the average load in a few feet next to parapets, chimneys and steps in the roof, and the calculator's uniform load doesn't model them.

Clearing snow safely

Use a roof rake from the ground to pull snow off the eaves, which also helps prevent ice dams. Don't shovel a pitched roof yourself or use metal tools on shingles. For flat roofs on garages, barns and commercial buildings, hire a contractor with fall protection. Watch the forecast: the National Weather Service warns when heavy, wet snow or rain on snow is coming.

For snow loads in kilopascals and the National Building Code of Canada climate data, use the snow load calculator.

Sources

This article explains how the calculator works and is general information, not financial, tax or legal advice. Rules change; check the sources above or a qualified professional before you act.

Spotted a wrong result or a bug? Report a problem

May we count your visits with Invoker Analytics? It keeps a random visitor number in your browser. Your calculator inputs are never sent. Privacy policy