Bernoulli Equation Calculator: Pipe Pressure, Venturi, Pitot and Torricelli
By FindMySum · Last reviewed
Bernoulli's equation describes how a flowing fluid trades pressure for speed and height. Squeeze water through a narrower pipe and it speeds up while its pressure falls; pump it uphill and its pressure drops by about 9.8 kPa for every metre it rises. This Bernoulli equation calculator applies that balance between two points in a pipe, using pipe diameters to find the speeds, and shows the pressure, velocity and elevation heads. It also covers three classic applications: the Venturi flow meter, the Pitot tube and Torricelli's law for a draining tank.
The equation
For steady, incompressible flow with no friction, pumps or turbines between two points:
P₁ + ½ρv₁² + ρgh₁ = P₂ + ½ρv₂² + ρgh₂
- P is the static pressure (use gauge or absolute pressure, but the same at both points)
- ρ is the fluid's density, and ½ρv² its kinetic energy per unit volume
- ρgh is the potential energy per unit volume at height h
The speeds come from the continuity equation, A₁v₁ = A₂v₂: the same volume passes each section every second, so the speed scales with the inverse square of the diameter. Halving the diameter makes the flow four times faster.
Worked example: a reducer and a 5 m rise
The calculator opens with water at 20 °C (998.21 kg/m³) flowing at 2 m/s in a 100 mm pipe at 200 kPa, narrowing to 50 mm at a point 5 m higher.
- v₂ = 2 × (100 ÷ 50)² = 8 m/s
- Kinetic term: ½ × 998.21 × (2² − 8²) = −29,946 Pa
- Height term: 998.21 × 9.80665 × (0 − 5) = −48,946 Pa
- P₂ = 200,000 − 29,946 − 48,946 = 121,108 Pa, or 121.1 kPa
The flow rate is A₁v₁ = 0.007854 m² × 2 m/s = 15.7 L/s. The head table shows the same balance in metres of water: 20.43 m of pressure head plus 0.20 m of velocity head at point 1 equals 12.37 m plus 3.26 m plus the 5 m of elevation at point 2, a total of 20.63 m.
Switch Solve for to flow speed and enter two measured pressures instead: a drop from 200 to 150 kPa across the same reducer at one level means the water is moving at 2.58 m/s before the reducer and 10.3 m/s after it.
The head form
Dividing each term by ρg turns pressures into heights of fluid: pressure head P/(ρg), velocity head v²/(2g) and elevation head h. Their sum, the total head, is constant along a frictionless flow. Pumps are rated in metres of head, and pipe-friction losses are given in metres too, which makes this form the everyday language of pipe design. The stacked chart shows the three heads at each point, with the same total height.
Venturi meters
A Venturi meter narrows the pipe smoothly to a throat and then widens it again. Bernoulli and continuity link the pressure drop at the throat to the flow:
Q = C × A₂ × √(2ΔP ÷ (ρ(1 − β⁴))), β = d₂ ÷ d₁
C is the discharge coefficient, the ratio of real to ideal flow. ISO 5167-4 gives about 0.984 for a classical Venturi tube with an as-cast inlet, 0.995 for a machined one and 0.985 for rough-welded sheet iron. A 50 mm throat in a 100 mm water line showing a 10 kPa difference passes 8.9 L/s. Because the gradual outlet recovers most of the pressure, Venturi meters waste far less energy than orifice plates.
Pitot tubes
A Pitot tube points upstream and brings the fluid to rest at its tip, where the pressure rises by the dynamic pressure ½ρv². Measuring that rise against the static pressure gives v = √(2ΔP ÷ ρ). For air (about 1.2 kg/m³), a 500 Pa difference means 28.9 m/s. Aircraft airspeed indicators, wind tunnels and duct traverses all use the principle.
Torricelli's law
Water leaving a hole near the bottom of an open tank flows as fast as if it had fallen freely from the surface: v = √(2gh). With 2 m of water above the hole, v = 6.26 m/s. The flow rate is Q = C × A × v, and the jet from a sharp-edged hole contracts to about 61% of the hole's area, so C ≈ 0.61; a well-rounded nozzle reaches about 0.98. A 25 mm sharp hole at 2 m depth drains 1.9 L/s at first, slowing as the level falls.
Limits
Bernoulli's equation ignores friction, so in long pipes, valves and fittings the real pressure at point 2 is lower; add those losses with the friction loss calculator, and check the flow regime with the Reynolds number calculator. It does not apply across a pump or turbine without an energy term, to unsteady flow, or to gases whose density changes noticeably, roughly above Mach 0.3. The velocities are averages over the pipe's cross-section.
More questions
Does Bernoulli's principle explain how wings make lift?
Partly. Air flowing over a wing does move faster over the curved upper surface, and its pressure is lower there, which Bernoulli's equation describes. But the common 'equal transit time' explanation is wrong: the air over the top arrives at the trailing edge well before the air underneath. A full explanation also needs the downward deflection of air (Newton's third law) and circulation around the wing.
Why does a shower curtain blow inward?
Several effects contribute: the moving spray drags air along with it and lowers the pressure inside the curtain (a Bernoulli effect), and warm, rising air from hot water sets up a circulation. Simulations suggest a vortex formed by the spray is the main cause.
What is the difference between static, dynamic and stagnation pressure?
Static pressure P is what a gauge flush with the pipe wall reads. Dynamic pressure ½ρv² is the kinetic energy per unit volume of the moving fluid. Stagnation (total) pressure is their sum, the pressure where the flow is brought to rest, as at the tip of a Pitot tube. Their difference gives the speed.
How is Bernoulli's equation related to energy conservation?
Each term is an energy per unit volume: P is the work done by pressure, ½ρv² the kinetic energy and ρgh the gravitational potential energy. Without friction or pumps, energy can only change form, so the sum stays constant along the flow. With friction, a head-loss term is added on the downstream side.
Can I use Bernoulli's equation for air?
Yes, as long as the air's density changes little, which holds for speeds below about a third of the speed of sound, around 100 m/s at room temperature. Ventilation ducts, wind on buildings and low-speed wind tunnels are fine. For faster gas flows, compressible-flow equations are needed.
Why do Venturi meters need a discharge coefficient?
Real flow loses a little energy to friction between the pressure taps, and the velocity is not perfectly uniform across the pipe. The discharge coefficient C, the measured flow divided by the ideal Bernoulli flow, corrects for this. For a classical Venturi tube it is close to 1 (about 0.98 to 0.995), much higher than the roughly 0.6 of an orifice plate, which wastes more energy.
Sources
- OpenStax University Physics Volume 1, §14.6 Bernoulli's Equation
- OpenStax University Physics Volume 1, §14.5 Fluid Dynamics (continuity)
- ISO 5167-4:2022, Measurement of fluid flow by means of pressure differential devices, Part 4: Venturi tubes
- NIST Chemistry WebBook, Thermophysical Properties of Fluid Systems (water density)
This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.