Skip to content

Pump Power Calculator

Calculate pump power from flow and head: hydraulic, shaft and motor input power in kW and hp, total dynamic head with pipe friction, and yearly running cost.

Calculator Details

Pump shaft (brake) power:1.576 kWSee results ↓

Volume pumped per unit time

Work out the total dynamic head from the lift and the pipe, or enter it from a pump curve or test

Height from the supply water level to the discharge point (m); negative if the discharge is lower

Total length of suction and discharge pipe (m)

Internal diameter (mm)

Sets the wall roughness for the friction factor

Sum of loss coefficients: about 0.3 to 0.9 per elbow, 0.2 per open gate valve, 1 for the exit (Crane TP-410)

Water at a temperature, or a custom density and viscosity

0 to 100 °C

From the pump curve at the duty point; 50–85% is typical

From the motor nameplate; premium-efficiency motors are about 90–96%

For the yearly energy and cost

For the yearly energy and cost

Default: Toronto residential average (Hydro-Québec comparison); enter your own rate

Your Results

Pump shaft (brake) power: 1.576 kW

Pump shaft (brake) power

1.576 kW

2.114 hp · 22.52 m total head

Hydraulic (water) power

1.103 kW

1.48 hp delivered to the fluid

Motor input power

1.751 kW

Overall efficiency 63%

Pressure the pump adds

220.7 kPa

32 psi

Yearly energy and cost

$796.20

5,113.7 kWh

Lifting the flow through 22.52 m of head takes 1.103 kW of water power, 1.576 kW (2.114 hp) at the pump shaft and 1.751 kW from the supply, about $796.20 a year to run.

Compare scenarios

Save these inputs as a scenario, change them, and compare the results side by side.

Loading, available in a moment

Where the input power goes

Where the input power goes

Detailed Breakdown

Head and power step by step
StepValue
Static lift15 m
Pipe friction (f = 0.01775, Re = 111,820, turbulent)5.8682 m
Fittings and valves1.6531 m
Total dynamic head22.521 m
Hydraulic power ρgQH1.1033 kW · 1.4795 hp
Shaft power (result)1.5761 kW · 2.1136 hp
Motor input power1.7513 kW · 2.3485 hp

How This Calculator Works

How It’s Calculated

Phydraulic = ρ g Q H · Pshaft = Phydraulic ÷ ηpump · Pinput = Pshaft ÷ ηmotor
H = static lift + f (L/D) v²/2g + ΣK v²/2g

Your calculation: The head is 15 m of lift + 5.868 m of pipe friction + 1.653 m through fittings = 22.521 m. P = 999.1 kg/m³ × 9.80665 m/s² × 0.005 m³/s × 22.521 m = 1,103.3 W. At 70% pump efficiency the shaft needs 1.5761 kW, and at 90% motor efficiency the supply provides 1.7513 kW. Over 2,920 hours a year that is 5,113.7 kWh, or $796.20 at $0.16 per kWh.

Choose a motor rated above the shaft power at the worst duty point (most pumps use more power at higher flow), and check the pump’s net positive suction head before relying on a suction lift.

Frequently Asked Questions

How do you calculate pump power?

Hydraulic power P = ρ × g × Q × H: density × 9.81 × flow in m³/s × head in metres gives watts. 10 L/s of water against 20 m is 1,960 W. Divide by the pump efficiency for the shaft power (2.8 kW at 70%) and by the motor efficiency for the power drawn (3.11 kW at 90%).

How do I calculate pump horsepower in US units?

Water horsepower = gpm × feet of head × specific gravity ÷ 3,960. 100 gpm against 100 ft is about 2.53 hp (the calculator gives 2.527 hp with water at 15 °C). Brake horsepower is that divided by the pump efficiency.

What is total dynamic head?

The total energy per unit weight the pump must add: the static lift plus friction in the pipe plus losses in fittings and valves (and any pressure difference between the tanks). The default system has 15 m of lift, 5.87 m of pipe friction and 1.65 m in fittings: 22.5 m in all.

How do I convert pump head to pressure?

Δp = ρ g H. For water, 10 m of head is about 98 kPa (14.2 psi) and 1 psi is about 2.31 ft. Head is used for pumps because a given pump lifts any thin liquid to the same height; the pressure depends on the density. The default 22.5 m is 221 kPa.

What efficiency should I use for a pump?

Read it from the pump curve at your flow and head. Small centrifugal pumps run at 40–70%, large ones at 80–90%. Raising efficiency from 70% to 80% on the default system cuts the shaft power from 1.58 kW to 1.38 kW. A pump far from its best efficiency point wastes energy and wears faster.

How much does it cost to run a pump?

Input power in kW × hours × price per kWh. The default pump draws 1.75 kW; at 8 hours a day all year that is 5,114 kWh, about $796.2 at the default Toronto rate. Pumping energy is often the largest cost over a pump's life, far more than its purchase price.

Does a bigger pipe save pumping energy?

Yes. Friction head falls roughly with the fifth power of the diameter at the same flow. Going from 50 mm to 65 mm pipe on the default system cuts the total head from 22.5 m to 17.2 m and the input power from 1.75 kW to 1.34 kW. The friction loss calculator explores pipe sizing further.

What size motor do I need for my pump?

At least the shaft power at the pump's highest-power operating point, rounded up to the next standard motor size, with margin for wear and fluid changes. Lifting 5 L/s through 10 m takes 0.7 kW at the shaft with a 70% pump. Use the power converter for kW and hp sizes.

Uses P = ρgQH with pump and motor efficiencies (US DOE, Improving Pumping System Performance, 2nd ed.), and the Darcy–Weisbach friction loss with the Colebrook–White friction factor and loss coefficients ΣK (White, Fluid Mechanics; Crane TP-410, 2018). Water properties are from the NIST WebBook; pipe roughness is for new pipe. The default electricity price is the Toronto residential average from the Hydro-Québec 2025 price comparison. It leaves out pump curves and the operating point, net positive suction head and cavitation, pressure differences between tanks, variable-speed drives, demand charges and time-of-use rates, pipe ageing and non-Newtonian fluids. A year of running is days × hours as entered.

Pump Power Calculator: Hydraulic, Shaft and Motor Power, Head and Running Cost

By FindMySum · Last reviewed

A pump turns electricity into moving water. How much power it needs depends on how much water it moves, how high it lifts it, how much friction the pipe adds, and how efficient the pump and motor are. This pump power calculator follows that chain: it works out the total dynamic head from the lift and the pipe (or takes the head you enter), the hydraulic power delivered to the water, the shaft power the pump needs, the power the motor draws, and what running it costs in a year.

Hydraulic power

The power that ends up in the fluid is

P = ρ × g × Q × H

with density ρ in kg/m³, g = 9.80665 m/s², flow Q in m³/s and head H in metres, giving watts. In US units the US Department of Energy's pumping sourcebook gives the same thing as

water horsepower = gpm × feet of head × specific gravity ÷ 3,960

so 100 gpm against 100 ft is about 2.5 hp.

Shaft and motor power

No pump is perfect. The shaft (or brake) power is the hydraulic power divided by the pump efficiency, and the electrical input is the shaft power divided by the motor efficiency:

P_shaft = P_hydraulic ÷ η_pump P_input = P_shaft ÷ η_motor

With a 70% pump and a 90% motor, only 63% of the electricity reaches the water. The chart shows where the rest goes, as heat in the pump and the motor.

Total dynamic head

When you choose "from lift and pipe friction", the calculator adds three parts:

  • Static lift, the height from the supply water level to the discharge point.
  • Pipe friction, from the Darcy–Weisbach equation, hf = f × (L ÷ D) × v² ÷ 2g. The friction factor f comes from the Reynolds number and the pipe roughness: 64 ÷ Re for laminar flow, the Colebrook–White equation for turbulent flow.
  • Fittings and valves, ΣK × v² ÷ 2g, where K is a loss coefficient from tables such as Crane TP-410: roughly 0.3 to 0.9 for an elbow, 0.2 for an open gate valve and 1 for the pipe exit.

Water density and viscosity come from the NIST tables at the temperature you enter; for other liquids, enter a custom density and viscosity.

Worked example

The calculator opens with 5 L/s of water at 15 °C lifted 15 m through 50 m of 50 mm PVC pipe with fittings adding up to ΣK = 5.

  • The water moves at 2.55 m/s, a Reynolds number of about 112,000 (turbulent), giving f = 0.0177.
  • Pipe friction adds 5.87 m and the fittings 1.65 m, for a total head of 22.5 m.
  • Hydraulic power = 999.1 × 9.807 × 0.005 × 22.5 = 1.10 kW.
  • Shaft power at 70% = 1.58 kW (2.11 hp); motor input at 90% = 1.75 kW.
  • Running 8 hours a day all year uses 5,114 kWh, about $796 at the default Toronto residential rate.

Head and pressure

Head and pressure are two ways to state the same energy: Δp = ρ g H. Ten metres of water is about 98 kPa or 14.2 psi. Pump makers quote head because a pump lifts any thin liquid to the same height whatever its density, while the pressure, and the power, scale with density. The calculator shows the pressure the pump adds alongside the head.

Running cost

Energy is usually the largest cost of a pump over its life. The calculator multiplies the input power by your running hours and your electricity price. The default price is an example residential rate; industrial customers often pay less per kWh but face demand charges, so use your own tariff.

Saving energy

The worked example shows where to look:

  • Pipe size: friction head falls roughly with the fifth power of the diameter, so a slightly larger pipe can save a lot of power on long runs.
  • Pump selection: a pump running near its best efficiency point can be 10 to 20 points more efficient than one far from it.
  • Speed control: a variable-speed drive matches the flow to demand instead of throttling.
  • Motor efficiency: premium-efficiency motors save a few percent on every hour of running.

What the calculator leaves out

It takes the efficiencies you enter rather than reading them from a pump curve, so it does not find the operating point where the pump and system curves cross. It ignores pressure differences between closed tanks, net positive suction head and cavitation, pipe ageing, and the correction of pump performance for viscous liquids. Check the selected pump's curve and NPSH before buying.

More questions

What is the best efficiency point of a pump?

The flow at which a centrifugal pump converts shaft power into water power most efficiently, marked on its performance curve. Running near it, typically within 70% to 120% of the best-efficiency flow, saves energy and reduces vibration, seal and bearing wear.

Why does a centrifugal pump use more power at higher flow?

Its power curve usually rises with flow. If the system's resistance falls, for example when a valve opens fully, the pump runs further out on its curve and draws more power. Size the motor for the highest flow the system can reach, not just the design point.

What is NPSH?

Net positive suction head: the pressure margin above the liquid's vapour pressure at the pump inlet. If the available NPSH falls below what the pump requires, the liquid boils in the impeller (cavitation), which erodes it and cuts performance. Long suction lines, high suction lifts and hot water all reduce the margin.

Can I save energy with a variable-speed drive?

Often a lot, when the flow varies. By the affinity laws, flow is proportional to speed and power to roughly the cube of speed, so running at 80% speed needs about half the power. Throttling with a valve wastes the excess head instead.

How is pump power different for oil or other liquids?

Hydraulic power scales with density, so a liquid 20% denser needs 20% more power for the same flow and head. Viscous liquids also raise pipe friction and lower the pump's own efficiency; pump makers publish correction methods (such as the Hydraulic Institute's) for viscous duty.

Sources

This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.

Spotted a wrong result or a bug? Report a problem

May we count your visits with Invoker Analytics? It keeps a random visitor number in your browser. Your calculator inputs are never sent. Privacy policy