Skip to content

Insulation Calculator

Find how much insulation to add to reach the NBC or DOE R-value for your climate zone: depth, number of bags, cost, heat saved and payback for attics, walls and basements.

Calculator Details

Insulation to add:268.6 mmSee results ↓

RSI, mm and m², or R-value, inches and ft²

Attic floor, cathedral ceiling, above-grade wall, floor over an unheated space, or basement wall

The code or DOE value for your zone, or your own target

By heating degree-days: 4 under 3000 (Vancouver), 5 3000–3999 (Toronto), 6 4000–4999 (Ottawa, Montréal), 7A 5000–5999 (Edmonton), 7B 6000–6999, 8 7000+

NBC allows lower values in some zones when the house has an HRV

What is there now

Measured settled depth (mm or inches)

NRCan design values per inch; your product label governs

Area to insulate (m² or ft²)

Area one bag or bundle covers at the depth below (from the label)

Depth the label coverage is for (mm or inches)

Before tax; an example to replace with your store’s price

Installer or blower rental (0 for none)

Your Results

Insulation to add: 268.6 mm

Insulation to add

268.6 mm

Cellulose fibre, blown (settled) to reach RSI 8.67 (NBC 9.36.2 zone 5)

Bags or bundles

60

$1,320.00 of material

Total cost

$1,320.00

Material only

Heating saved a year

$124.00

11.04 GJ (3,068 kWh) of heat

Simple payback

10.6 years

Heat at $11.23 per GJ delivered

Now → after

RSI 2.01 → 8.67

RSI 2.01 → 8.67 · R-11.4 → R-49.23

To reach RSI 8.67 (NBC 9.36.2 zone 5) from RSI 2.01, add 268.6 mm of cellulose fibre, blown (settled): 60 bags. It saves about 11.04 GJ of heat a year, paying back in about 10.6 years.

Compare scenarios

Save these inputs as a scenario, change them, and compare the results side by side.

Loading, available in a moment

Insulation level (RSI)

Insulation level (RSI)

Detailed Breakdown

Depth and bags for each level
LevelRSIAdd (mm)Bags
Target (NBC 9.36.2 zone 5) (you)8.67268.660
NBC with an HRV6.91197.644

Added material: Cellulose fibre, blown (settled), RSI 0.63 per 25.4 mm (NRCan design value).

How This Calculator Works

How it's calculated

Existing RSI = depth × RSI per 25.4 mm · needed = target − existing · depth to add = needed ÷ RSI per mm of the new material

Bags = area × depth ÷ (bag coverage × coverage depth), rounded up

Heat saved = area × (1 ÷ R before − 1 ÷ R after) × degree-days × 24 h

Your numbers: existing 100 mm of glass fibre, loose fill, blown = RSI 2.01; RSI 8.67 − 2.01 = 6.66; ÷ 0.63 per 25.4 mm = 268.6 mm; 60 bags × $22.00 = $1,320.00. Heat saved 11.04 GJ × $11.23/GJ = $124.00 a year.

Frequently Asked Questions

How much attic insulation do I need in Canada?

The National Building Code's minimum for a ceiling below an attic is RSI 6.91 (about R-39) in zone 4, RSI 8.67 (R-49) in zones 5 and 6, and RSI 10.43 (R-59) in zones 7A to 8, without a heat-recovery ventilator. Your province may adopt a different edition or stricter values.

How do I convert RSI to R-value?

Multiply RSI by 5.678 to get the imperial R-value, or divide R by the same number. RSI 8.67 is about R-49.2. RSI is in m²·K/W, R in ft²·°F·h/Btu.

How deep should blown-in insulation be?

Depth = target ÷ value per inch. Blown cellulose is about R-3.6 per inch (RSI 0.63 per 25.4 mm) and blown glass fibre about R-2.9, NRCan's design values. In the example on this page, topping up glass fibre, loose fill, blown to RSI 8.67 needs about 268.6 mm of cellulose. Measure settled depth, and use the label's figure for your product.

How many bags of blown-in insulation do I need?

Bags = area × depth ÷ the coverage printed on the bag (area at a given depth or R-value). With the example's coverage, 100 m² at 268.6 mm takes 60 bags. Enter the coverage from your bag's label: it varies a lot between products.

How much insulation does a basement wall need in Canada?

The National Building Code's minimum for foundation walls is RSI 1.99 in zone 4, RSI 2.98 in zones 5 and 6 and RSI 3.97 in zone 8 without an HRV, effective values for the whole wall. Rigid foam on the inside or outside of the concrete, or a framed wall with batts, can reach them; keep moisture control in mind below grade.

Is adding insulation worth it?

It depends on what is there now. Going from little insulation to the code level saves the most: the example attic saves about 11.04 GJ of heat a year, paying back in about 10.6 years at the default gas price. Each extra inch saves less than the one before, because heat loss falls with 1 ÷ R.

Should I seal air leaks before insulating?

Yes. NRCan and DOE both recommend air sealing the attic floor (around light fixtures, plumbing stacks, the attic hatch and top plates) before adding insulation: air leaking through loose fill carries heat and moisture past it. Keep insulation back from soffit vents with baffles and from recessed lights that are not rated for contact.

Targets: National Building Code of Canada Subsection 9.36.2 minimum effective RSI (Tables 9.36.2.6 and 9.36.2.8, read from the NBC 2015 text as published in the BC Building Code 2018; check the edition your province has adopted, such as Ontario SB-12 or the BC Step Code). Material values: NRCan Keeping the Heat In, Table 3-1. Not a design: your building inspector and your product's label govern. Not included: thermal bridging through framing (the top-up is treated as a uniform layer), vapour and air barriers, ventilation, settling over time, sales tax, and rebates.

Insulation Calculator: How Much Insulation You Need, Bags, Cost and Payback

By FindMySum · Last reviewed

An insulation calculator answers the question every attic top-up starts with: how much do I need to add? This one takes the target for your climate zone from the National Building Code (or a target of your own), subtracts what is already there, and gives the depth to add, the number of bags or bundles, the cost, and an estimate of the heat saved each year and the payback. It works in RSI, millimetres and square metres, or in R-values, inches and square feet.

Step 1: the target

In Canada the reference is Subsection 9.36.2 of the National Building Code, which sets minimum effective thermal resistance by climate zone. The zones follow heating degree-days: zone 4 is under 3,000 (coastal British Columbia), zone 5 is 3,000 to 3,999 (Toronto, southern Ontario), zone 6 is 4,000 to 4,999 (Ottawa, Montréal, Halifax), 7A is 5,000 to 5,999 (Edmonton, Winnipeg) and 7B and 8 are the north. For a ceiling below an attic the minimum rises from RSI 6.91 in zone 4 to 8.67 in zones 5 and 6 and 10.43 from zone 7A, without a heat-recovery ventilator. Houses with an HRV may use slightly lower values in some zones, because the ventilator recovers heat that would otherwise be lost. The calculator also has the code values for cathedral ceilings, above-grade walls, floors over unheated spaces and basement (foundation) walls.

The code values are minimums for new work, and provinces can adopt a different edition or stricter requirements (Ontario's SB-12, Quebec's energy rules, BC's Step Code). Many retrofit programs recommend going beyond them in the attic, where extra depth is cheap. Choose "my own target" for that.

Step 2: what is already there

Measure the depth of the existing insulation in a few places and choose its type. The calculator uses NRCan's design values per 25.4 mm from Keeping the Heat In: blown glass fibre RSI 0.51 (R-2.9 per inch), blown cellulose 0.63 (R-3.6), glass fibre batts 0.56 (R-3.2), mineral fibre batts 0.60, and so on. 100 mm of blown glass fibre is about RSI 2.0 (R-11).

Step 3: depth, bags and cost

The insulation still needed is the target minus the existing value. Dividing by the new material's value per millimetre gives the depth to add. The number of bags is the area times that depth divided by the coverage on the bag's label (an area at a stated depth), rounded up.

Worked example

The calculator opens on a 100 m² attic in zone 5 (no HRV) with 100 mm of old blown glass fibre, topped up with blown cellulose:

  • Target: RSI 8.67 (NBC 9.36.2.6, zone 5). Existing: 100 × 0.51 ÷ 25.4 = RSI 2.01.
  • Needed: 8.67 − 2.01 = RSI 6.66. Cellulose at 0.63 per 25.4 mm: 269 mm to add.
  • Bags: with a bag that covers 4.5 m² at 100 mm, 100 × 268.6 ÷ 450 = 59.7, so 60 bags; at $22 a bag, $1,320.
  • Heat saved: the attic's heat loss falls from 1 ÷ 2.23 to 1 ÷ 8.89 W/m²·K (air films and drywall included). Over 3,800 degree-days that is about 3,070 kWh, or 11 GJ of heat a year: about $124 with natural gas at the default Ontario price and a 95% furnace, so the material pays back in about 11 years.

How the savings are estimated

Heat loss through an assembly is area × ΔT ÷ R. Over a heating season, the sum of the daily temperature differences is the heating degree-days, so the heat saved is area × (1 ÷ R before − 1 ÷ R after) × degree-days × 24 hours. The calculator prices that heat with the fuel, price and efficiency you choose (default prices from the same data as the heat pump calculator). It is a simple steady-state estimate: it ignores solar gains, the attic's real temperature and air leakage, which is why air sealing before insulating matters so much.

Walls, floors and basements

For a framed wall the code value is an effective RSI that includes the studs, which conduct heat far better than insulation. Adding continuous insulation outside the studs (rigid board) raises it most directly; the calculator treats the added layer as uniform, so for wall cavities the real gain is lower. Basement walls follow Table 9.36.2.8, with RSI 1.99 in zone 4 rising to 3.97 in zone 8.

The heat transfer calculator works out the effective RSI of a whole assembly layer by layer, the BTU calculator sizes heating for a room, and the heat pump calculator compares heating fuels.

More questions

What is the difference between nominal and effective RSI?

Nominal RSI is the insulation's own value, the number on the bag. Effective RSI is the whole assembly's, after the studs, joists and other framing that bridge the insulation are accounted for. The National Building Code's 9.36 tables are effective values. For attic fill laid over the joists the two are close; for a framed wall the effective value is well below the batt's nominal rating.

Do I need a permit to add attic insulation?

Usually not for a simple top-up of an existing attic, but rules are set by each province and municipality, and a renovation that opens walls, changes the vapour barrier or adds a room typically needs one. Check with your local building department before starting.

Can I put new insulation on top of old?

Yes, for loose fill and unfaced batts in an attic, as long as the old insulation is dry and free of mould. If it is vermiculite (a grey-brown, pebbly fill), don't disturb it: it may contain asbestos. Have it tested first.

Should I choose cellulose or glass fibre?

Both work for attics. Cellulose has a higher value per inch (about RSI 0.63 per 25.4 mm against 0.51 for blown glass fibre in NRCan's design values) and is denser, so it limits air movement better; glass fibre is lighter and doesn't absorb water. Compare the price per bag with its coverage at your target, which this calculator does.

What are heating degree-days?

A measure of how cold a place is over a heating season: each day adds the number of degrees by which the average temperature falls below 18 °C. Toronto has roughly 3,500 to 4,000, Edmonton about 5,000. Environment and Climate Change Canada publishes them in its climate normals; the calculator uses them to estimate the heat saved.

Sources

This article explains how the calculator works and is general information, not financial, tax, legal or medical advice. Rules change; check the sources above or a qualified professional before you act.

Spotted a wrong result or a bug? Report a problem

May we count your visits with Invoker Analytics? It keeps a random visitor number in your browser. Your calculator inputs are never sent. Privacy policy