Insulation to add:10.5 inSee results ↓

RSI, mm and m², or R-value, inches and ft²

Attic floor, cathedral ceiling, above-grade wall, floor over an unheated space, or basement wall

The code or DOE value for your zone, or your own target

From the DOE / IECC climate zone map: 4 marine and 5 are grouped, as are 7 and 8

DOE gives a range for attics: the low or the high end

What is there now

Measured settled depth (mm or inches)

NRCan design values per inch; your product label governs

Area to insulate (m² or ft²)

Area one bag or bundle covers at the depth below (from the label)

Depth the label coverage is for (mm or inches)

Before tax; an example to replace with your store’s price

Installer or blower rental (0 for none)

Your Results

Insulation to add: 10.5 in

Insulation to add

10.5 in

Cellulose fibre, blown (settled) to reach R 49 (DOE Zone 4 marine and zone 5, R-49 to R-60)

Bags or bundles

55

$990.00 of material

Total cost

$990.00

Material only

Heating saved a year

$141.02

9.55 GJ (2,653 kWh) of heat

Simple payback

7 years

Heat at $14.77 per GJ delivered

Now → after

R 11.58 → 49

RSI 2.04 → 8.63 · R-11.58 → R-49

To reach R-49 (DOE Zone 4 marine and zone 5, R-49 to R-60) from R-11.58, add 10.5 in of cellulose fibre, blown (settled): 55 bags. It saves about 9.55 GJ of heat a year, paying back in about 7 years.

Compare scenarios

Save these inputs as a scenario, change them, and compare the results side by side.

Loading, available in a moment

Insulation level (R)

Insulation level (R)

Detailed Breakdown

Depth and bags for each level
LevelR-valueAdd (in)Bags
Target (DOE Zone 4 marine and zone 5, R-49 to R-60) (you)R-4910.555
High end of the DOE rangeR-6013.571

Added material: Cellulose fibre, blown (settled), R-3.6 per inch (NRCan design value).

How This Calculator Works

How it's calculated

Existing R = depth × R per inch · needed = target − existing · depth to add = needed ÷ R per inch of the new material

Bags = area × depth ÷ (bag coverage × coverage depth), rounded up

Heat saved = area × (1 ÷ R before − 1 ÷ R after) × degree-days × 24 h

Your numbers: existing 4 in of glass fibre, loose fill, blown = R 11.58; R 49 − 11.58 = 37.42; ÷ 3.6 per inch = 10.5 in; 55 bags × $18.00 = $990.00. Heat saved 9.55 GJ × $14.77/GJ = $141.02 a year.

Frequently Asked Questions

What climate zone am I in?

The DOE and the International Energy Conservation Code split the US into zones 1 (hot, southern Florida and Hawaii) to 8 (subarctic Alaska) by county. Most of the Northeast and Midwest is zone 5 or 6, the Southeast zones 2 and 3. DOE's Energy Saver insulation pages include the zone map.

Is there a federal tax credit for insulation?

The Energy Efficient Home Improvement Credit (IRS Form 5695) has covered 30% of the cost of qualifying insulation and air sealing materials, up to an annual limit, but Congress changed the credit in 2025 and it does not apply to property placed in service after December 31, 2025. Check the IRS page for the year you install.

How many inches of insulation is R-38?

It depends on the material: about 10.5 inches of blown cellulose at R-3.6 per inch, or 13 inches of blown fiberglass at R-2.9. Batts reach R-38 in about 12 inches. The bag label lists the settled thickness for each R-value; use it over any rule of thumb.

Do I need to remove old insulation first?

Not usually. New loose fill can go over old if it is dry, free of mold and not vermiculite, which may contain asbestos and should be tested and left undisturbed. Remove insulation that is wet, moldy or contaminated by animals.

What R-value does the US Department of Energy recommend for attics?

DOE recommends R-30 to R-49 in zone 1, R-38 to R-60 in zones 2 and 3, and R-49 to R-60 in zones 4 to 8 for an uninsulated attic. For zone 5, topping up glass fibre, loose fill, blown from R-11.58 to R-49 takes about 10.5 inches of cellulose.

How many inches of blown-in insulation for R-49?

Divide the R-value by the material's R per inch: about 13.6 inches of blown cellulose (R-3.6 per inch) or 16.9 inches of blown fiberglass (R-2.9), using NRCan's design values. Products differ, so check the settled thickness on the bag's coverage chart.

How many bags of blown insulation do I need for 1,000 square feet?

It depends on the depth and the bag. In the example, adding 10.5 inches over 1,000 ft² with bags that cover 48 ft² at 4 inches takes 55 bags. Read the coverage chart on your bag (square feet per bag at each R-value) and enter one line of it.

How much does attic insulation save?

In the example zone 5 attic, going from R-11.58 to R-49 saves about 9.55 GJ (2,653 kWh) of heat a year, about $141 with natural gas at the default price, a payback of about 7 years. The less insulation you start with, the more each inch saves.

What R-value should floors over a crawl space have?

DOE suggests R-13 in zones 1 and 2, R-19 in zones 3 and 4 (except marine), R-30 in zone 4 marine, 5 and 6, and R-38 in zones 7 and 8 for floors over unheated spaces such as vented crawl spaces and garages.

How do I convert R-value to RSI?

Divide the R-value by 5.678: R-49 is RSI 8.63. Canada's building code and product labels use RSI (m²·K/W); US labels use R (ft²·°F·h/Btu).

Should I air seal before adding insulation?

Yes. DOE and ENERGY STAR recommend sealing gaps in the attic floor (around lights, wiring, plumbing and the hatch) first, and fitting baffles at the eaves so insulation doesn’t block soffit vents. Air leaking through the fill carries heat and moisture past it.

Targets: U.S. Department of Energy Energy Saver recommended R-values by climate zone (DOE/EE-2476); your state or local energy code governs new work. Material values: NRCan Keeping the Heat In, Table 3-1 (R per inch). Not a design: your building inspector and your product's label govern. Not included: thermal bridging through framing, air sealing, ventilation, settling, sales tax, and utility or tax incentives.

Insulation Calculator (US): R-Value by Zone, Inches and Bags

By FindMySum · Last reviewed

This insulation calculator works the way US homeowners shop: R-values, inches and square feet. Choose your climate zone and it takes the U.S. Department of Energy's recommended R-value for an attic, a floor over a crawl space or garage, or a wood-frame wall, subtracts what you already have, and gives the inches to add, the bags to buy, the cost and the heating dollars saved each year.

DOE recommendations

DOE's Energy Saver guidance recommends R-30 to R-49 for an uninsulated attic in zone 1, R-38 to R-60 in zones 2 and 3, and R-49 to R-60 in zones 4 through 8. For floors over unheated spaces it suggests R-13 in zones 1 and 2, R-19 in zones 3 and 4, R-30 in zone 4 marine and zone 5 and in zone 6, and R-38 in zones 7 and 8. For walls, it suggests filling empty wood-frame cavities (R-13 in the warmest zones, R-20 elsewhere) and adding R-5 to R-10 of continuous insulation when walls are already insulated. The calculator uses the low end of the attic range by default; switch to the high end if you are going further. These are recommendations for existing homes; the energy code your state or city adopts governs new construction and additions.

Worked example: a zone 5 attic

The US page opens on a 1,000 ft² attic in zone 5 with 4 inches of old blown fiberglass, topped up with blown cellulose to R-49:

  • Existing: 4 in × R-2.9 per inch ≈ R-11.6.
  • Needed: R-49 − R-11.6 = R-37.4, which is about 10.5 inches of cellulose at R-3.6 per inch.
  • Bags: with bags that cover 48 ft² at 4 inches, 1,000 ft² at 10.5 inches needs 55 bags; at $18 a bag, $990.
  • Savings: over 6,500 heating degree-days (°F), the heat loss through the ceiling falls by about 2,650 kWh a year, roughly 90 therms of gas. With natural gas at $1.48 a therm and a 95% furnace, that is about $141 a year, a simple payback of about 7 years on the material.

Bags and coverage

Blown insulation is sold by the bag, and every bag's label has a coverage chart: the square feet one bag covers at each R-value and the settled thickness. Enter one line of that chart (area at a depth) and your price; the calculator scales it to the depth you need and rounds up. Machine rental is often free with a minimum bag purchase; enter any installer or rental cost under labor.

Getting the most from a top-up

Seal the attic floor first: gaps around lights, wiring, plumbing stacks, chimneys and the attic hatch let warm, moist air bypass the insulation. Fit baffles at the eaves so the new fill doesn't block soffit vents, keep it away from recessed lights not rated for insulation contact, and insulate and weatherstrip the hatch to the same level. ENERGY STAR's do-it-yourself guide walks through each step.

Sources