Orifice Flow Calculator

Flow through an orifice plate, nozzle or tank outlet from the pressure drop or head: solve for flow, ΔP, diameter or the coefficient of discharge (ISO 5167).

Calculator Details

Flow rate:3.089 L/sSee results ↓

Flow from the pressure drop, the pressure drop for a flow, the orifice size, Cd from a measured flow, or a tank outlet under a head of liquid

Bore of the orifice or nozzle

Pipe the plate sits in; 0 for an orifice in a large tank or wall (no approach velocity)

mm or inches

A typical value for the orifice shape, the ISO 5167-2 equation for a standard orifice plate in a pipe, or your own

Differential pressure across the orifice

L/s, L/min, m³/h, US gpm (3.785 L gallon) or UK gpm (4.546 L imperial gallon)

Liquid water at a temperature, or your own density and viscosity

°C, 0–100

Your Results

Flow rate: 3.089 L/s

Flow rate

3.089 L/s

3.0835 kg/s

Discharge coefficient

0.6088

Orifice plate, flange taps (ISO 5167-2)

Velocity through the orifice

6.2929 m/s

1.5732 m/s in the pipe

Diameter ratio β

0.5

Approach factor E = 1.0328

The orifice passes 3.089 L/s (3.083 kg/s) with Cd = 0.6088.

Compare scenarios

Save these inputs as a scenario, change them, and compare the results side by side.

Loading, available in a moment

Flow against pressure drop

Flow against pressure drop

Detailed Breakdown

Orifice flow values
QuantityValue
Volumetric flow3.089 L/s
Mass flow3.0835 kg/s
Pressure drop50 kPa (5.1077 m head)
Orifice diameter25 mm
Discharge coefficient Cd0.60876
Approach factor E = 1/√(1 − β⁴)1.0328
Velocity through the orifice6.2929 m/s
Fluid density998.21 kg/m³
Pipe Reynolds number78,394.8

How This Calculator Works

How It’s Calculated

Q = Cd × E × A × √(2ΔP ÷ ρ) · A = πd² ÷ 4 · E = 1 ÷ √(1 − β⁴), β = d ÷ D
Tank outlet: Q = Cd × A × √(2gh)
ISO 5167-2: Cd from the Reader-Harris/Gallagher equation, iterated with the pipe Reynolds number

Your calculation: with d = 25 mm, Cd = 0.60876, E = 1.0328 and ρ = 998.21 kg/m³, a pressure drop of 50 kPa gives 3.089 L/s.

Gallons are a named choice, not a silent one: US gpm uses the 3.785 L US gallon and UK gpm the 4.546 L imperial gallon, about 20% larger, so the same flow is a smaller number in UK gpm.

The jet contracts just past a sharp edge (the vena contracta), which is why Cd for a sharp orifice is only about 0.6. For gases, the expansibility factor of ISO 5167 is needed and is not included here.

Frequently Asked Questions

How do you calculate flow through an orifice?

Q = Cd × A × √(2ΔP ÷ ρ), where A is the orifice area, ΔP the pressure drop, ρ the fluid density and Cd the discharge coefficient. A 25 mm sharp-edged orifice with 50 kPa across it passes about 3 L/s of water. In a pipe, multiply by the approach factor 1/√(1 − β⁴).

What is the coefficient of discharge?

The ratio of the real flow to the ideal frictionless flow through the same hole. It is mostly set by how much the jet contracts after a sharp edge (the vena contracta). Typical values: sharp-edged orifice about 0.61, short tube (2–3 diameters long) about 0.8, well-rounded (bell-mouth) entrance about 0.98.

Why does doubling the pressure not double the flow?

Flow grows with the square root of the pressure drop. Raising the drop from 50 to 200 kPa, four times, only doubles the flow through the 25 mm orifice, from 3 to 5.99 L/s. The same square law makes orifice meters lose accuracy at low flows.

What is an orifice plate flow meter?

A thin plate with a precisely machined hole clamped between pipe flanges. Measuring the pressure drop across it gives the flow. ISO 5167-2 standardises the geometry and gives the Reader-Harris/Gallagher equation for Cd: a 25 mm plate in a 50 mm pipe with flange taps has Cd = 0.6088 and passes 3.09 L/s of water at 50 kPa.

What does β (beta ratio) mean?

β is the orifice diameter divided by the pipe diameter. Larger β means the fluid is already moving fast as it approaches, which adds flow (the approach factor 1/√(1 − β⁴)) but makes the meter more sensitive to upstream disturbances. ISO 5167-2 covers β from 0.1 to 0.75.

How long does it take a tank to drain?

The outflow slows as the level falls, because it depends on √h. For a vertical cylindrical tank the time to empty is (tank area ÷ (Cd × orifice area)) × √(2h ÷ g). A 1 m wide tank with 2 m of water over a 25 mm sharp-edged hole starts at 1.88 L/s and takes about 1,675 seconds (under half an hour) to empty, twice as long as it would at the starting flow.

Can I use this for air or gas?

Only for small pressure drops, under a few percent of the upstream pressure. Gases expand as they pass the orifice, so ISO 5167 adds an expansibility factor ε that depends on the pressure ratio and the gas, and choked flow sets in near half the upstream pressure. This calculator treats the fluid as incompressible.

How is this different from the Bernoulli calculator?

The Bernoulli calculator gives the ideal (frictionless) relation between pressure, speed and height, including Torricelli’s free jet and Venturi meters. This page adds the real-world discharge coefficient of an orifice, solves for size or pressure drop, and handles tank drain times.

Incompressible orifice equation (White, Fluid Mechanics §6.12; ISO 5167-1) with water properties from the NIST/IAPWS tables. Orifice-plate Cd uses the Reader-Harris/Gallagher equation of ISO 5167-2:2003 (read through the open-source fluids library documentation; ISO text not read); preset Cd values are typical handbook figures. It leaves out the gas expansibility factor and choked flow, permanent pressure loss, plate thickness and edge sharpness tolerances, pipe roughness and straight-length requirements, cavitation and flashing, and the uncertainty of a real meter.

Orifice Flow Calculator: Flow Rate, Pressure Drop, Size and Discharge Coefficient

By FindMySum · Last reviewed

An orifice is simply a hole that liquid is forced through: a plate clamped in a pipe to measure flow, a restriction that limits it, a nozzle, or the outlet at the bottom of a tank. This orifice flow calculator works out how much liquid passes for a given pressure drop, the pressure drop for a given flow, the hole size you need, or the discharge coefficient from a measurement. For standard orifice plates it uses the Reader-Harris/Gallagher equation of ISO 5167-2, and for tanks it gives the outflow under a head of liquid and the time to drain.

The orifice equation

Bernoulli's equation says that the pressure drop across the hole turns into speed: v = √(2ΔP ÷ ρ). Multiply by the area and you have the ideal flow. Real flow is less, because the jet contracts after a sharp edge and loses a little to friction. The discharge coefficient Cd collects both effects:

  • Q = Cd × E × A × √(2ΔP ÷ ρ)
  • A = πd² ÷ 4, the area of the hole
  • E = 1 ÷ √(1 − β⁴), the approach-velocity factor, with β = d ÷ D for a plate in a pipe of diameter D (E = 1 for a hole in a large tank)

Because flow depends on the square root of the pressure drop, quadrupling the pressure only doubles the flow.

Choosing the discharge coefficient

  • Sharp-edged orifice (about 0.61): the classic thin plate. The jet contracts to roughly 61% of the hole's area.
  • Short tube (about 0.80): a hole through a wall two or three diameters thick. The jet reattaches to the wall, which recovers some flow.
  • Well-rounded entrance (about 0.98): a bell-mouth inlet or a smooth nozzle, with almost no contraction.
  • ISO 5167-2 orifice plate: for a standard concentric plate in a pipe, the Reader-Harris/Gallagher equation gives Cd from β, the pipe diameter, the tap positions and the Reynolds number. Since the Reynolds number depends on the flow, the calculator iterates until they agree.
  • Custom: a value from a manufacturer's data sheet or your own test.

Worked example: an orifice plate meter

The calculator opens with a standard orifice plate: a 25 mm hole in a 50 mm pipe (β = 0.5), flange taps, and water at 20 °C with 50 kPa measured across the taps.

  • area A = π × 0.025² ÷ 4 = 4.909 cm²
  • approach factor E = 1 ÷ √(1 − 0.5⁴) = 1.0328
  • ideal velocity √(2 × 50,000 ÷ 998.2) = 10.0 m/s
  • the ISO equation gives Cd = 0.6088 at a pipe Reynolds number of about 78,000
  • Q = 0.6088 × 1.0328 × 0.000491 × 10.0 = 3.09 L/s, or 11.1 m³/h

A plain sharp-edged hole with no approach correction would be estimated at 3.00 L/s; the difference is a few percent, which matters for metering but not for rough sizing.

Tank outlets and drain time

For a hole in the side or bottom of a tank, the driving pressure is the head of liquid above it, ρgh, so

  • Q = Cd × A × √(2gh)

As the tank drains, h falls and the flow slows. For a vertical cylindrical tank of area A_t the time to empty from a height h is (A_t ÷ (Cd × A)) × √(2h ÷ g), exactly twice what it would take at the starting flow. A 1 m diameter tank with 2 m of water and a 25 mm sharp-edged outlet starts at 1.88 L/s and empties in about 28 minutes.

Solving for the other unknowns

  • Pressure drop: rearranged, ΔP = (ρ ÷ 2) × (Q ÷ (Cd × E × A))². Useful for checking how much pressure a restriction will cost.
  • Diameter: the calculator searches for the hole size that passes your flow at your pressure drop, updating Cd and the approach factor as it goes.
  • Discharge coefficient: measure the flow (with a bucket and stopwatch, or a reference meter) and the pressure drop, and the calculator backs out Cd for your orifice.

Limits

These are incompressible-flow results for liquids. Gases need the ISO 5167 expansibility factor and can choke. The ISO equation is valid only for standard plates within its limits on pipe size (50 mm to 1 m), β (0.1 to 0.75) and Reynolds number, and the calculator flags results outside them. Real meters also need straight pipe upstream and careful installation for their rated accuracy.

More questions

Where should the pressure taps be on an orifice plate?

ISO 5167-2 recognises three arrangements: corner taps right at the faces of the plate, flange taps 25.4 mm (1 inch) either side, and D and D/2 taps one pipe diameter upstream and half a diameter downstream. Each gives a slightly different pressure drop for the same flow, so the discharge coefficient equation changes with the taps. Choose the one your meter uses.

How much straight pipe does an orifice meter need?

Elbows, valves and reducers upstream distort the velocity profile and change the reading. ISO 5167-2 lists minimum straight lengths that grow with β and with the type of fitting, often 10 to 40 pipe diameters upstream and a few downstream. A flow conditioner can shorten them.

What is the permanent pressure loss of an orifice plate?

Part of the measured differential is recovered downstream as the jet slows and spreads again, but much of it is lost to turbulence. For a typical plate the permanent loss is roughly (1 − β²) of the differential, much more than a Venturi tube or a flow nozzle, which is the price of the plate's simplicity and low cost.

Why does Cd change with Reynolds number?

At high Reynolds numbers the jet's contraction is almost fixed by geometry, so Cd levels off near 0.6 for a sharp plate. At lower flows, viscosity thickens the boundary layer at the edge and changes the contraction, so Cd rises. The ISO equation captures this with its Reynolds number terms, which is why the calculator iterates.

How do I size a restriction orifice?

Choose the flow and the pressure drop you want, select the orifice type, and use the diameter mode. For a single-hole restriction plate in a pipe, the ISO sharp-edged equation is a good start; for large pressure drops in liquids, check that the pressure after the plate stays above the vapour pressure or the liquid will cavitate.

What is the vena contracta?

The narrowest point of the jet just downstream of a sharp-edged orifice, roughly half a diameter past the plate. The streamlines cannot turn the corner instantly, so the jet keeps contracting to about 60 to 65% of the hole's area. That contraction is the main reason a sharp orifice has a discharge coefficient near 0.6.